HST20DBPAWH Hotpoint Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- anthony from Hampton, NJ
- Parts Used:
- WR50X10068, WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Defrost cycle would not cycle off
Replaced Defrost Thermostat. Tricky removal of light fixture cover and evaporator cover. Light cover screw removal is not intuiitive and the eveaporator cover tabs are not easy AT ALL to remove.Once they are removed, simply 2 screw removal of rear panel.
Had to unscrew screws holding cooling coils to gain access to thermostat mounted on a coil in rear.
Simkple matter to cut wires, remove old thermostat and splice replacement back on. Found it simpler to re-mount thermostat on top coil greatly simplifying process.(Why didn't they place the original unit in this much more accesible place?)
Re-attach coils to rear wall replace rear panel, light fixture cover and evaporator cover.
Refrigerator has been running fine this past week.
Received parts NEXT DAY! FANTASTIC!
Had to unscrew screws holding cooling coils to gain access to thermostat mounted on a coil in rear.
Simkple matter to cut wires, remove old thermostat and splice replacement back on. Found it simpler to re-mount thermostat on top coil greatly simplifying process.(Why didn't they place the original unit in this much more accesible place?)
Re-attach coils to rear wall replace rear panel, light fixture cover and evaporator cover.
Refrigerator has been running fine this past week.
Received parts NEXT DAY! FANTASTIC!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eileen from Coto de Caza, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
switchlight on my refrigerator was not working
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from West Winfield, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
The fridge was making a clicking sound, and not cooling the food
The back panel was unscrewed, we read the directions with the circuit board and followed them. It was very easy to unplug the old faulty unit and plug in the new replacement part. It was done in 4 minutes flat. Very easy to do yourselves!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christopher from Chicago, IL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Temp panel flashed "hrs", refrigerator would not work
Remove back panel to expose the control board. Simply unplug cables from old board and pull the board out, no tools required. Put new board in place and replace the cables. Very easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Carl from BELLVILLE, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Unit was dead
Removed and replaced control board
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jaime from SYLMAR, CA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
No Cooling on either freezer or refrigerator
Everything seemed to be working right, but no cooling, so I tried turning on and off the switch that turns the light on 5 times within two seconds, refrigerator did not shot. so I removed the main board and I notice a short had taken place on one of the relay legs. I ordered the main board and replaced it. The main board is on the back of the freezer covered with a sheet metal panel about 8"x8" and is secured with hex sheet metal screws. Everything is working now. Please make sure to unplug the unit from power before removing the main board.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from Madison, OH
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Lost Temperature in Refrigerator and Freezer, making clicking noise
Removed main control board cover on back of refrigerator (3 screws). Unplugged power to refrigerator and removed electrical connections to control board using a screwdriver. Using a screwdriver disconnected (4) plastic self -locking prongs holding the board. Matched new replacement board with old board. Plugged in electrical connections to new board. Snapped main control board onto (4) self- locking prongs. Reinstalled cover (3) screws. Plugged in refrigerator and tested refrigerator operation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Purcellville, VA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Fridge evaporator coils frozen
Determined that the defrost heater was bad (didn't test the thermostat or sensor) and attempted to replace it first.
Got the part in one day (super fast shipping).
1) Removed back panel on the inside of the freezer compartment using a nut driver.
2) Removed the ground wire clip from the metal panel
3) Used a screw driver to remove the two philips head screws that hold the heater assembly in place.
4) carefully pulled off the wires attached to the assembly.
5) attached the wires to the new heater
6)attached the new heater and screwed the new heater in place
7) attached the inside panel
8) fridge is now working great.
Got the part in one day (super fast shipping).
1) Removed back panel on the inside of the freezer compartment using a nut driver.
2) Removed the ground wire clip from the metal panel
3) Used a screw driver to remove the two philips head screws that hold the heater assembly in place.
4) carefully pulled off the wires attached to the assembly.
5) attached the wires to the new heater
6)attached the new heater and screwed the new heater in place
7) attached the inside panel
8) fridge is now working great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Marrero, LA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Main Board failed
Part arrived 2 days before anticipated. I was able to keep my fridge running long enough to get the new part in, which took no time at all. The Main Board relay would start clicking and the compressor would shut down. By unplugging the top right plug for a minute and plugging it back in I was able to keep it running for a few hours at a time. Good enough to keep my food from going bad. Thr part was an easy plug in replacement, was a good price, and works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Allen from Smithland, KY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Refigerator quit running
Removed back cover from unit. unpluged wirring harness installed new control board and refigerator runs lik new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Greg from Damon, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Fan was not running to circulate the air; found resistors burned on main board
Removed the board cover from the back, removed old board, installed new board, installed cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rich from san marcos, CA
- Parts Used:
- WR23X21444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No ice from door, but did have water
I got the wrong switch before so just need to put the right 1 in. Super easy, pop off old, plug in new, click back into place. Done. REALLY REALLY EASY for anyone to do
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- lorraine from chula vista, CA
- Parts Used:
- WR13X10285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Socket set
top hinge pin
took down the model number, order here... got sent w/in a few days, couple of bolt/screws done!
Single mom of 6.
Single mom of 6.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Larry from Point Pleasant, NJ
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Freezer iced up, no air circulation
Removed the back panel of the freezer to inspect. The coils were totally iced up. Proceeeded to defrost coils with a heat gun. I then removed the defrost element to insepct and meter reading showed as open (infinite resistance). I ordered a replacement element and it arrive 2 days later. Replace the element and everything worked OK except for the ice maker. It seem that moisture had frozen on the motor impeller for the auger drive motor and locked it up. I removed the drive assembly and defrosted the motor impeller to free it. Everthing now is working fine.
Your blow up drawings made this a very easy repair
Thanks
Your blow up drawings made this a very easy repair
Thanks
Was this instruction helpful to you?