Models > CSX25GPCCWW > Instructions

CSX25GPCCWW Hotpoint Refrigerator - Instructions

Jump to:

All Instructions for the CSX25GPCCWW
61 - 75 of 889
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Barry from Phoenix, AZ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice maker ot making ice
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
18 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arturo from Killeen, TX
Parts Used:
WR02X11561
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
support clip broken.
After figuring out how to remove the old broken clip, replacement was easy. Had to use a small putty knife to open the release on the bottom underside of the clip(between the clip & the refrig) . By looking at the replacement piece it was easy to figure out.
16 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
PERRY from VANDERBILT, MI
Parts Used:
WR60X187
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Wrench set
Noisey Motor, Bearings Out, Dying
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from montgomery, TX
Parts Used:
WR60X10262
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Socket set
ice would not dispense
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new.
thanks.
14 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Northglenn, CO
Parts Used:
WR17X3489
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
This replacement of the light shield was fast and easy. I wish they all good go this smooth.
I repaired as follows. 1) Open freezer door. 2)Removed ice maker bin. 3) removed screw with broken tab on it. 4) install new shield slide to side.
5) Reinstall screw. 6) Grab TAB (tasty adult beverage) and enjoy on back deck while talking about how good you are at repairing stuff.... HA!
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Antelope, CA
Parts Used:
WR55X129
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice Maker Timing was off
The Ice maker would not run through a cycle. It would fill with water and produce ice but would need a little help by pressing up on the ejector to run through its cycle. Otherwise, it would not bring the ice to the holding bend. Sometimes the water would not fill. The icemaker was making ice it just was not letting the ice maker run through its cycle so I figured it had to be the circuit board. I bought the circut board which was easy to install.
1) Turn off water line and unplug power.
2) Pop off front panel plate at ice cube select switch area.
3) Unscrew 4 screws that holds control panel housing in place.
4) Remove panel assembly by disconnecting two different wiring plugs.
5) Unscrew 2 screws that allows access to control circuit board at end cap.
6) Remove circuit board by sliding it out of the assembly housing.
7) Install new circuit control board in assemble housing and screw on end cap retainer.
8) Attach two electrical wiring plugs.
9) Install control board assemble housing into frig opening and secure with 4 screws.
10) Install front panel plate (pops on).
11) Plug in power and turn on water line.
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bennie from Gainesville, FL
Parts Used:
WR13X10020
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
The cam broke apart and the pieces were on the floor. The door did not close automatically. This was on the freezer side.
I used the same steps as described in other descriptions listed here. Since I was changing the hinge assembly on the freezer side the difference I discovered was that there was a nylon water hose inside the hinge assembly that I did not at first know how to remove. I finally called a repairman I happened to know and following his instruction simply snapped the hose loose where there was a connector and placed a cloth under it to catch the moisture that drained. Having done that, the rest of the assembly went just the same way as the other instructions listed here said that it would. Door now functions like new.
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Virginia Beach, VA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper was stuck open. Old and warped.
Replaced flapper
16 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
dwight from phoenix, AZ
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
slow water flow in dispenser
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
14 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Patrick from Medford, NY
Parts Used:
WR9X489
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge wouldn't start
Removed cowling unpluged timer and pluged in new one.
Great Service, got part in one day
12 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Lynnwood, WA
Parts Used:
WR51X443
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator warm / Freezer iced over
I began by turning off the refridgerator and then removing all of the drawers/bins and icemaker from the freezer.

I removed the three phillips-head screws across the top of the rear access panel. (same height as the light bulb) I then removed the two phillips-head screws from the bottom of the access panel.

I removed the access panel by swinging the left side forward to clear the drawer slides, while keeping the right side back against itsattaching points. (Like a door swinging on its hinges.)

I followed the wire harness from the upper heating element up to its connector and unplugged the defrosting heaters from the plug. I then gently removed the little (just smaller than a tea light candle) thermostat from the top of the coils. (Not far from where the wire connector was.)

I removed two phillips head screws for each heater unit and removed the whole thing as on big assembly.

I installed the new parts from the bottom up, careful not to damage anything. I installed the new thermostat carefully and then reconnected the wire harness. Next I reinstalled the access panel, starting twith the top center screw to hold it in place during the installation of the other 4 screws in the corners.

Lastly, I put the drawers / bins and icemaker back in and turned the refrigerator back on. DONE.

It corrected the problem. THANKS for the Great Customer Service, too!
10 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jimmy from Palmer, TN
Parts Used:
WR50X122
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Defrost Thermostat quit working
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marion from Palm Coast, FL
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refridgerator Freezer stoped making ice
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
17 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jack from Copperopolis, CA
Parts Used:
WR24X525
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Frost was accumulating in freezer section.
Loosened screws holding old gasket to door. Removed old gasket. Fit new gasket around strips holding gasket in place---this was not easy. Tightened screws.

New gasket corrected problem.
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laura from Manchester, NH
Parts Used:
WR02X11330
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CSX25GPCCWW
61 - 75 of 889