Cami from Carmel, IN
Parts Used:
WP61001846
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers
Freezer-side cold; Fridge-side warm of side-by-side Refridgerator
evaporator coils were frozen solid and air wasn't flowing across them

read all directions first, then consider which steps you'd like to take

in any case...
- check for blockages in the upper and lower air vents that allow air from freezer side to cool the fridge-side
- inspect that the fan in the freezer side is actually turning and not blocked


- if no blockages and air is flowing between the sides...

- unplug the unit
- remove all goods from freezer and fridge
- remove freezer side racks
- remove rear panel on freezer side using philips screwdriver (note that the ice-cube tray motor housing must be freed by removing its screws. it can be pull out a bit to get to a single screw holding the top of the rear panel in place)
- allow the evaporator coils to evaporate all ice off, checking the drain pan under the fridge frequently - accelerate the process using a hair dryer or paint stripper (heat gun)
- disconnect the white wires from the connection block located about 2/3 of the way up the rear wall and check resistance using an ohmeter (see specs on back of fridge on circuit diagram)
- if you get a very high resistance reading, the heater element is likely broken. if so...
-- remove the 2 metal shields located horizontally across the evaporator coils (behind them are the two series-connected defrost heater elements)
-- visually inspect the elements - if they are discolored green or black, remove and inspect more closely (most likely they are blown, just like a light-bulb filament that shows black on the glass)
-- if you see nothing, remove them anyway (since high reading) and check connectors
-- replace them (likely only $30 to $75, depending on type)

- if coils seem ok, or if not suspect, check the defrost thermostat WHILE IT IS STILL IN A WORKING/COLD FREEZER.
- get the defrost thermostat into a coil chamber (other freezer or bucket of ice?) and check resistance using an ohmeter. It must be WELL-BELOW 40F to test it. When it is truly immersed in cold (as it would be in a working freezer), test the resistance. it should be 0-ohms when <<40F and some much higher resistance (>200KOhms) when > 40F.
- if not, replace it

-lastly, if neither the defrost heater elements are bad nor the defrost thermostat is bad, open up the defrost timer
-- the defrost timer is located in the fridge side, likely with the fridge thermostat knobs/controller
-- it is a 5-pin part that cannot be repaired. If all else is checked, most likely the defrost element is never coming on because the timer is not turning it on
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Douglas from Mesa, AZ
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Condenser fan motor froze up
Unplug fridge, unpluged fan motor from plug socket, removed bracket screws, removed fan retainer clip from shaft. removed screws holding fan to bracket
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Fort Wayne, IN
Parts Used:
WP60100-1
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
Kickplate clip broke off
Reattaching the kickplate clip was easy, but the tab that holds in place was broken. It would slide back when the kickplate was installed. I fashioned a replacement tab out of a piece of 3/32 aluminum bent into a U with the hammer. To hold it in place I drilled and tapped one hole and used a 6-32 machine screw.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from West Ossipee, NH
Parts Used:
D7824706Q
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice Maker Died
When that one came and I went to install it, I found that my fridge was so old (almost 30 years) that the wire harness on the old icemaker could not be transferred to the new one. The old one was hand wired into the guts of the machine with wire nuts and other connectors. The new unit needs a plug in harness to match a plug connection on the ice maker. Also, the bent wire arm that senses ice bin levels was different, old unit hooked in with clips and such, new one pops into a socket in the new ice maker.

I called PartSelect back again, and the clerk spent a lot of time in the books (no parts in the online listings) and found new style connector and wire arm. Another 25 dollars and problem is solved.

Once those parts came, the actual installation was a breeze. Remove three screws, unplug the ice maker from the back wall of the fridge, plug new wire harness into new ice maker and the back wall of the frige, install new ice maker with the same three screws, pop the new style bent wire arm into place and pop the plastic cover from the old ice maker onto the front of the new one. Done! Took me ten minutes (plus two weeks of chasing parts, but only half an hour of actual time in those two weeks).

I let it make a couple of loads of ice that I disposed of (to capture any dust and crud that might have been on or in the new ice maker) and then turned it loose. We had a nice full bin of ice in the morning.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
KEN from FOUNTAIN HILLS, AZ
Parts Used:
D7824706Q
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Original ice maker was leaking
There are 3 screws holding the icemaker in place. After removing the ice bucket, I removed the screws, then twisted the unit to gain access to the power plug. The plug is held in place by a plastic flap which is part of the connector. It has to be pushed down to remove the connector. The new unit went in perfectly and performed flawlessly for 3 days until the compressor blew out! After feeling some sense of accomplishment having fixed the icemaker, I learned that my neglecting to clean the vent grill in the front of the refrigerator had caused its demise. Don't forget to clean the dust out of the vents!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Oak Hill, VA
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Ice Maker Stopped Working
This was a very easy fix. I took the old ice maker out, including the electrical harness. Switched the harness and stop bar to the new ice maker on my bench, then installed the new assembly. Ice initially had some hollow cubes. I checked the ice maker for level. But it was fine. Thought it might be moving too fast. But it seems to have cleared up. Perhaps it took some time to completely cool down.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Gainesville, TX
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Water leaked into ice bin causing big ice chunks
I disconnected power, turned off water supply, removed three hexhead screws, disconnected wiring harness plug, then reversed procedure. New icemaker seens to be a little slower in making cubes. However, the cubes are clean, perfect shape and THEY DO NOT CONTAIN ANY OF THE BLACK COATING AS THE OLD ICE MAKER CAUSED. THIS WAS A FAIRLY SIMPLE TASK.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeannine from Pontiac, IL
Parts Used:
D7824706Q
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice Maker leaking.
I watched the video regarding the instillation of this ice maker a few times and then followed it exactly. It was incredibly easy. We had ice cubes about two hours later and no longer had a leak making icebergs!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GREGG from WEST CHESTER, PA
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice maker was not working.
Ordered new single outlet water valve, received in less than two days. Removed old one, and the repair pretty much feel in place. Instructions were there as a backup. ........ Just curious if the connection from the water source to the valve outlet connection could b a quick connect just the like the water line going directly to the ice maker. Gregg in PA.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Scott from SAN DIEGO, CA
Parts Used:
D7824706Q
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Ice tray was corroded and leaking
Removed top drawer from freezer. Unplugged the ice maker. Uncrewed the bottom screw. Loosened the two top screws. Removed old ice maker. Removed all the parts that didn't come with the new ice maker and installed on new ice maker. Reinstalled the new ice maker. Started making ice with no leaks in about 3 hours.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jack D from CLEBURNE, TX
Parts Used:
WP61001846
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Refrigerator and freezer not cooling as required, compressor running continually
Turned refrigerator and freezer controls to off, removed icemaker bin, unplugged icemaker plug and removed two screws holding icemaker in place and removed icemaker. removed screws holding auger motor and freezer compartment light plate, unplugged and set aside. Remover screws holding freezer coil cover in place and removed cover. Allowed coils to defrost completely and then removed screws that hold the two defrost heater coil mounting plates in place, unplugged the two wires that connect the defrost heater coils to the connector block that is located above the freezer coil. Remove the entire defrost heater by working the connecting wires out from along side the freezer coil. Remove the clips that hold the old defrost heater elements to the mounting plates. Install new heating elements into the two mounting plates with the clips. Reinstall the two mounting plates to brackets on freezer coil and reinstall connecting wiring up to connector block and reconnect them. Reinstall freezer coil cover, icemaker auger motor and freezer compartment light plate, and icemaker and bin to complete job. Due to the confined space in the freezer compartment, reinstalling the freezer coil cover and light plate was difficult as I could only use one arm at a time resulting in many dropped screws.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Lake Wylie, SC
Parts Used:
D7824706Q
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set
icemaker not working
removed screws, pulled element out, and put new element in
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Granite Bay, CA
Parts Used:
D7824706Q
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Leaking water every time ice maker fillls.
Replaced entire ice maker. Turn off water where it comes out of the wall. Loosen two top screws and remove one screw at bottom. Lift unit up and off top screws and swivel out to the right and disconnect power plug from freezer. Warning new unit does not come with: 1. Power Cable 2. Front plastic cover. 3. Wire bail. Install in reverse order Do NOT toss old unit until new one is installed and working. My came with the bottom mounting bracket bent so I just used the old one. When installing old power cable into new unit be sure to put small sensor into clip. It's part of the cable harness assembly.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from MINNEAPOLIS, MN
Parts Used:
4318047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
We would come home from wintering in Texas and the ice maker would again work for about a week. Decided to replace the valve because it wasn't expensive.
Replaced the valve and cleaned all the coils at the same time. The ice maker is spewing out ice. Wife is happy again.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from WAUSAU, WI
Parts Used:
D7824706Q
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Damage to non-stick coating caused water overflow
Repair was as shown in the video except my refrigerator had screws instead of the plastic clips as shown in the video. Just had to loosen the two upper ones and remove the one lower one. All other steps were as shown in the video.