RT11F2WVJA Gibson Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- James from Montross, VA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Freezer dripped water and items thawed but compressor ran.
Instructions from partselect were very clear and probable cause made it easy to narrow things down. I have the manual for the refrigerator that shows the location of the defrost timer. Very surprised that it turned out to be a cheap and easy fix.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Janet from East Wenatchee, WA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Coil, in freezer kept freezing up, refrigerator did not stay cold
Removed the timer, installed the new one. Great service from part select
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Guillermo from Miami, FL
- Parts Used:
- 5303917954
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Freezer iced up, fridge section warm
After reading other posts, I decided to change the defrost thermostat, so I watched the videos, and did that. It got better, but the problem persisted, and the ice was still building up in the freezer section. So I decided that the problem was with the defrost heater. I ordered a new one, that was here under 24hs (using the Fedex ground). I replaced it, measured the old one and saw that it was not passing any current at all (so it was really burnt). Now the fridge is good as new, maintaining the proper temperatures both at Freezer and Fridge sections. Thank you Parts Select ! With $ 70 in parts I was able to get back my appliance working !!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- mark from murrieta, CA
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
the freezer coils were not defrosting so they would ice up and cut off the cold air into the refrigerator side
there were three possible problems the timer, the thermostat, or the heating element.i replaced the timer first as that is the problem 65% of the time and that did not fix the problem, i replaced the thermostat and that did fix the problem. after watching the video on line from parts select i took the back off of the freezer from the inside, defrosted the coils with a hair blower and then swapped out the thermostat which pops right off and i spliced the old connectors to the new thermostat. the heat shrink tubing that came with the part was a little to big so i put a smaller peice on each side for water proofing. that is what the cigarette lighter is for to supply heat to the heat shrink tubing.now that i have fixed that problem i may tackle the ice maker next
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roger from Owatonna, MN
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
It would freeze up or not cool at all, depended where the clock stopped.
Removed the lower trim panel from front of fridg. and loosened two screws enough to turn it about 1/4 inch so the screw heads were in the larger holes. Pulled it out disconnected the wire connector and transfered the heat shield and screws to the new clock, connected the wire connector and aligned the screws. tightened them and job done. Has worked like new sense. Thanks Roger
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from Dunnellon, FL
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
both ref&frez were hot
1 went with maj 69% said defrost timer. NO. 2 went with second choice run cap NO. 3 went with my thought, ( PTC Starter ) why not, most exp part. Fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ed from Glendale, CA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
ice buil up on freezer,not defrosting
first I replaced the timer control hoping thats the problem,unfortunately situation the same ice build up on the freezer.so I replaced the defrost thermostat.right now I'll still observing the condition if still the same.may be in couple days.so far its good.and to replace the parts is not difficult and easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- wayne from marietta, GA
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
fridge not blowing cold
bottom left cornerof fridge defrost timer replaced two bolts and a wire
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Coulee City, WA
- Parts Used:
- 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
the fridge was freezing all the food.
I watched the video you had on-line and it was simple. Thank you so much
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- BILL from GENOA, WV
- Parts Used:
- 5303917954
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jose from brownsville, TX
- Parts Used:
- 5303917954, 215846602
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
The bottom part of the Refrigarater was warm
we removed the food from the freezer, disconnected the fridge , removed the cover, the evaporater fan was running, condeser fan was running, then we checked heater with multimeter and it was ok. next step we replaced the frostimer, and defrost thermostat . and then the refrigarater was working ok, problm was the frost thermastat damaged.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- HUNG from KENT, WA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
refregirator too warm
I order defrost timer then replaced it but it seemed doesn't work. I order defrost thermostat again then it worked fine until now. Thanks. Part selects.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Round Rock, TX
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Weird Noise that continued for at least 60 seconds control OFF.
Unplug the refrigerator. Removed the right hand top shelf. Used a 1/4" nutdriver to remove rear center mounting screw for Control Housing. Used Phillips screwdriver to remove two mounting screws for timer. Unplug cable from timer and plug it into the new timer. Install the new timer and re-install the Control Housing. Plug in the refrigerator and adjust the timer to start the unit. This was a snap with the diagnostic provided by Part Select. At first I thought it was the fan rubbing but when I removed the cover (two screws) it was obvious that wasn't the problem. The diagnostic hinted that it was either the timer or the motor capacitor making the noise. Because the noise continued after turning OFF the control, I thought it was the timer...I was right.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bertha from Lakewood, CA
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Refrigerator warm and freezer defrosting too quickly.
1. Disconnected electrical. 2. Removed upper console in refrigerator by removing 2 nuts. 3. Disconnected wiring from console. 4. Removed 2 screws from defroster timer part and pulled off from connector. 5. Replaced with new defroster timer and put everything back together. Thank you Steve for the U-Tube step by step video.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mainul from Portland, OR
- Parts Used:
- 215846602
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The refrigerator part was not cooling enough
I watched the video online where it described the troubleshooting tips for this type of symptom. So I knew exactly what the problem was which is the defrost timer. After the part came in I just unscrewed (4 screws) the box which houses the thermostat and the defrost timer from top ceiling of the refrigerator section. Then I just unscrewed and unhooked the old defrost timer and replaced it with the new one. After finishing the installation I turned the fridge on. At first nothing happened. So I turned the dial on the defrost timer with a flathead screw until it clicked and the fridge came alive. I waited for an hour or so. The cooling cycle completed and the fridge stopped as expected. When I opened the door I noticed the interior is much colder than before and right after closing the door the fridge hummed back into life again. So I know my fridge is working again. Thanks to PartSelect for providing the right part for my refrigerator. I will definitely buy from them again if anything goes wrong.
Was this instruction helpful to you?
Thank you for voting!