Models > GRT17C2AW0 > Instructions

GRT17C2AW0 Gibson Refrigerator - Instructions

Jump to:

All Instructions for the GRT17C2AW0
31 - 45 of 268
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Amber from SHERMANS DALE, PA
Parts Used:
5303918774
Difficulty Level:
Very Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Socket set
Fan motor no longer functioning and needed to be replaced
The most difficult part was the removal of the existing fan and shroud. There is very little room to work between the condenser and the coils where the fan is located. The old shroud had to be removed as it was not compatible with the mounting for the new fan motor and blade. Make sure to unplug the refrigerator and give the coils some time to cool down. The first step was to remove the old fan blade... it simply pulls off. Next you need to remove the two bolts holding the fan shroud to the floor of the refrigerator. Then you need to remove the old fan motor from the shroud... unplug the wire connection and remove two small bolts that hold it on. I was lucky to have a VERY small ratchet to get into these tight spaces. Now is the really hard part, removing the metal fan shroud takes a lot of twisting and turning to get it out. The coils have a little play in them, but you must be very careful of the tubing and connections. Also, the coils are very sharp. Once this is out, IF you can get it out....I had my doubts along the way, you can start to put the new parts in... beginning with the new fan shroud which fortunately is made of plastic and has some give which makes it easier to get in. Then you can mount the new motor to the shroud with the three new screws. Plug in the wire connection, add the foam tape to the shroud and mount the shroud to the floor of the frig with the original two bolts. Lastly, attach the fan blade. This replacement kit is well constructed, fits perfectly and contained all the necessary parts (fan motor with wiring connection, mounting screws, wire connection adapter, fan shroud, foam tape and fan blade), but no detailed instructions come with it. I was lucky to get the old fan shroud out without doing any damage to the surrounding parts, but this part was very difficult for a do it yourself person. I would be interested to know if a professional has some other tips for this part of the replacement process.
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary from Kenmore, WA
Parts Used:
5303918549
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Food compartment not cooling, freezer working well.
Fantastic!
Sent in a brief description of problem and model number. Reply and description of other customers experiences guided us to the exact problem.
We ordered the part on Friday and it was here on Tuesday.
I prepared the freezer compartment for the removal of the old motor and on Sunday husband installed new Evaporator Fan Motor.

It works and is cooling like it did when it was new.

This has been a great experience as all repairmen wanted at least 60.00 to just come out and determine what the problem was. I can only imagine what the final bill would have been.

This was easy and inexpensive.

Thanks for all the help.
13 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
D KIRKE from CORVALLIS, OR
Parts Used:
5309918806
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Erratic light.
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement switch.
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Amy from PITTSBURGH, PA
Parts Used:
5304464438
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer and refrigerator stopped cooling
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Worcester, MA
Parts Used:
240331502
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Door shelf bar broke
This was a really simple repair. The hardest part was getting the broken piece of the plastic end cap out of the metal retainer bar. I had to use a small screwdriver to gently pry it out of the two notches in the retainer bar. Then I just slipped on the new part, and snapped the whole retainer bar into the fridge door and that was it.

If the end cap doesn't lock into place when you slide it into the metal retainer bar, you may need to bend the bar (gently) to get the notches around the plastic clips. You don't need a lot of force to do this since all you want is to lock the end cap in place.
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from parker, CO
Parts Used:
5303918549
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
8 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karine Lepold /BM CARGO from Miami, FL
Parts Used:
241872501
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Freezer door gasket with a holes
/
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lise from CEDAR GROVE, NJ
Parts Used:
316538904
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Oven light bulb went dark; it needed replacing
Twisted replacement bulb into place easily. Let there be light!
9 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Denver from BLAIRSVILLE, GA
Parts Used:
5303918549
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from McBee, SC
Parts Used:
5303918774
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Freezer compartment warm / Ice cream soft
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now.
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Austin, TX
Parts Used:
240311502, 240311501
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Door retainer bar end broke
The plastic ends are held to the retainer bar by small metal tabs in the retainer bar. Pry up the tabs to remove the broken part. Insert the new part and crimp the tabs back down with a pliers. Couldn't be easier.
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brian from Otterville, MO
Parts Used:
5303918202, 215846602
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
freezer frosting over,fridge warm
removed ice maker,,and screws holding back of freezer cover,unplugged wires and removed the cover and fan.wow,only wire to element had come unplugged!went ahead and replaced thermostat,and defrost timer,both were easy to do
8 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from Cedar Park, TX
Parts Used:
215846602
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
unit quit cooling
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Catherine from Bismarck, ND
Parts Used:
240337712, 240331401, 240311502, 240311501
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Refrigerator door missing parts
I ordered two of the long refrigerator shelf door bars and cut one of them to fit the freezer shelf door because that ready-made door bar was very expensive. The fit after cutting and notching to receive the end caps went very well.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Phillip from SUNDANCE, WY
Parts Used:
5303918774
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
fan motor quit working
A little difficult getting out due to restricted space, I took off the fan blade, that gave extra working room. Then it went well going back together,and it all worked as advertised. Thanks. p
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GRT17C2AW0
31 - 45 of 268