TBF21DWE General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Anthony from South Plainfield, NJ
- Parts Used:
- WR60X177
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Socket set
unusually noisy
Removed the three screws from old motor body-bracket assembly , pulled off 1/4'' spade terminals and removed shield from terminal block for re-use.
Removed fan from old unit and installed on new,
screwed new motor in place, replaced terminal wires, plugged back in refrigerator.
Now my old rerfrigerator is whisper quiet
Removed fan from old unit and installed on new,
screwed new motor in place, replaced terminal wires, plugged back in refrigerator.
Now my old rerfrigerator is whisper quiet
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Harold from Teaneck, NJ
- Parts Used:
- WR9X480
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Wrench (Adjustable)
Not cooling because of ice accumulation. But worked if I manually advanced the timer to defrost; waited for defrost; and advanced timer to end defrost. (Once very 6 to 12 hours.)
Turned off and unplugged refrigerator.
Removed 1 screw (Phillips head) to detach old timer and 2 hex head screws to remove bracket from "beam" in front (bottom) of "fridge"and detach grounding wire. (Slightly difficult to maneuver bracket out of fridge.
Disconnected 4 wires from old timer and attache them to new one. Replaced (new) timer and bracket. Assumed that separate grounding wire was unnecessary because of cross-wiring between trrminals. (Was I incorrect?)
GE didn't have the timer but PartSelect had a suitable substitute.
It would have been quicker if I knew what I was doing in advance
Removed 1 screw (Phillips head) to detach old timer and 2 hex head screws to remove bracket from "beam" in front (bottom) of "fridge"and detach grounding wire. (Slightly difficult to maneuver bracket out of fridge.
Disconnected 4 wires from old timer and attache them to new one. Replaced (new) timer and bracket. Assumed that separate grounding wire was unnecessary because of cross-wiring between trrminals. (Was I incorrect?)
GE didn't have the timer but PartSelect had a suitable substitute.
It would have been quicker if I knew what I was doing in advance
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JACK R from LEESBURG, FL
- Parts Used:
- WR60X177
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Fan Stops - Bad Bearing
Unplug unit from wall. Removed cover from rear of unit. Cleaned coils with vaccuum cleaner. Unplug wires from fan motor and remove nut holding fan blade to motor. Remove 3 screws holding motor to mount. Replace with new motor,make sure fan blade does not hit housing. Plug unit back in wall and replace cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rodney from Lafayette, LA
- Parts Used:
- WR60X177
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Noisy refrigerator.
Remove the 4 screws holding the back cover onto the refrigerator. Unplug the power for the refrigerator. There's 3 bolts holding the fan motor assembly to the refrigerator. Loosen the two bolts which allow the brackets to pivot out , and remove the third bolt. Disconnect the electrical leads, and remove the fan blade, then rotate the fan motor assembly out from the refrigerator. Install mounting brackets from the old motor onto the new motor, then reinstall the assembly in the reverse order of removal.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- T from SOUTHBURY, CT
- Parts Used:
- WR60X30349
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Original evaporator fan (31 years old) was making a lot of worn bearing noise
Empty freezer;
Remove shelves and ice trays;
Unscrew and remove the rear vertical panel;
Unscrew and remove fan housing;
Unscrew and remove fan from fan housing;
Fan blade slides off the motor shaft without tools.
Reverse order to reassemble with new fan motor.
I did have to use the wire extensions that were included as the replacement motor had the electric connections in a different location from the original motor.
Overall, this was an easy replacement.
Remove shelves and ice trays;
Unscrew and remove the rear vertical panel;
Unscrew and remove fan housing;
Unscrew and remove fan from fan housing;
Fan blade slides off the motor shaft without tools.
Reverse order to reassemble with new fan motor.
I did have to use the wire extensions that were included as the replacement motor had the electric connections in a different location from the original motor.
Overall, this was an easy replacement.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marnie from Denver, CO
- Parts Used:
- WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
a fan blade broken causing it to make a loud noise
we took off the old one and replaced it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Woobridge, NJ
- Parts Used:
- WR50X55
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Ice build up in the evaporator coils and had to thaw it out with hair dryer
Cut old thermostat out and installed with heat shrinking wrap and solder the wires and still having issues it might be something else.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ann from LAPORTE, PA
- Parts Used:
- WR60X30349
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
freezer too cold and refrigerator not cold enough because fan not working
Had to defrost a bit and then was able to remove rear freezer panel by simply removing the 2 screws holding it in place.
Old motor easily removed from its mounting bracket. and replaced with the new. Had to use the two wires sent with the motor. I clipped off the male connectors and joined them with wire splicers to the black and red wires clipped from the old motor. Then reinstalled.
The replacement motor works great. I was afraid the old fan blade might not fit but it slid on perfectly.
Old motor easily removed from its mounting bracket. and replaced with the new. Had to use the two wires sent with the motor. I clipped off the male connectors and joined them with wire splicers to the black and red wires clipped from the old motor. Then reinstalled.
The replacement motor works great. I was afraid the old fan blade might not fit but it slid on perfectly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from WILLIAMSPORT, PA
- Parts Used:
- WR60X30349
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Evap fan failed, would need restarted by hand when weather warmed up
Repair was super simple. Everything was a direct fit. Hardest part was unloading freezer to access evap motor. My freezer was old making my wire shields very brittle so I cut the shielding and used heat shrink tubing for a neat clean repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lauraine from Rocky Hill, CT
- Parts Used:
- WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
family member melted fan with hair dryer
Unplugged fridge.Removed 2 screws holding a panel. After panel removed took off old fan and inserted new. Quite simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Cumberland, MD
- Parts Used:
- WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Fan blade broken
Removed the broken fan blade (just pulled off) and replaced with part purchased PartSelect. Very easy repair, no tools required.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- theodore from salisbury, NC
- Parts Used:
- WR60X30349, WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
bad fan motor
take fan out,put new in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edmund from Bethel Park, PA
- Parts Used:
- WR60X177
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Compressor fan bearing worn. Refrigerator was manufactured 9/78/
I followed the instructions verbatim as others explained. I did it step by step exactly as instructed, The timing was almost exact no more than 30 minutes. I removed the fan the night before the delivery of the new fan and used a small desk fan to cool the compressor. It worked fine in one half hour my freezer read a perfect zero. Thanks for all the help
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- joseph from wall, NJ
- Parts Used:
- WR9X480
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Buildup of ice on coil -timer not working
Removed floor grate,romoved screw holding timer,push timer back,removed hex-screw holding bracket,removed ground wire.Removed connectors from old timer and put on new timer,pushed back new timer,mounted bracket,screwed new timer to bracket. Set timer to defrost at 11pm,put back floor grate.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert L. from Eldred, PA
- Parts Used:
- WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Noisy fan
Emptied freezes, turned off power, took floor of freezer out [4 screws ], took two screws out of fan mounts and replaces fan. Reassembled by reverse process. Simple
Was this instruction helpful to you?
Thank you for voting!