door would not stay shut
followed video and completed steps. The video sent with parts e-mail was spot on good job
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from E LONGMEADOW, MA
- Parts Used:
- WD2X5166
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Socket set, Wrench (Adjustable)
water leaking from under dishwasher
Water was leaking from under the GE dishwasher, but once we pulled it out, had apparently been going on for a little while. Turning the water off to the dishwasher made it stop, so it was happening even when the unit was not running, potentially indicating somewhere early in the path of the water to and into the machine.
Indeed, inspecting the water inlet vale showed a slow leak. Getting the replacement part was fine, and it fit the electrical, water inlet (existing 90-degree water inlet elbow), and water outlet connections just fine - but the original machine screws that held on the original water inlet valve did not work. It took a little research to figure out the new type of screw required, which was apparently a 10/16 Type AB, which seemed to be a less common type of sheet metal screw (with a point), as opposed to the original flat-ended machine screws. So, after ordering those separately (which were a bit expensive), it went together fine.
A note on the water inlet valve part just indicating the the threading on those parts has changed over time, so potentially ordering the screws to attach it might be worthwhile, would be good information to add about the water inlet valve.
Indeed, inspecting the water inlet vale showed a slow leak. Getting the replacement part was fine, and it fit the electrical, water inlet (existing 90-degree water inlet elbow), and water outlet connections just fine - but the original machine screws that held on the original water inlet valve did not work. It took a little research to figure out the new type of screw required, which was apparently a 10/16 Type AB, which seemed to be a less common type of sheet metal screw (with a point), as opposed to the original flat-ended machine screws. So, after ordering those separately (which were a bit expensive), it went together fine.
A note on the water inlet valve part just indicating the the threading on those parts has changed over time, so potentially ordering the screws to attach it might be worthwhile, would be good information to add about the water inlet valve.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- George from Hawthorne, NY
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench set
door didn't close on its own..
Removed door off hinge , remove bottom hinge, drill out rivet, lift off old cam & replace with new cam ,add new 1/4' BOLT(NOT SUPPLIED) to location where rivet was, reinstall bottom hinge & door ,check alignment, works perfect.
Thanks
Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Woodland Hills, CA
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set, Wrench (Adjustable)
Fridge door stopped closing.
The plastic door closing cams had broken after 17 years of use. It was tricky figuring out how the new cams fit as the old ones had disintegrated. Also you need 2 cams - not one. I first ordered only one. A detailed parts diagram would have helped. First unscrew the top door mount cover and then the top door mount. The fridge door then lifts up and off the lower door mount. Next is the hardest part - drilling off the old pop rivet which held the lower cam. The lower door mount had to be removed to get at the underneath of the pop rivet, and a bench vise was handy to hold it as I drilled off the old rivet. Then you need small stainless steel nut and bolt and split washer or lock nut to replace the rivet. Next unscrew the old upper cam from the underneath of the fridge door and replace. The large hole in the cam goes through the door hinge pins. The two plastic cams should interlock in a way that makes the door swing close. Anyway, now the door works fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brian from Louisville, KY
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Door had sagged, wouldn't close well.
At first, I noticed the refrigerator door didn't close at the same level of the freezer door. I started to adjust the hinges and noticed a chewed up black 'washer' at the base of the door hinge. Ppartselect.com was awesome, in that I easily found the schematic of my fridge, and the part I needed. Ordering was a snap, and it came to the house pretty quickly.
Installation, first raise the door up as high as you can, then scotch it with wood blocks (closed door). This takes the pressure off the bottom hinge you must remove.
Taking the hinge off is a snap, but then the problem presented itself. The old door closing cam was riveted to the hinge. I couldn’t get the old one off! I ended up taking it to the garage and breaking out the Dremmel tool with the abrasive cutter (the one that will cut through nails. I ended up cutting off the rivet. This was a pain.
I then found a small nut/bolt and put the new piece on, then put it back into place and removed the blocks. Works good as new. The toughest part by far was getting the old cam off… but there may be some easier way to get the rivet out that I’m not aware of.
Good luck.
Installation, first raise the door up as high as you can, then scotch it with wood blocks (closed door). This takes the pressure off the bottom hinge you must remove.
Taking the hinge off is a snap, but then the problem presented itself. The old door closing cam was riveted to the hinge. I couldn’t get the old one off! I ended up taking it to the garage and breaking out the Dremmel tool with the abrasive cutter (the one that will cut through nails. I ended up cutting off the rivet. This was a pain.
I then found a small nut/bolt and put the new piece on, then put it back into place and removed the blocks. Works good as new. The toughest part by far was getting the old cam off… but there may be some easier way to get the rivet out that I’m not aware of.
Good luck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- J Barry from Sparta, NJ
- Parts Used:
- WR2X4901
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Socket set
The door closing cam had broken up.
The old cam had broken and was on the floor. I ordered one new cam. I should have been told to order at least two, I did not know they worked in pairs. So I had to re-order, I ordersed four, I was able to see that the other (freezer door has cracked cams) door will soon need replacement of the cams. I had trouble installing the new part because the rivit also needed to ba replaced. I did a "Rube Goldgerg" to get the new part to sit properly. I drilled the hole open a little and forced the part into place. All is well. Thank you very much!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from SUGAR LAND, TX
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light Switch Not Working - Needed New Switch
Remove the top cover above the door by lifting it slightly and pulling forward. I used a mirror to make sure that there was nothing in the way of accessing the switch from above. I used a blade screwdriver to press against the switch retainer on the topside, while GENTLY prying from below with another blade screwdriver to get the switch dislodged. Once the retainer was past the opening, I wiggled the switch downward and then rotated it to the left when the rounded top right edge of the switch was visible. This allowed the wiring to the connector to pass thru the hole. I pushed the wiring from the top and pulled from below to get the connector below the opening for the switch. I then unplugged the switch, plugged in the new switch and reversed the removal process feeding the connector thru first then rotating the switch to the right to get the rounded edge of the switch thru the opening, then pressed the switch up into the opening until it snapped into place. Total time less than 10 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gary from EAST JORDAN, MI
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Light went out in refrigerator
Pop out switch, pull wires, attach wires to new switch and pop back in. Easy smeasy!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Salinas, CA
- Parts Used:
- WR2X4901
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Socket set
Door closing cam split in two and door would not automatically close anymore.
This one is a no brainer… One Phillips screw on top to pull top door hinge trim. Two nuts and the top hinge is free. Then pull the door… it helps if you unload all the crap in the door bins. Remove the remnants of the door cam and that leaves a pop rivet. Put some vise grips on the head and use a hacksaw to remove the lower part of the rivet. Then pop-rivet the new door cam in place. If you don’t own a pop-rivet tool, I guess you could use a 10/32” screw and nylock. Plop the door back on and you’re done. Took all of about 15 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Lauraine from Rocky Hill, CT
- Parts Used:
- WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
family member melted fan with hair dryer
Unplugged fridge.Removed 2 screws holding a panel. After panel removed took off old fan and inserted new. Quite simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Glendale Heights, IL
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Light would stay on when door closed
Extremely easy repair, the hardest part was getting the old switch out. I used a pair of needle nose pliers to squeeze the tabs in and it came right out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Loren from EL PASO, TX
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
40 year old refrigerator brittle light switch fell apart
with a jewelry screwdriver I pried the lock tab in and pulled switch down carefully, the hardest part was that the power wire connector was stuck on good but the pliers and the jewelry screwdriver was its match for a bout 5 minute for one connection a simple pull off prong connection. After the wire connected back to switch it popped back in SNAPP
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sumlorq from Cleveland, OH
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light switch freezer door
put the gratefruit knife behind the old switch pooped it out pluged the new one in piece of cake 5min.even vacumed the dust off the coil
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Deborah from BRADLEYVILLE, MO
- Parts Used:
- WR23X37285
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Broken light switch
This was so easy I think it took me 2 minutes. I am not very mechanically inclined but that didn't matter! Works perfect thank you!
Was this instruction helpful to you?
Thank you for voting!