danny from west potsmouth, OH
Parts Used:
WR17X11653, WR17X23191, WR17X10706, WR02X10585
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Ice auger was broke and ice was freezing in the recess door
all parts worked and were easy to install. probably saved me from having to buy a new fridge. ice maker is working fine and recess door flap is closing correctly. very satisfied.
21 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeffrey from Williamsburg, VA
Parts Used:
WR17X22070
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
No longer needed water filters
Your website was very easy to use and the product shipped very promptly. It was great experience. Thanks!
22 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from Alamosa, CO
Parts Used:
WR60X10220
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Condenser Fan Motor stopped turning
1. Unplugged the fridge. 2. unplugged the fan connection and removed the wire holding clip. 3. removed the 2 screws holding the motor bracket in place and removed the bracket. 4. Pulled gently back on the motor so that the fan pressed against the front bracket until the fan slid off the motor shaft. 5. Pulled the rubber motor mounts off of the old motor and placed on the new motor. 6. Slide the new motor in place pressed the fan all the way onto the shaft. 7. Placed the rear motor bracket in place and started the screws by hand making sure the ground wire was attached to the furthest away screw. 8. tightened the screws down. 9. Pushed in the wire holding clip into the clip hole. 10. Plugged back in the fan. 11. Plugged back in the fridge. 12. Turned down the temp on the fridge to kick on the compressor and checked to assure the fan was operating and then set the temp back to normal. 13. Vacuumed the condenser coils to get them all clean and ready for more years of service!
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
calvin from annapolis, MD
Parts Used:
WR62X10055, WR17X11653, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
when dispensing ice the flap door would not open properly and was open most of the time causing the door to ice up...cause solenoid was rusted badly
I removed the screws for the inner door and removed inner lining. Then took out the ice dispenser in the door. Took off control panel on the front of the ice panel. Removed the rusted parts and put in new parts. Put all parts back the way it came apart. In retrospect.... I could have possibly replaced the parts from the front panel but by taking apart the door...I had to thaw out the inner panel and insulation with in the door.
19 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason` from Colchester, CT
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Hanford, CA
Parts Used:
WR01X10315
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Ice Maker auger blade broken
The ice machine auger blade broke a chunk off. I decided to try to replace it myself. I bought the new auger blade and then sat there and stared at it and the ice machine for a few, trying to figure out how to change out the part. Turns out it was a qute lengthy process. The auger is threaded on one end and the ice chopping blades are on it. So I had to take each blade off the old one and put it on the new one. The blades have to be positioned just right on the shaft so it's best to just draw a line down over all the blades so as to put them on the new auger successfully. The problem I had was the end cap that screwed on the end of the shaft. It was the part I ordered here. It is made of plastic with plastic threads and at first I couldn't figure out to get it off. Turns out the threads are opposite normal. By the time I figured that out, I had just about destroyed the cap using pliers to try to unscrew it. There is a washer and half moon clip that fastens on this end nut so if you mess the nut up, chances are you won't be able to get the half moon clip to go back on. I finally did it right and now how the ice maker working right again. A hard part for me was figuring out how to set the spring shaft that works a lever to either give cubed ice or crushed. I had to keep fiddle with it before I finally got that right. At first I was only getting crushed ice even with the cubed setting and then only getting cubed ice with the crushed ice setting. After some fiddling, I got both to work but to this day can't figure out what changes from the crushed setting to the cubed setting.
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cristina from Los Angeles, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Republican City, NE
Parts Used:
WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker door failed to close letting ice melt
Removed the front panel on the door that has the ice maker controls. Removed the screws and parts. Reassembled the parts and it works better than new. Ice door closes firmly and holds tight.
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sheila from Robeline, LA
Parts Used:
WR02X11941, WR62X23154
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
ice auger drive stripped out, solenoid burned out
removed ice tray, removed drive unit. removed solenoid and replaced, screwed on auger drive. reinstalled drive assembly. replaced ice tray. job done.
21 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Billings, MT
Parts Used:
WR17X11267, WR17X11170, WR17X10745
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Melted Dispenser Housing Shield with hair dryer trying to thaw out frozen water line
Pull plastic trim piece off refridgerator door,unclip printed circuit board and remove wires unscrew dispenser housing,and remove. Transfer Ice funnel to new dispenser housing with old spring. Reinstall dispenser housing and printed circuit board.
25 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
debbie from chino hills, CA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
icemaker developed a leak and froze over
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
18 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Spring, TX
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
"Moaning Myrtle" syndrome. Refrigerator makes a whooing sound for hours at a time
Checked the internet for reports of similar problems and concluded that it was probably the main control board. Not being particularly handy, I would never have attempted to change the board myself if I had not read the comments and instructions from people on this site. Thanks.

The job was as straight forward as others have described. The only time I had a problem was pushing in the white tab to be able to pull the old board out. That was a bit of a fiddle.

The only thing I found different was the grounding wire. On the original board, this wire was at the bottom of the board and hooked into a wire that ran into the refrigerator. On the new board, the wire was at the top of the board and had a metal loop on it. If I understand it correctly, with the new grounding system the wire is pushed into the space above the board. Then when the back plate is reattached the metal loop makes contact with it , thus grounding the refrigerator.
I chose to run the grounding wire through the original wire into the refrigerator. That meant cutting off the metal loop, slicing in an extra piece of wire to connect the grounding wire on the board to the grounding wire into the refrigerator.

I also now use a surge suppressor for the refrigerator. The “Moaning Myrtle” syndrome started after Hurricane Ike. I suspect the surge when the power was restored damaged the control board. And as so many people seem to have this “Moaning Myrtle” problem, I suspect the control board has little or no surge protection.
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from muskegon, MI
Parts Used:
WR01X10650, WR13X10286, WR13X10285, WR02X11482, WR01X10379
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
missing top hinges
all the right parts came lightning fast. piece of cake.
16 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Milford, UT
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
fridge wouldn't cool, frozen food thawed
First my wife and i took the panel off the back, unscrewed the old mainboard, unplugged all the switches from it and prayed that the new one would work. We were without a fridge for 2 weeks beginning 2 days before Christmas!!!!! Gingerly, we put the new board in place, screwed it into the fridge, connected the switches, attached the ground wire, and held our breath as we plugged it back in. Within seconds, the familiar sound of water filling the icemaker was hear and there were cheers all around!!!
15 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Simi Valley, CA
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
19 of 33 people found this instruction helpful.