Leaking Water
Unplugged frig. Turned off water supply to pump. Removed black cardboard covering on back of frig with nut driver (6 screws).
Took digital photo of assembly to confirm reassembly position.
Removed copper waterline to pump with adjustable wrench. Removed 1 screw holding pump assembly to refrigerator. Pulled assembly out of the frig. Unscrewed two small black screws on a second bracket. Pulled old pump further out of frig. Unplugged two connectors. Removed plastic waterline from pump by turning hose counter-clockwise and gently pulling.
Inserted plastic water line into new pump by turning line in clockwise and it pushing into orange plastic stop. Reconnected two electrical connectors. Reconnected bracket to pump with two small black screws. Gently pushed assembly back into the frig and reconnected pump assembly to the frig with 1 screw. Reconnected copper water line to pump first wrapping threads on pump with Teflon plumbers tape.
Turned on water to check for leaks. Installed cardboard back on frig with 6 screws. Plugged in frig.
NOTE. My new pump assembly had the electrical connectors reversed. Take care to pair up the correct colored connectors.
Took digital photo of assembly to confirm reassembly position.
Removed copper waterline to pump with adjustable wrench. Removed 1 screw holding pump assembly to refrigerator. Pulled assembly out of the frig. Unscrewed two small black screws on a second bracket. Pulled old pump further out of frig. Unplugged two connectors. Removed plastic waterline from pump by turning hose counter-clockwise and gently pulling.
Inserted plastic water line into new pump by turning line in clockwise and it pushing into orange plastic stop. Reconnected two electrical connectors. Reconnected bracket to pump with two small black screws. Gently pushed assembly back into the frig and reconnected pump assembly to the frig with 1 screw. Reconnected copper water line to pump first wrapping threads on pump with Teflon plumbers tape.
Turned on water to check for leaks. Installed cardboard back on frig with 6 screws. Plugged in frig.
NOTE. My new pump assembly had the electrical connectors reversed. Take care to pair up the correct colored connectors.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Steven from Cave Creek, AZ
- Parts Used:
- WR30X10093
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Victor from Houston, TX
- Parts Used:
- WR62X10055, WR17X11653, WR17X10706, WR02X10585
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The compartment behind control panel with snow
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.
I recomend these parts be replaced once time for each two years.
I recomend these parts be replaced once time for each two years.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from El Paso, TX
- Parts Used:
- WR57X10026
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
water dispenser in door failed to dispense water
Unplugged refrigerator from electrical outlet for safety and turned off water supply valve. Removed the four metal screws that hold the access cover on the rear of the refrigerator. Then removed single metal screw attaching water valve and bracket assembly. Unplugged wire harness from the water valve and assembly then pressed down on colored o-rings to detach the four plastic water lines from the water valves. Used open end wrench to disconnect main water supply line from the water valve.
Pressed down on colored O-rings to install the four plastic water lines to new water valve and bracket assembly. Wrapped plumbing tape on threads of inlet valve and and used open end wrench to attach main water supply line to new water valve and bracket assembly. Attached wiring harness to new water valve and bracket assembly. Mounted new assembly to refrigerator with single metal screw. Turned on water supply valve and checked for leaks. Plugged in refrigerator to electrical outlet and tested water dispenser. Replaced access cover on rear of refrigerator with four mounting screws.
Pressed down on colored O-rings to install the four plastic water lines to new water valve and bracket assembly. Wrapped plumbing tape on threads of inlet valve and and used open end wrench to attach main water supply line to new water valve and bracket assembly. Attached wiring harness to new water valve and bracket assembly. Mounted new assembly to refrigerator with single metal screw. Turned on water supply valve and checked for leaks. Plugged in refrigerator to electrical outlet and tested water dispenser. Replaced access cover on rear of refrigerator with four mounting screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- joe from raleigh, NC
- Parts Used:
- WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
ice despenser door would stick open and frost up to the point of of ice not coming out
after finding the video describing the same problem, i gave it a shot. Major problem was figuring out how to take outside trim off of the ice/water dispenser. Everything i tried did not work like the videos i had seen. Looking thru some of the posted blogs i found another way to get behind the control panel without even taking off the trim piece. i pressed a 1/8th allen wrench into the two outer holes on the bottom of the control panel which released the panel to pull out from the bottom. after that it was simple to release the three plugs from the circuit board and remove the control panel. 4 phi lips screws later the ice chute comes straight out revealing the flapper door which is held in by 2 more screws. once that assembly is out the solenoid is held by three more screws. there was nothing difficult at all about this repair once the secret was out about the first step about the three holes (use only the outer two) in the bottom of the control panel
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- john from waxahachie, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
No water or ice and a constant ticking sound from the control panel
Very easy repair to do. Read instruction sheet before starting! Unplug unit prior to removing panel cover.
Remove three hex head screws holding control panel cover in place and reveal the circuit board.
Remove all the wiring harnesses by gently pulling them from the sockets on the board. Do not pull the wires - make sure you pull on the plastic socket so that the wires aren't damaged. If plugs seem tight use needle nose pliers to gently wiggle them out. Remove earth (green) wire from spade connection on fridge chassis. The new board has a slightly different connection for the earth wire.(No spade connector - wire now has a ring connector that attaches between panel cover and fridge chassis using one of the hex head panel screws when the cover is replaced.
Using needle nose pliers locate four plastic mounting tabs holding the board in place and squeeze in the end of each tab whilst gently pulling the board off it. Repeat for all four tabs and remove old circuit board.
Making sure the new board is the right way round locate it on the plastic tabs and push gently until you hear the tabs click. Gently pull the circuit board to ensure it is locked in place.
Re-install all the wiring harnesses. Put a hex head screw through the cover panel and slip the earth wire ring over it and screw panel to chassis. Replace two remaining hex head screws and plug fridge back in.
Voila!! No more ticking sounds and a plentiful supply of ice and water!!
Remove three hex head screws holding control panel cover in place and reveal the circuit board.
Remove all the wiring harnesses by gently pulling them from the sockets on the board. Do not pull the wires - make sure you pull on the plastic socket so that the wires aren't damaged. If plugs seem tight use needle nose pliers to gently wiggle them out. Remove earth (green) wire from spade connection on fridge chassis. The new board has a slightly different connection for the earth wire.(No spade connector - wire now has a ring connector that attaches between panel cover and fridge chassis using one of the hex head panel screws when the cover is replaced.
Using needle nose pliers locate four plastic mounting tabs holding the board in place and squeeze in the end of each tab whilst gently pulling the board off it. Repeat for all four tabs and remove old circuit board.
Making sure the new board is the right way round locate it on the plastic tabs and push gently until you hear the tabs click. Gently pull the circuit board to ensure it is locked in place.
Re-install all the wiring harnesses. Put a hex head screw through the cover panel and slip the earth wire ring over it and screw panel to chassis. Replace two remaining hex head screws and plug fridge back in.
Voila!! No more ticking sounds and a plentiful supply of ice and water!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Lodi, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Suffolk, VA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Mason, OH
- Parts Used:
- WR23X10783
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Water dispensor would not shut off
Actually this was a two part repair of which I purchased both parts. The micro switch Pt # PS296176 and also a double outlet water valve Pt # PS304374 from Parts Select as well.
The difficult part was accessing the area to get to the micro switch.
The trim had to be removed, then the cover.
Then one unplugs the board and removed the face plate which also contains the micro switch.
Once removed the two electrical terminals had to be disconnected, the micro switch installed and terminal reconnected.
Then reverse the removal procedure.
Then on to the double outlet replacement.
Suggest watching the installation video for the replacement although it was really a straight forward repair.
Two things to remember.
1. Unplug the fridge
2. Shut off the water to the dispenser
Overall it was not bad at all.
This was my first attempt at refrigerator repair and it went well.
Good luck on yours.
John
The difficult part was accessing the area to get to the micro switch.
The trim had to be removed, then the cover.
Then one unplugs the board and removed the face plate which also contains the micro switch.
Once removed the two electrical terminals had to be disconnected, the micro switch installed and terminal reconnected.
Then reverse the removal procedure.
Then on to the double outlet replacement.
Suggest watching the installation video for the replacement although it was really a straight forward repair.
Two things to remember.
1. Unplug the fridge
2. Shut off the water to the dispenser
Overall it was not bad at all.
This was my first attempt at refrigerator repair and it went well.
Good luck on yours.
John
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ram from Atlanta, GA
- Parts Used:
- WR57X10023
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Water had leaked out behind the refrigerator and seeped into the basement walls. Noticed the paint peeling off the walls and traced the problem to the refrigerator's leaky valve
The leak was obvious and I took out the cardboard backing. I closed the valve (water supply) to the water dispenser and ice maker.
With the screw drivers and socket set, I was able to take out the old valve and disconnect the hoses.
Since the part was identical to the leaky valve it was just a matter of reversing the steps. I had previously researched on the web to find the identical part and found a match at Partselect.com. I wish all my repair attempts turn out to be this easy. I wish GE had used better parts since this incident has set me back by several thousand dollars due to the water damage to the wooden floors, basement ceiling and walls.
With the screw drivers and socket set, I was able to take out the old valve and disconnect the hoses.
Since the part was identical to the leaky valve it was just a matter of reversing the steps. I had previously researched on the web to find the identical part and found a match at Partselect.com. I wish all my repair attempts turn out to be this easy. I wish GE had used better parts since this incident has set me back by several thousand dollars due to the water damage to the wooden floors, basement ceiling and walls.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Daniel from MIAMI, FL
- Parts Used:
- WR60X10205, WR60X10185, WR02X12149, WR02X12008, WR02X10540
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
loud whinning noise of fan in freezer section
1. content of freezer was put in an ice box
2. panel covering rear of freezer compartment was removed, a few screws
3. old fan now accessible was removed an new fan mounted.
4. modular wiring plug broke, wires had to be soldered and wrapped in heat shrunk insulation
5. compartment was cleaned an rear inside panel closed
Thanks for all those who shared their experience and the schematics available on website. It gave me the confidence to to this myself. Its my second repair in freezer (previous being a defective heater)
2. panel covering rear of freezer compartment was removed, a few screws
3. old fan now accessible was removed an new fan mounted.
4. modular wiring plug broke, wires had to be soldered and wrapped in heat shrunk insulation
5. compartment was cleaned an rear inside panel closed
Thanks for all those who shared their experience and the schematics available on website. It gave me the confidence to to this myself. Its my second repair in freezer (previous being a defective heater)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Otsego, MN
- Parts Used:
- WR62X10055, WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
water & Ice disspenser quite working
first replace the solenoid behind the front display. than replace the mother board on the back side of the fridge due to a relay being burned out on it.
GE Wanted $300 + to come out and do the repair.
With partsselect and a little time I cut that cost in half.
Thank you,
Mike
GE Wanted $300 + to come out and do the repair.
With partsselect and a little time I cut that cost in half.
Thank you,
Mike
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeremy from Anniston, AL
- Parts Used:
- WR57X10023
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers, Socket set
top of the valve ruptured
Isolated water line. Remove water valve from harness. Disconnect water connections. Disconnect electrical connections. Removed valve. Installed new part. Reconnected water connections and electrical connections. Opened water line.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Tacoma, WA
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
water running slow
unscrewed old filter by hand, installed new filter.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William M from Ft Myers, FL
- Parts Used:
- WR62X10055, WR01X37886
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Solenoid had become rusted/crank door wouldn't close
First, had to use punch tool to pop out electronic face panel. Face unit still connnect via wires. Use painters tape to hold against refrig. Next, Remove ice/water dispenser and also tape to door. This will give you access to solenoid. Remove the 3 screws holding it in place and unplug fsolenoid from Face Panel. Screw new solenoid and place and connnect to Panel. Goood idea is to unplug regrig. while doing this and put a little WD-30 on shaft of solenoid. May want to order new screws, could be rusty, that hold solenoid in place. Sounds a bit complicated but not that bad a job. You'll save over$100 over GE's service.
Was this instruction helpful to you?
Thank you for voting!