glenn from la harpe, KS
Parts Used:
WR60X203
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
drain freezing up found cond fan not working
Cleaned oh t freezer removed floor. Removed back inside wall removed and replaced fan and put back removed parts


L
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from VERO BEACH, FL
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
The Refridgerator and Freezer were not cooling.
Installing the part repaired the fridge and freezer immediately.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from PRESQUE ISLE, ME
Parts Used:
WR2X9296
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
broken shelf end caps- right side of 2 shelves.
After watching video I took off end shelf caps. It took close to 10 mins to replace them.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
paul from ENDICOTT, NY
Parts Used:
WR55X24064
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
freezer stoped freezing
my freezer quit freezing, it would freeze for one day, thaw the next, so I went online, found PARTS SELECT, LOOKED UP MY MODEL #, come to find out it needed three parts to keep my freezer to freeze, first part was a thermistor a small PART took me longer to remove all the covers, and shelving, PULLED THE OLD OUT, CUT THE WIERS TO SIZE, AND REINSTALLED, IT WELL! THAT WASN'T ENOUGH THE FREEZER STILL DIDN'T FREEZE IT THOUT IT WAS A COOL WORMING OVEN, HAD TO INSTALL THE THERMISTOR I, SO I DID, TEN MIN, NOW I THOUGHT THAT WAS IT BECAUSE IT STAYED FROZEN FOR A WEAK, HAVE YOU EVER EATEN SOUPY ICE CREAM? SO BACK TO PARTS SELECT, THIS TIME I BOUGHT ONE MORE PT, THE RUN CAPACITOR, FIVE MIN, THAT/S ALL IT TOOK TO INSTALL. I DID NOT KNOW AT THE TIME YOU NEED THE THREE OF THEM TO RUN THE FREEZER ONE TO KEEP THE TEMP., ONE TO KEEP THE FAN RUNNING THE WAY IT SHOULD, AND THE THIRD TO MAKE SURE THE OTHER TWO KEEP RUNNING. NOW I CAN SET IT AT 4- 5 AND. FREEZE.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joyce from Tacoma, WA
Parts Used:
WR2X9391
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light wouldn't come out of socket
It just unpluged and the new one plugged in. Simple. The part was reasonable and arrived very quickly. It sure is nice to have a light in the frig again.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
kenneth from carmel, NY
Parts Used:
WR60X123
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Not cooling and freezer freezing up
I removed the condenser cover removed old fan blade defrosted the condenser section installed new blade and reassembled
6 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rose from Cincinnati, OH
Parts Used:
WR2X7975
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
End caps on door retainer bar were broken and shelf could not be used.
I replaced the end caps on the retainer bar on the freezer door and also the ref. door in less that 5 minutes. Both are working fine now. I am a 75 year old women who is very happy with the repair.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
marj from NEWBURY PARK, CA
Parts Used:
WR2X9391
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fridge light dead even with new bulb
1- youtubed the potential diagnoses, 2- resourced and ordered parts, 3- removed old socket, installed new one :-)... My fridge is an older fridge and could've used a screwdriver for eyeglasses. Plug and play easy... YAY!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Rowe, VA
Parts Used:
WR2X9391
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
bulb out
I ordered the part, within two days we had received it. My husband put the part in and I really don't know what he used doing so. All I know is that the light works now and we don't have to use the flashlight. Thanks a lot.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Nan from PURCELLVILLE, VA
Parts Used:
WR2X9391
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
My light in the refrigerator was going on and off.
I unplugged the refrigerator. Pressed the tab near the light bulb. Unplugged the socket and reconnected it.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ED from ENON, OH
Parts Used:
WR2X9391
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Short in the light socket.
Un Plugged the frig. Unlocked the socket by pressing down on the latch. Pulled the socket out ensuring I had enough slack. Unplugged the old socket installed the new. Plugged the frig back in. Tested the switch . Very easy-to-use.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
QUOC-LOC from LYNN HAVEN, FL
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Erika from Joliet, IL
Parts Used:
WR2X9296
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Door shelf clip had broken
This shelf has been broken for about a year now and my husband tried several little quick fixes that would work for a while and then the shelf would fall again. A quick search online led me to your website, the part arrive within two days, and the shelf was fixed in less than ten minutes. It's working great. We'll definitely keep you in mind for the future.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Charlotte, NC
Parts Used:
WR2X9391
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
socket had melted
pluged the wire harness into the new socket from the back and snaped the socket in place.
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Miranda from Waterford, CT
Parts Used:
WR2X9296
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The end cap on the door shelf snapped off.
I pulled off the broken piece, ordered the new piece, and snapped it on. VERY SIMPLE.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!