GNR22DGEAFWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Rafael from New Haven, CT
- Parts Used:
- WR50X10068
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
ice on the frezer compartment
turn off the refrigerator,then open the cover and saw lot of ice. then get a hair dryer blower and blow a heat to melt the ice. cut the thermostat defrost.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from Bartlesville, OK
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mahvash from Gold Canyon, AZ
- Parts Used:
- WR50X10068
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Refridgerator warm, some ice buildup apparent in freezer
Find online diagram of freezer section for reference. Disconnect power, remove evap cover plate (214) by removing one of the drawer guide rails.
As evidence of your problem, you might see a giant block of ice built up around the coil. Let this defrost this before continuing.
Find THERMOSTAT DEFROST (24) sensor and clip connecting wires. Match replacement sensor wires by color. Twist and solder wires; or wire-nuts and twisting alone might be okay. If not soldering, seal the wire-nuts connections from moister with a good sizeable piece of duct tape. Make sure your wires are out of the way and not left dangling on the evap heater coil, where they could melt.
Suggest concurrent replacement of evap fan motor if this has not already been done in the past.. This become noisy with age and damage from the ice build up seems to have made mine worse.
As evidence of your problem, you might see a giant block of ice built up around the coil. Let this defrost this before continuing.
Find THERMOSTAT DEFROST (24) sensor and clip connecting wires. Match replacement sensor wires by color. Twist and solder wires; or wire-nuts and twisting alone might be okay. If not soldering, seal the wire-nuts connections from moister with a good sizeable piece of duct tape. Make sure your wires are out of the way and not left dangling on the evap heater coil, where they could melt.
Suggest concurrent replacement of evap fan motor if this has not already been done in the past.. This become noisy with age and damage from the ice build up seems to have made mine worse.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patrick from Punta Gorda, FL
- Parts Used:
- WR50X10068
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Rear of freezer all iced up would not defrost
first removed two srews removed rear panel hair dryer to melt ice (took 30 minutes) cut two wires to thermostat spliced onto new part clipped it onto tube -done replace rear panel and 2 screws. very easy job after reading other letters and their experience -saved myself $500.00
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- QUOC-LOC from LYNN HAVEN, FL
- Parts Used:
- WR55X24064
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Louis from LEAGUE CITY, TX
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Change bulb
Easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephanie from KEARNY, NJ
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light was flicking
It was way to ez to install only a couple of minutes that's it
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ED from ENON, OH
- Parts Used:
- WR2X9391
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Short in the light socket.
Un Plugged the frig. Unlocked the socket by pressing down on the latch. Pulled the socket out ensuring I had enough slack. Unplugged the old socket installed the new. Plugged the frig back in. Tested the switch . Very easy-to-use.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ted from SANDWICH, IL
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Broken light switch
took a little more effort than the video show to remove old module and replace new. Works fine now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chris from Charlotte, NC
- Parts Used:
- WR2X9391
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
socket had melted
pluged the wire harness into the new socket from the back and snaped the socket in place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from Eugene, OR
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The door activated light switch was missing.
Pulled the two wires out from the access hole in the lower part of the refrigerator. Put them in the spade connectors on the new switch, and pushed the switch into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roscoe G from ROCHESTER, NY
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Susan from Sea Cliff, NY
- Parts Used:
- WR50X10068
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The freezer temperature was increasing.
i took out back frame and cleared off the ice on the metal condenser. I cut wires from old thermostat and removed it. Stripped new wires and attached to the wires in the frig. We taped it with electrical tape and put it back and closed it up. it works beautifully! We watched a video on youtube and that helped a great deal!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- richard from cleburne, TX
- Parts Used:
- WR50X10068
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
warm, refrigerator/freezer,frozen up
verify the heating element was o.k., found the top of the thermostat popped off,it had water in it,probably froze and came apart,cut the wires to the old thermostat and splice the new ones together,put the cover back on and verify operation
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from Issaquah, WA
- Parts Used:
- WR2X9391
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Light socket missing in refrigerator
Frig parts had been scavenged in an apartment complex. Restoring socket was only a matter of plugging in two spade contacts and clipping in socket.
Was this instruction helpful to you?
Thank you for voting!