ZIRP360NHALH General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- ANTHONY from NEW EGYPT, NJ
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
sticky switch
easy pry out, disconnect wiring, connect on new switch and press in switch.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- christopher from collegeville, PA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
no light in freezer
Connected the 2 wires and pushed in the switch until it clicked.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cynthia from Seatac, WA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
switch wouldn't come out anymore and turn light on
Gently pry out switch in door jam with screwdriver and pull both connectors off and put connectors on new switch then push switch back into the hole. Looked it up on the internet and video showed how to and also had link to new part, ordered and less than a week later the fridge is bright again. I have an older freezer also and it seems that they all use the same switches. Very Very easy
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ronald from hilton Head Island, SC
- Parts Used:
- WR71X10140, WR71X10139, WR32X10119
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
cracked items
replaced with new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from New Smyrna Beach, FL
- Parts Used:
- WR60X10209
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Socket set, Wrench set
Condenser fan not working. Freezer & frig heating up
Very limited working space in this model. Must remove grill and disconnect elect connector on motor. One additiional tool suggested: Extendable rod with magnet on end because you will most likely drop something. First, remove two screws holding motor to metal strap. Tool must be inserted between blades of fan in order to get to the screws and this is the hard part. Fan and motor are removed as one assy and this takes some manuvering. Might have to remove front screw on metal strap to gain more room. I did not attempt to remove fan shroud. My fan was attached to the motor shaft with a metal clip. Spray a good lubricant such as PB Blaster on the shaft, wait a few minutes and press it or tap it out gently. Save misc parts on old motor for reassembly. Your set up may be different so check out everything before starting.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from Seattle, WA
- Parts Used:
- WR60X30922
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver
broken fan blade
about an hour to figure out what was causing the vibration and noise and about an hour to put it back together and 5 min. to order a new fan blade thank you.It started making noise during thanksgiving dinner so we toke it apart after dinner and I cut the other 2 blade to match the broken one so to cut down on the noise and vibration semi put it back together and 7 days later the part arrived.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Vincent from Lyndhurst, NJ
- Parts Used:
- WR02X12149, WR02X12008, WR02X10540
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Unusual noise from freezer.
Replaced above parts and the noise problem was not resolved. Ordered a new motor, fan blade and another set of grommets from PartSelect. The parts were delivered the next day. Took me about 15 minutes to swap the new parts in. It's been 3 days since the repair and the noise has not returned.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GLENN from PATTERSON, CA
- Parts Used:
- WR60X30922, WR02X12149, WR02X12008, WR02X10540, WR02X10322
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Making loud knocking noise
remove the Ice tray, remove hex bolts from ice tray hangers on side of freezer. unscrew ice maker and remove it. Remove ice tray auger motor assembaly (4 hex bolts) remove 2 more hex bolts from top of rear inside panel. remove 4 hex bolts from lower panel as well. now with lower section out, you should see the last 2 hex bolts holding on plastic shield (top section rear panel) un screw light cover. Squeeze light fixture and push in. now remove entire top section of panel. All will be exposed. Remove old motor housing, disconnect wires, remove clip from coils. (NEW MOTOR DOES NOT HAVE CLIP OR WIRE FOR COILS)Attatch new motor and replace grommits. Reverse instructions for re installation.
Was this instruction helpful to you?
Thank you for voting!