Models > PFRF2MBXAWW > Instructions

PFRF2MBXAWW General Electric Refrigerator - Instructions

Jump to:

All Instructions for the PFRF2MBXAWW
91 - 105 of 110
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
joe from decatur, GA
Parts Used:
WR55X24064
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
Freezer And Frig Both Warm And Compressor Would Not Run
I replaced the thermostat, temperature sensor, and the run capacitor. . . Refrigerator still not cooling. I checked the start relay and measured the input terminals on the compressor for the correct resistance. . . Everything measured correctly. In a last ditch effort before calling for service, I pulled the main board, inspected it and saw the problem right away. One leg on the compression capacitor had desoldered itself. Got out my soldering iron and applied a good amount of solder to that point. Put everything back together and turn it on. . . Problem fixed. The compressor kicked on right away and started cooling the refrigerator.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ajaykumar from Plainsboro, NJ
Parts Used:
WR60X10209
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
The refrigerator was making load and unusual noises.
I identified the noise was coming from the coils / and the fan. Cleaning the fan helped reduce the noise a bit but it still kept recurring. I ordered the part, which was really easy using the diagram on the website. The instructions and the video were really helpful and was able to remove the old motor and replace it with the new one with relative ease. While there I cleaned the fan blade and vacuumed the surrounding area. This whole repair went quite smoothly and has given me the confidence to take on other repairs before calling out the repairman.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PFRF2MBXAWW