DSRF3KGXACWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Robert from Mahopac, NY
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice maker solenoid failure
several times I had to remove the ice maker door solenoid due to it sticking. I ordered a new one from parts select. Problem solved!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bob J from Platte City, MO
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Water not dispensing
Background: My refrigerator was part of the class action law suit back in 2006. As a result both doors, the auger in the ice maker and a heating element in the freezer were all replaced.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- M Alan from Lebanon, TN
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker door didn't open and close properly
I removed the outer plate by sticking a very small screwdriver in the small holes at the bottom of the plate and pulling the plate toward me.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from White Pine, TN
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Would not cool top or bottom
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anthony from Miramar Beach, FL
- Parts Used:
- WR62X10055, WR01X37886
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Frost In Frezer Compartment Where Chute Meets Ice Cube Maker
Removed front panel (using small screw driver) by popping it out, disconnected wire from solenoid, removed solenoid which was rusted, 3 small philip head screws held it in place insereted new solenoid,connected wire snapped front panel back in. Clapper valve closes tightly and no frost in frezzer, saved my self a bunch of money.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Keller, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Johnnie from KANSAS CITY, MO
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
The Ground wires wasn't in same location on board
i had to improvise And relocate ground wire to get a proper ground .. That's all , the video was a GREAT HELP...
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clyde from RIALTO, CA
- Parts Used:
- WR60X24484, WR60X10209
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from GAINESVILLE, VA
- Parts Used:
- WR02X45206
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Socket set
Water dispenser making a pulsing noise
Watched YouTube video
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dean from Folsom, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Maricela from SAN ANTONIO, TX
- Parts Used:
- WR71X10973, WR71X10761
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Broke the clear plastic shelf cover
It just snapped in place
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alex from Tampa, FL
- Parts Used:
- WR57X33326
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Wrench (Adjustable)
Water not dispensing
Moved refrigerator forward, this allowed me to work on the back panel. Unplugged the refrigerator power cord. Released all 6 screws, removed panel then release an additional screw that was holding the water valve and the two (red & blue) connectors. Then installed the new part in reverse steps. Plug the unit and job well done. I had purchase the water filter already after several minutes push for water from the dispensing front part of the refrigerator and good to go, later in the evening we notice the ice maker working fine and producing ice. Thank you parts select.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Lincoln, CA
- Parts Used:
- WR01X37886
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
light burned out
unscrewed lamp and replaced it with new one!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bert from SAN JOSE, CA
- Parts Used:
- WR60X30922
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
INTERMITENT LOUD NOISE FROM EVAPORATOR FAN IN FREEZER
The repair did not go exactly the way it was described in the YouTube video, but basically it was similar. After unplugging the power cord, emptying the freezer, removing the shelves and the ice reservoir, I removed the ice maker assembly by unscrewing a Philips head screw and unplugging the power connector. The connector had little retaining tabs on each side that I pried open with a straight blade screwdriver. Then the ice maker lifted right out. Next I removed one screw holding the auger motor assembly, unplugged the power connector, and lifted out the assembly. This where things got difficult. After flailing around a bit, I removed the panel on the back wall of the freezer below the evaporator fan assembly, exposing the evaporator coil. I saw that the fan assembly was attached with two screws at the top and two screws at the bottom. The top screws were easily removed, but when I removed the bottom screws, which were situated in very tight quarters, I DROPPED BOTH SCREWS DOWN BEHIND THE EVAPORATOR COIL. Be prepared with a magnetic nutdriver so this doesn't happen to you. I could not retrieve the lost screws, but fortunately it appears that the top screws hold the assembly securely enough. The assembly was loose, but it was still attached by a power cord that I could not disconnect. I removed the tracks on the side walls for the ice bucket, and then I could maneuver the fan motor assembly just enough that I could reach over the top of it, grab and pull off the old fan blade, and slide the new fan blade onto the shaft. Reassembly was straightforward, replacing each part (except two lost screws) in reverse order to disassembly. After getting everything put back in and plugging in the power cord, I was amazed at how quiet it ran.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Clarksville, GA
- Parts Used:
- WR55X10942C, WR55X24064
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Electric surge from lightening strike close to house
Obvious that main electronic board was fried. Refrigerator and freezer both not working although fan was running. Replaced main board and run capacitor. Compressor not running. Pulled starter relay and checked compressor connections for continuity. Checked ok. Ordered starter relay and installed with new capacitor. Compressor started and has been running quiet and cold ever since. Thanks to videos on partsselect website for offering the confidence to try the fix myself. Total spent on parts and shipping,$350. I had electric provider install surge protection behind meter for a cost of $5.70 a month. Hope it works as advertised.
Was this instruction helpful to you?
Thank you for voting!