Models > 32120 > Instructions

32120 General Electric Refrigerator - Instructions

Jump to:

All Instructions for the 32120
31 - 37 of 37
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
JOSE from NEW YORK, NY
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
fan and compressor wont start
Googled the model number of refrigerator with symptoms of "refrigerator wont run". Parts select web site appeared on my screen, opened Parts Select website, Partselect said probable cause of my frige symptom was that the run capacitor usually burns out 51% of the time. They were correct with the diagnosis 100%. I ordered the run capacitor for $23.00, installed it in 10 minutes, refrigerator runs good as new. Thank you for saving me cost of service call. I probably saved $200 or more. I will use Partselect again with my next problem. THANK YOU,
Was this instruction helpful to you?
Thank you for voting!
Customer:
joe from decatur, GA
Parts Used:
WR55X24064
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
Freezer And Frig Both Warm And Compressor Would Not Run
I replaced the thermostat, temperature sensor, and the run capacitor. . . Refrigerator still not cooling. I checked the start relay and measured the input terminals on the compressor for the correct resistance. . . Everything measured correctly. In a last ditch effort before calling for service, I pulled the main board, inspected it and saw the problem right away. One leg on the compression capacitor had desoldered itself. Got out my soldering iron and applied a good amount of solder to that point. Put everything back together and turn it on. . . Problem fixed. The compressor kicked on right away and started cooling the refrigerator.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Leavenworth, KS
Parts Used:
WR2X9391
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
light would not stay on
First I flipped breaker to off position for refigerator, Pulled down on socket and broke it free. Then took needle nose piars to pull wire and plug out from hole, so I could conect to new light socket then snaped it in place . Hardest part was getting wire and plug out of hole.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Williamsburg, VA
Parts Used:
WR2X9391
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
needed new light socket
Pulled out old socket.pushed in new one.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary from Farmingdale, NY
Parts Used:
WR55X24064
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Both the fridge aqnd freezer would not get cold.
Easy. Followed the video instrucations. the part was right there next to the compressor.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Rowe, VA
Parts Used:
WR2X9391
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
bulb out
I ordered the part, within two days we had received it. My husband put the part in and I really don't know what he used doing so. All I know is that the light works now and we don't have to use the flashlight. Thanks a lot.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Bel Air, MD
Parts Used:
WR55X24064
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Refrigerator and freezer drawer would not maintain set temperature
Condenser fan motor was running slow. This was not a problem included in your list of possible problems. I thought that maybe the capacitor was bad but have no way to check it. So I ordered one. when I received it, I installed it. That was not the problem. So I ordered a fan motor and installed it. That was not the problem. So finally I ordered a control board and installed it. That solved the problem. So maybe you should put "cond.fan motor runs slow" in your list of possible faults and what causes that problem. Capacitor was easy to install, simply remove the cover plate, flip off retaining wire, unplug the capacitor and replace. Fan motor was a bit more difficult. It must be removed from mount after fan scroll is removed. Remove one screw that holds scroll, bend the top down and remove. Then pull hard on fan blade to remove it. It must be installed on new motor. Two screws in frame mount can be removed with some effort if you have a 1/4" drive ratchet with a Phillips screwdriver bit. Then pull frame open and install new motor. Push fan blade on new motor shaft hard. Replacing control board was easy. I used a pair of long nose pliers with 90 degree bend to get mounting pins closed to pull board off.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 32120