Customer:
Steven from Helotes, TX
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers
Ice build up behind ice maker ,water chute frozen up
Unplugged ref.,turnned water off at wall and drained, removed back cover on lower part of ref. then removed screw holding water valve,unplugged both wires from unit,pulled the 3 water lines off,1 I had to cut, would not release,got new water valve,push 3 water lines in place,attached the 2 wires in place and screwed unit back on ref.and replaced back cover on ref. Then I got a hair dryer and thawed all ice that had built up behind and under ice maker in freezer,cleaned that mess up,turned water back on plugged in ref. All good ,repaired problem,old water valve was bad.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Centennial, AL
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light switch broke when I dropped a jar of jam on it.
The three bulbs would then remain on, so I loosened them to keep them off. I didn't know that the cooling system also would stop when the door was open, so for two days only the side freezer was operational. When I discovered that, I hot glued the switch button off, while I searched for a replacement part. The replacement part was an exact duplicate. A simple prying out of the old switch - using a screwdriver, and the reconnection of the two wires connectors to the new part, and clicking back in place ... done. Seriously, it took two minutes.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Linda from Tiverton, RI
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Freezer/Fridge not cold & compresser would not turn on.
For troubleshooting, I took off rear panel inside of the freezer compartment & determined that icing of the coils was not the problem & it did not apprear to be a defroster malfunction. All components appeared to be working properly except the compressor would not turn on and only room temperature air was being circulated by the fan. After narrowing the probable causes down to a faulty Main control board by reading as many similar posts as possible,I ordered the new control board. When it arrived the following morning via UPS(less than 24 hours!), I unplugged the wiring connections attached to the old board, (which was somewhat different in appearance), and then gently popped the circuit board off of the plastic retainer studs by pushing in the little retaining clip part of the studs in with a small screwdriver so the board could be released easier as I pulled outward. I popped the new board on the studs by gently & evenly pushing with a larger hut driver over the studs until it was locked in, being careful not to damage or over stress/bend the board. I placed the wiring connecters onto the pins on the board.....every connecter had a different amount of pins so improper connection was not possible. I placed the ground wire connection of the new board between the metal cover plate @ an adjacent screw location to ensure grounding to the back of the fridge sheet metal. I plugged in the refrigerator and was quite relieved when I heard the compressor start up after a second or two! Within moments the temp began to fall until it reached the proper temp in both compartments. Success!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fillmore from Asheville, NC
Parts Used:
WR17X11440
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
water was squirting out a crack in water tank assembly.
This was a great opportunity to clean the bottom 3 shelves. I unplugged the frig.,disconnected both water lines, unscrewed water tank, pulled water lines out, put new tank in and pushed new water lines in and connected them, and plugged frig. back in. I grabbed my glass to get a drink and feeling proud but no water. I thought about this for a while and came to the conclusion that the freezer was set to 9 and the water had frozen in the value in the door. I dropped the temp. in the freezer from 9 to 3 and after about 2 days the water worked just fine. I emptied the ice because it was clumped into one big piece. I heard the ice maker going to town all day long. I called for ice later and the motor that dispenses the ice was humming and no ice was dropping. I thought about it and could not come up with the answer so I called tech. at GE and he was no help. So I solved one problem and now I have another that I don't have an answer to. My last attempt is to remove the motor housing to see if gears are jammed or something else.
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carol from DAVIS, CA
Parts Used:
WR24X10155
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The refrigerator wouldn't stay closed because the gasket was worn
Looked it up on You Tube and basically followed the very simple instructions. Two minor differences: 1) I took the old gasket off while the door was still attached to the fridge. And 2) because it was a side-by-side freezer/ fresh food, I didn't have to take off the freezer door at all and the fresh food door was only attached at the top with 2 screws covered by a hinge cap. So I undid the screws and lifted it off the lower pin. We put the door on a table handle down and slightly off the table edge. Inserting the v-shaped rubber part of the gasket into the groove was easy- pinching it together with my fingers with a little hammer tap at the corners. Reinstalled the door and voila. 27 minutes!
Most of my DIY projects take twice as long as expected. Much time is spent taking off the old part then not as easy as expected to replace the new part. This was a breeze!
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Liberty, MO
Parts Used:
WR55X10942C, WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
My refrigerator/freezer had several problems; both frig and freezer wasn't cooler properly, some days everything froze. The ice maker stopped making ice and water was leaking in the freezer.
I first called a GE repairperson. The diagnose the problem and told me the main control board was shot and the double outlet water valve needed replaced. The estimate for both parts and repairs was $850.00. I thought the estimate was high so I did some research on-line and discovered I could purchase the parts myself. When I researched the part, a short video popped up explaining how to install the part. I watched both video's and did exactly what the guy in the video said and was able to repair my refrigerator/freezer myself. The total cost for both parts was $200.00, I save $650!!! Amazing. I ordered the part on Saturday, and was told it would take a week to 10 days to receive the part and the part showed up on my door steep the following Tuesday. I'll never call a repairmen first again. I'll research the issue through partselect.com and try to fix the problem myself. I am not technologically or mechanically sauvy and have spent thousands on repair bills in the past, no more will I do that.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Longwood, FL
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
No water dispensed from door tap, icemaker OK
The problem was both the valve and a frozen slug of water in the supply line located inside the door. After replacing the valve, I turned the freezer to a setting of 1 and in about 30 hours, water flowed out the tap.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tim from Mountain View, AR
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Ice cream melting, lettuce freezing
Removed the back cover over the control board, and made sure that the board was the same. It didn't look exactly the same, but figured that it was the same, just updated. Took out the board, moved the wires to the new board and reinstalled. Plugged it in and it came on, so I reinstalled the cover. Seems to be working to this day.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brian from WILLOUGHBY, OH
Parts Used:
WR1X2027, WR11X10009
Difficulty Level:
Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers
door won't seal
after replacing the door seal, I couldn't get the new seal to close and stay closed, so I replaced the closing arm and spring. The door will close now but not tightly and it's loosing cold air. So I made and patented a wooden block to put behind the freezer door handle and the refrigerator door handle to keep the doors closed. Available in black, white and natural tan. (just kidding about the patented part, but not the block)
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from HAYWARD, CA
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Water dispenser is not working........water not coming out!
Show installation!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
H E from St Simons Island, GA
Parts Used:
WR55X10942C
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator/Freezer Warm & Condenser Fan Not Running
The control board and access panel are on the back of the refrigerator, so you will need to roll/slide the refrigerator away from the wall to gain access to the panel. Be careful not kink the water line if you have an ice maker connection.
Unplug the power cord from power outlet on the wall.
On this model the control board is located behind a rectangular panel that is about 8" x 10". The panel is about 3 feet above the floor on the left side (as viewed looking at the back of the refrigerator).
Using a Phillips (cross point) screwdriver, remove the screws and the access panel cover. Look closely at the control circuit board and you will see 4 small white plastic protrusions sticking through the board -- these are the plastic posts that hold the board in place. There is a small tab that locks the board to the plastic mounting post. Use your needle nose pliers (or other small pliers) to compress the small tab on the post; and while squeezing, pull on the control board until it releases from the post/clip. Repeat this for each of the four posts and the board will now be free from the mounts.
Look at the plugs that connect the wires to the board and note the orientation of each plug. Each plug is a different size, so they will only fit into the socket of the correct size. On my refrigerator, there is one plug that is not connected to the board and is hanging loose, so don't get confused when connecting plugs to the new board - this one remains unconnected.
Firmly pull each plug from its socket on the board -- try not to pull by the wires. If you have a stubborn plug, grab it with your pliers and pull it out. There is a green ground wire connected by a screw into the refrigerator cabinet. Remove this screw and ground wire. (Note: on some models the green ground wire is fastened with a screw that holds the cover in place - just be sure to reconnect the wire when replacing the cover).
Insert all of the plugs into the new board -- be sure they are seated firmly. Reinstall the ground wire. Place the board over the plastic posts and push until the tab locks the board in place. Replace the cover.
On the sheet that comes with the refrigerator they instruct you to remove the lower panel on the refrigerator that covers the compressor motor compartment. They instruct you to look at the power cord connection to the compressor and to locate a green wire from a capacitor. If your power cord does not have a capacitor exactly like the one pictured, there is no need to proceed on this step. Replace the lower panel. If it does have a capacitor as illustrated, follow those instructions and then replace the panel.

Now plug in the power cord to the wall power outlet. Before pushing the refrigerator back into place you want to make sure it is operating properly. To make sure that there is no "Glitch" during start up, I suggest that you set the temperature control inside of the refrigerator to "OFF" and wait about 3 minutes. After 3 minutes, set the control to the desired temperature (about 37 Deg for Refrigerator and 0 Deg for the Freezer).
If the refrigerator is running, you are finished. Being careful not to kink the water line, push the refrigerator back into place.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alric H from Waynesville, NC
Parts Used:
WR17X11440
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
drinking water cooler leaked at the seam.
ordered replacement part with the understanding that tubing to the water valve could be easily removed. The tubes were carefully removed with some difficulty, and when the new tubes were inserted one leaked. The tube seat was not snug. Therefore a new water valve was purchased. The installation was successful within about 20 minutes. If I were to do the job again, both the water resevoir and valve would be ordered together.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
lam from JACKSONVILLE, FL
Parts Used:
WR57X33326
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Dual Inlet Water Valve
Just fallow video shows that it 123 !
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from LAKELAND, FL
Parts Used:
WR02X45206
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Cracked the head by over tightening the water filter in2 it.
It was much easier than I had anticipated it was going 2B. All it intaled was 2 undue the 2 water lines w/a 1/2 inch wrench, take out the 2 screws on the top of the head on the inside of the refrigerator, then pull it out. I then just slipped the new head in, replaced the 2 screws, replaced the filter (definitely not overly tightening it this time) by putting some waterproof food grade grease, making it much easier 2 push up & turn. After, I went 2 the back of the refrigerator & reconnected the 1 line 2 the fridge & then the other 2 the water supply. "Walla" we were making ice again & able 2 get ice cold water again, also. The entire process took approximately 30 minutes 2 complete & that's bcuz of my limited disabilities. A younger person could probably be able 2 do it possibly faster.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cecilia from NATALIA, TX
Parts Used:
WR55X10942C
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer would not freeze and fridge would not cool after power outages
I used a volt/ohm meter and checked for power to compressor and start run relays, diagnosis- was remove and replace motherboard
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!