Bill from ORO VALLEY, AZ
Parts Used:
WR57X10033
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
Water leaking from bottom of refrigerator
I'm not a DIY-er, and wasn't sure a 20 year old refrigerator was worth the repair, but for $30 I could afford to be wrong. The swap is pretty intuitive, especially in my case since the problem was that the water tube from the valve to the ice maker had detached from the coupling. So I didn't have to cut anything off, just inserted the tube into the new valve. Reconnected the supply line, screwed the assembly back on the refer, and Bob's your uncle. Other than unloading some canned goods to lighten the refer, longest process was finding the right size nut driver in my disorganized tool tray. Be aware, there are NO instructions included with the part. Found a good video on you tube that confirmed the obvious. Glad I took a shot!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Doug from COPE, CO
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Refridgerator stopped making ice
Removed the old water valve from back of refrigerator by using a screwdriver. Pulled water line off old valve that runs into the fridge and inserted it into the new part. I used a pair of pliers to take off water line that runs into the water valve from the house. Screwed the water line back onto the new valve. Took about 10 minutes.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Woobridge, NJ
Parts Used:
WR50X55
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Ice build up in the evaporator coils and had to thaw it out with hair dryer
Cut old thermostat out and installed with heat shrinking wrap and solder the wires and still having issues it might be something else.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cliff from ROCKVILLE, VA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Wrench set
The old solenoid was slow to shut off causing the icemaker to overfill.
Unplug refrigerator and turn water supply off to the ice maker. Remove the screws holding the bottom cardboard-like cover from the lower back of the refrigerator. Remove the water supply line to the old solenoid with 1/2 inch wrench. Unplug the two power supply wires to the old solenoid. Remove the screw that holds the solenoid to the back panel of the unit. After the solenoid is pulled out, remove the output hose with a 1/2 inch wrench. The configuration of the replacement solenoid is likely a little different than the original, but it seems to be rather universal and will fit back into place and perform properly. The new solenoid does not use a compression type nut to secure the output line. It's just a simple push-in connection. The wires may have to be rerouted a little, just keep them clear of the evaporator fan blades Reverse the removal procedure and you're done.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Bakersfield, CA
Parts Used:
WR2X4550
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Broken drive cup in the ice dispencer
Emptied the ice from tray.
Removed the four screws that hold the face plate.
Removed the four screws that fasten drive housing to the tray.
Slid the drive cup into place at the end of the auger.
Made sure the rubber gasket was in place .
Replaced the four screw that hold the housing to the tray.
Replaced the four screws that hold the face plate.
Put some ice cubes in the tray and tested to be sure everything worked properly.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry from Wichita Falls, TX
Parts Used:
WR49X391
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Freezer not cold
I had to defrost freezer first becasue it was heavily iced up. Then I found that one of the heater elements was "open". I removed both of the old heater elements and installed the replacement parts.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ann from LAPORTE, PA
Parts Used:
WR60X30349
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
freezer too cold and refrigerator not cold enough because fan not working
Had to defrost a bit and then was able to remove rear freezer panel by simply removing the 2 screws holding it in place.
Old motor easily removed from its mounting bracket. and replaced with the new. Had to use the two wires sent with the motor. I clipped off the male connectors and joined them with wire splicers to the black and red wires clipped from the old motor. Then reinstalled.
The replacement motor works great. I was afraid the old fan blade might not fit but it slid on perfectly.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from CLIFTON, NJ
Parts Used:
WR60X187
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Fan would not turn when the refrigerator came on all the time. Would physically have to turn the fan blades.
Did not do the repair because the unit arrived damaged. The packaging was in good condition. The plastic around the plug in shattered, and some of the plastic was inside the motor. Very good, and fast on adjusting the order.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from San Marino, CA
Parts Used:
WR2X4901
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Door wouldn't close properly
First we removed the door. Then we had to hammer the old part off including the old rivot. We fould a screw that fit and put this piece on. We held the door in place and screwed the hinge on the main unit.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeff from Venice, FL
Parts Used:
WR2X4901
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Door Not Closing Tightly + Staying Open
Turned off water to ref , removed bottom kick plate , got a towel and disconnected the water line plastic fitting and un screwed the (2) tube clamps un screwed the coupling and ((carefully )) slid out the tube from the compression ferrels ! ( Be careful and do not break or distort them + remember exactly the order they are removed ! Slid the protector spring shroud from the plastic tube , took ogg the top hinge cover then remover the top hinge . Carefully lifted the door off feering the plastic tube through the bottom hinge with my foot ! Got the door off removed the bottom hinge + put the new on on, then removed the door cam which was broken on the bottom of the door , lifted the door up and carefully fed the water line through the new bottom hinge . Attached the top hinge and reassembled the rest same as I had dissambled it . Turned on water ( checked for leaks ) ! All working 100% a-ok ! This company is the best ! Ordered the part at 1 pm and had the part at 2 pm the following day many thanks : )
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randall from Cumming, GA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Wrench set
Water valve for ice maker leaking
Other than having to bend the bracket 90 degrees it was an easy install.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Margaret from Virginia Beach, VA
Parts Used:
WR57X10033
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Ice maker would only make very small and very few ice cubes.
After determining that the ice maker on this relatively new refrigerator would make ice cubes if it received the proper amount of water. Ordered the valve and received in a couple days. Using a nut driver, removed the cardboard cover from the back of the refrigerator. Removed one screw holding the valve bracket to the fridge and removed another screw holding the water supply line and the water line to the ice maker in place. Pulled plug on fridge and removed 2 wires from valve. Removed inlet and outlet lines from old valve and reversed the process installing the new valve.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Newport Beach, CA
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
The fresh food door on the refrigerator would not stay closed
First I took everything out of the fresh food door, then I removed the top hinge cover using a philips head screwdriver, and a nutdriver for the two screws holding the upper hinge. Lifted the door off the bottom pin, and placed it on the floor. Then took off the bottom hinge and used the Dremel tool to grind off the rivet holding the broken door cam on the bottom hinge. Used a nut and bolt to hold the new cam in place, and put the lower hinge back on. Then replaced the other cam on the bottom of the door itself, using the nutdriver. (Be sure to buy two cams, and have the bolt and nut to replace the rivet). Reinstalled the bottom hinge, put the door on, replaced the top hinge, and presto! Works great! Thanks to the others on this site for their stories - really helped make it an easy and quick repair!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Franklinville, NJ
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
worn/broken cam , door doesn 't self close
Remove contents of door , Remove top hinge cover - phillips screwdriver , remove top hinge screws ( 2 ) - socket wrench , lift door off lower hinge pin , lay door on edge , remove cam retention screw ( 1 ) - socket wrench , remove broken cam , install new cam , apply vasaline to cam and hinge pins , repeat above steps in reverse . Door now self closes .
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Renton, WA
Parts Used:
WR13X10020
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Closing cam disintegrated
Removed everything from the refrigerator door. Removed the screw holding the cover over the top hinge. Removed the two (8mm) bolts holding the top hinge to the refrigator. Removed the door. Removed the plastic grill/cover and the two (8mm) bolts from the lower hinge assembly. Installed the new hinge assembly. Replaced the closing cam (included in the hinge assembly kit) on the bottom of the door. Put the door back on the lower hinge. Installed the upper hinge. Adjusted the door and tightened the bolts on the upper hinge, and replaced the hinge cover. Done!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!