Refrigerator and freezer drawer would not maintain set temperature
Condenser fan motor was running slow. This was not a problem included in your list of possible problems. I thought that maybe the capacitor was bad but have no way to check it. So I ordered one. when I received it, I installed it. That was not the problem. So I ordered a fan motor and installed it. That was not the problem. So finally I ordered a control board and installed it. That solved the problem. So maybe you should put "cond.fan motor runs slow" in your list of possible faults and what causes that problem. Capacitor was easy to install, simply remove the cover plate, flip off retaining wire, unplug the capacitor and replace. Fan motor was a bit more difficult. It must be removed from mount after fan scroll is removed. Remove one screw that holds scroll, bend the top down and remove. Then pull hard on fan blade to remove it. It must be installed on new motor. Two screws in frame mount can be removed with some effort if you have a 1/4" drive ratchet with a Phillips screwdriver bit. Then pull frame open and install new motor. Push fan blade on new motor shaft hard. Replacing control board was easy. I used a pair of long nose pliers with 90 degree bend to get mounting pins closed to pull board off.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- TIMOTHY from SPRING VALLEY, CA
- Parts Used:
- WR60X10220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
no ice being produced & on Hot point dbl sided frig panel between freezer & frig very warm
Water still came out the front when pressed, but no ice. After removing the Ice container, & the top shelf I noted the icemake inlet was iced over. I turned off the icemaker, turned down the freezer temp, & allowed Ice to melt, but problem returned. I next removed the back bottom cover & cleaned the condenser coils, & drain pan; they were extremely dirty. Then I noticed the condensor fan was not on. After getting the nomenclature plate info off the condenser fan motor I left the back cover off, & put an external fan to blow on the coils as a temporaty fix until I could get the part & replace it. During that time the refrig functioned normally. 3 days later my condenser fan motor I ordered from Parts Select arrived & I installed it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kirk from Springfield, MO
- Parts Used:
- WR60X10220
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Socket set
Condenser Fan was shot.
I followed the instructions in the video regarding removal, repair and reinstall. It all went as the video said, except for the reinstall. The rear tab did not snick into place like the one in the video did, and it was extremely difficult to see whether or not it was inserted properly. I ended up inserting the rear tab by feel, and then I had to hold it in place while I stretched the front part of the frame to line up the screw hole in order to reinsert the screw. I had to have my wife hold the flashlight while I did that in order to see. Other than that, the repair went well, it is working like a charm, and I know I have a quality GE part in my refrigerator again! Many thanks to Partselect for their speediness in getting the part to me and giving me the needed information in getting the repair done! I will shop here again.