Customer:
Marie from Elk Grove Village, IL
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
My ice breaker started leaking and making noise anf the stripper broke.
I ended up needing to order a new ice maker because the one I had is discontinued. I'm a 65yr old grandma and I did it myself!!!! The hardest part was finding the tool to loosed the nuts. I took the old one out and just put the new one right in it's place. Easy as pie.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from PLYMOUTH, MA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Ice maker needed replacement
Unplug refridge then loosened two bolts holding old ice maker. Lower then unplug and removed. Plugged in new harness and tightened two bolts to secure new ice maker. Plug in frig and wait for ice.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lynn from MOUNTAIN HOME, ID
Parts Used:
WR30X10093
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Callaway, FL
Parts Used:
WR30X10093
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers, Wrench (Adjustable)
Ice maker arm disconnected from frame causing problems.
The icemaker arm disconnected from the metal frame. This caused the icemaker to cycle and the heater to come on and stay on until the plastic parts melted causing a mess and stink. This action melted the ice and then the water fell through the frozen items in the freezer and refreezed in the lower portion. OK, I remover the dead icemaker and tossed it away. I installed the new icemaker and the wiring harness didn't fit right (way to long). I retrieved the old icemaker and removed the wiring harness from it. I removerd the new ice maker and installed the old wiring harness to the new icemaker. I then installed the new icemaker, plugged it in and turned on the power. No water, I ordered the dual solenoid water valve, installed it with difficulty (another story) the turned on the power. I reinstalled the ice bin and found it didn't fit. The icemaker was to low and couldn't be adjusted, 1/4" higher would have been great. I shoved in the bin anyway, I was out of ice for my scotch, and it started making ice.
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rene from HEBER, CA
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers
condenser icing refrigerator warm freezer ok
follow the easy instructions replace 3 temperature sensors cut the wires and crimp them with new sensor and it works like new
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ted from Harrisonburg, VA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
icemaker stripper fall a part
instalation was very easy - but the part was 3/4 inch to long and a 1/32 inch to wide.Trimmed it with the "faithfull"
Dremel and it works!The instalation part of the "job" was less then 10 min.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Amanda from New Albany, MS
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker didn't work.
Replaced icemaker assembly. Only 3 Phillips screws to remove the old assembly. Pretty much an exact swap. Was easy to replace but the connecting cable on the new replacement assembly wasn't very easy to make fit. Had to force it into a location that would be out of the way and allow everything to operate properly. That connecting cable should be more flexible and adapt to the fridge a little more friendly.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eli from Buford, GA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker
Remove ice maker out of fridge; remove 3 screws
replace defective part re-install all components 30 minutes later " magic ice again. Very easy repair most important low cost. Thanks "Parts Select"
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Russell from GLEN, NH
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set, Wrench set
noisy evaporator fan motor
Replaced evaporator fan motor, and this solved the whistling noise that had developed. Reviewed and followed the removal and installation instruction video as closely as possible. This was very helpful, with a few additions. For the model PS123NGPBBB GE refrigerator/freezer, there were a few differences from the video. There a was an additional cover panel that was positioned vertically at the back of the freezer compartment below the auger motor assembly. It was necessary to remove this cover (4 screws) to gain access to the auger motor cover screws. The unit also has a different light configuration with 2 lights. I found it helpful to remove these light bulbs and the corresponding light fixtures in order to remove the evaporator motor assembly. As mentioned in the video, it was necessary to cut the 4 wires from the wire harness of the new motor, and use butt end connectors to reattach these wires to the corresponding wires in the unit. Total job took between 1 and 2 hours, and the motor change solved the noise problem.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Riverdale, NJ
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Water leaking and freezing everywhere. Weird shaped ice cubes, more like chunks which jambed the dispenser.
First removed the two screws that holds the old ice maker in place. Unplugged it. The freezer compartment was too narrow to allow the unit to slide out or turn in any other direction. Had to also remove the two front screws from the left side ice bin track and swing it down. The door opening was also too tight. Scratched the plastic door jamb putting the new unit in but other than that all is well and functioning well.
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mary from WESTON, CT
Parts Used:
WR30X10093
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker stopped working
Installation could not have been easier!
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hugh from LADSON, SC
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Ice Maker stopped making ice.
Did the repair just as the instruction said, once I read it. The part I didn't read was that if the plug was under the ice maker, you had to take the wire out of the clip on the side. So, had to dismount ice maker, unclip wire, remount maker, plug it in. Still under 30 minutes. Thank you.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rich from san marcos, CA
Parts Used:
WR23X21444
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
No ice from door, but did have water
I got the wrong switch before so just need to put the right 1 in. Super easy, pop off old, plug in new, click back into place. Done. REALLY REALLY EASY for anyone to do
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Harry from DURYEA, PA
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Anaheim, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
The icemaker quit making ice and the water started forming on the bottom of the ice bucket.
First I removed the electrical plug from the back of the freezer that plugs into the icemaker. I then removed the two hex head screws that hold the icemaker to the wall of the freezer and removed the icemaker. I removed the plastic cover, which incidentally protects the gears, by prying it off with a srewdriver. I removed three small nuts(7mm) which holds the internal cam in place. I removed the cam by pulling it off the shaft. Once I got the part from you folks I reversed the procedure that I just mentioned, and put the icemaker back together. It works great. The part with shipping was around $16.00. A new icemaker was roughly $159.00. If I would have called a technician it would have cost around $300.00 to repair.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ZIS420NHC