Greg from ANKENY, IA
Parts Used:
WR32X10910
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
The middle support for the vegetable door roller wheels broke
Removed drawers, lifted out old frame assembly ( no tools ) removed and cleaned old glass from assembly.
Carefully screwed old rollers ( x4 )into new frame, then placed old glass in new frame, repositioned frame into refrigerator and then repositioned drawers in frame.
20 minutes , no issues
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from LAKE PLACID, NY
Parts Used:
WR71X11063
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Replace butter compartment on GE Profile
It just snapped in. Fit perfectly. Excellent service.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karen from Salisbury, NC
Parts Used:
WR71X11045
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
I dropped The top left bin and it cracked
Popped it up and popped new one on
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from COLUMBIA, SC
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
elissa from ASHBY, MA
Parts Used:
RPWFE
Difficulty Level:
Very Easy
Total Repair Time:
More than 2 hours
Replaced thermistor 5.2 ohms of resistance
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
QUOC-LOC from LYNN HAVEN, FL
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kent from Bartlesville, OK
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from Burlington, NC
Parts Used:
WR12X23646
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Freezer door handle replaced.
Freezer door removed with two allen screws.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sara from White Plains, NY
Parts Used:
RPWFE
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Water filter needed changing.
Snap filter into place while holding the filter slightly away from the refrig. When filter snaps into place, push it towards refrig into place.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
larry from lisbon, ME
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
extreme frost build up inside in back of freezer,also veggies were freezing in the fridge draw
no brainer,watched the video,worst thing was to thaw the freezer,it was realy frosted,works like new,very happy thank you.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Troy from Dacula, GA
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Food section of fridge always warm
Located temperature sensor on condenser in the freezer section( as per instructional video ). Cut off bad sensor with wire cutter then soldered on the new sensor and sealed with electrical shrink wrap.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John J. from Deland, FL
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
freezer no cold enought
as per video- follow all of the videos and u r going to save a lot of money tx partselect im glad I found u guys ps only order from partselect.com they only ship the correct parts remember look at the video select the symptom and buy as per video tx again problemsolved
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Island Lake, IL
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
frige too cold
changed sensors did not repair problem,replaced damper with mechanical damper fixed problem.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laura from Brentwood, MD
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
freezer and refrigerator wasn't cold
Replaced all the sensors in both the feezer and refrigerator.Even though it colder now it still is not cold enough.Freezer won't freeze items but is cold and refrigerator still not real cold
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brandon from Bruceton Mills, WV
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Defroster stopped working and iced up evaporator coil
I have a GE Profile French door refrig. It's only about 4 yrs old and the defroster stopped working. I read the other repair stories and was able to narrow it down to either the temp sensor, defrost timer, or main board. The refrig section was up to about 47 degrees and freezer was around 25. I could tell it was trying to cool but couldn't. So I tried the temp sensor first. I cut and spliced the new sensor on the outlet of the Evap. Coil and it took about 15 mins. Turned refrig back on and waited. The coil started to ice over after about 5 hrs I left the back panel off so I could see if and when then heater kicked on. After about 8 hrs I looked in and saw a faint glow and water trickling down and running out the drain. Turned out the sensor was bad and wasn't telling the main board it needed to defrost. I would try the sensor if you are having the same issues before spending a lot of money on the main board, defrost heater and or timer.
Was this instruction helpful to you?
Thank you for voting!