Customer:
James from PLYMOUTH, MA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Ice maker needed replacement
Unplug refridge then loosened two bolts holding old ice maker. Lower then unplug and removed. Plugged in new harness and tightened two bolts to secure new ice maker. Plug in frig and wait for ice.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
KEITH from WINDER, GA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
broken outlet valve
All the repair people was on the money . I read them all .1--- NO paper work with new valve (.no instructions) ..2--- bracket is not the same .. I reversed my braket and it worked fine .you do not have to bend bracket.3--- It will take a day or so to start making ice..4--- the plastic nut is no longer needed on the new type outlet valve ....5--- the new outlet valve looks a little different from the old valve. WORKS GREAT ..
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rickey from DUMAS, AR
Parts Used:
WR55X24064
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugged it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ronald from springfield, VT
Parts Used:
WR60X31522
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
noisy fan
removed cover over fan, four screws. removed two screws ,that holds fan in place,removed two more screws that holds fan in bracket,then reinstalled
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from SEATTLE, WA
Parts Used:
WR60X31522, WR02X12008
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
the evaporator fan motor was making noise sometimes, but not all the time during the cooling cycle
after watching how easy it was to get to the evaporator fan motor on u-tube, I took out the motor to inspect it......the motor had about 1/8 inch shaft end play and a slight amount of play on the shaft, the rubber grommets looked OK.....I then put it back together......since the motor was the only moving part in this location I figured it had to be the part making the noise, so I ordered a motor and 2 grommets …...the replacement motor also had 1/8 inch end play on the shaft, but no play on the shaft....I installed the new parts and it has been a week now and no noise.....SUCCESS!...….the shaft on the motor protrudes from the motor, and the fan is mounted about 1 1/4 inch away from the bearing in the motor and the fan is unsupported, so I ASSUME that the slight amount of play on the shaft caused some harmonics which caused it to make noise some of the time, but not all of the time......
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karen from SAN ANTONIO, TX
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker filled too full and ice froze in the basket and a piece was broke on the icemaker itself.f
My son did it , and showed me what he did when he was finished.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marie from Elk Grove Village, IL
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
My ice breaker started leaking and making noise anf the stripper broke.
I ended up needing to order a new ice maker because the one I had is discontinued. I'm a 65yr old grandma and I did it myself!!!! The hardest part was finding the tool to loosed the nuts. I took the old one out and just put the new one right in it's place. Easy as pie.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edwin from BELLINGHAM, WA
Parts Used:
WR22X10068
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
replace broken door dairy
a-ok. no problems
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bradley from Cedarburg, WI
Parts Used:
WR60X10207, WR02X12149
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Condensor fan blade cracked, blade was sheared off.
First, remove the cardboard cover on the back, lower portion of the refrigerator.

Next, locate the condensor fan motor assembly and blade. (Right side as you are facing)

Using a pliers, hold the shaft to keep it from turning and prevent damage to the motor. Using a screwdriver, slide the old ring compression on the blade shaft toward the motor (away from the fan blades) to loosen.

Remove old blade from the shaft by firmly grasping the motor shaft with a pliers (to prevent from damaging) and pull the blade assembly off.

Reverse the above steps to attach the new blade.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ted from Harrisonburg, VA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
icemaker stripper fall a part
instalation was very easy - but the part was 3/4 inch to long and a 1/32 inch to wide.Trimmed it with the "faithfull"
Dremel and it works!The instalation part of the "job" was less then 10 min.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Callaway, FL
Parts Used:
WR30X10093
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers, Wrench (Adjustable)
Ice maker arm disconnected from frame causing problems.
The icemaker arm disconnected from the metal frame. This caused the icemaker to cycle and the heater to come on and stay on until the plastic parts melted causing a mess and stink. This action melted the ice and then the water fell through the frozen items in the freezer and refreezed in the lower portion. OK, I remover the dead icemaker and tossed it away. I installed the new icemaker and the wiring harness didn't fit right (way to long). I retrieved the old icemaker and removed the wiring harness from it. I removerd the new ice maker and installed the old wiring harness to the new icemaker. I then installed the new icemaker, plugged it in and turned on the power. No water, I ordered the dual solenoid water valve, installed it with difficulty (another story) the turned on the power. I reinstalled the ice bin and found it didn't fit. The icemaker was to low and couldn't be adjusted, 1/4" higher would have been great. I shoved in the bin anyway, I was out of ice for my scotch, and it started making ice.
5 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Elkhart, IN
Parts Used:
WR17X11889
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Freezer shelf bracket broke. .
Took the bracket out of box and install it like the video showed me..very easy to install..
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Boyd from Blaine, WA
Parts Used:
WR09X20002
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Could not adjust temperature
Replaced temp controller
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry from DOUGLASVILLE, GA
Parts Used:
WR09X20002
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Fridge never cuts off.freeze everything inside of fridge.
To remove the temp sensor.2 Phillip head screws not remove the cover inside fridge .the temp control knob cover.removed that and unplugged switch.installed new switch.reinstalled cover.
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sophie from WASHINGTON, DC
Parts Used:
WR17X11890
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Broken freezee door shelf
Click shelf into place!
3 of 4 people found this instruction helpful.