- Customer:
- Anthony from Riverview, FL
- Parts Used:
- WR02X10740
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
frig door kept slamming into cabinet
took the old stop off put the new stop on
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anthony from Painter, VA
- Parts Used:
- WR72X10086
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
broking slide
replace the bar lift top off
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from Redmond, WA
- Parts Used:
- WR24X10186, WR24X10187
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The refrigerator and freezer door gasket's were leaking
The repair is very simple, the gasket sits in a channel in the door. Just start with a corner and pull the old gasket out. Once you've removed the old gasket, push the new gasket into the same channel. Make sure you've completely pushed in the new gasket all the way around the door. It's as simple as that. The repair takes less than 5 minutes per door.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from Farmingdale, NY
- Parts Used:
- WR55X24064
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Both the fridge aqnd freezer would not get cold.
Easy. Followed the video instrucations. the part was right there next to the compressor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jules from Crowley, LA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
failed light switch
I started removing the switch by prying on the right side with a screwdriver, when it emerged enough I used pliers to finish removing it. I then unpluged rhe wires from the bad switch and pluged them on the new switch and "poped" it into the hole.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- christopher from collegeville, PA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
no light in freezer
Connected the 2 wires and pushed in the switch until it clicked.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anthony from District Heights, MD
- Parts Used:
- WR60X10172
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Noisy evap fan motor
Simply unplug fridge, remove air duct mounted on rear panel, release panel itself, pull fan blade off, disconnect grounding wire, detach fan motor bracket, disconnect wire harness to release fan motor, install new fan motor and reconnect, secure with bracket, reconnect grounding wire, reposition fan blade onto motor shaft, reinstall rear panel and secure screws. Remount air duct and plug appliance back in. This is the second motor that was replaced since 2002. The 1st motor dies after 5-6 years.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Andrews, NC
- Parts Used:
- WR9X502
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Refrigerator and freezer too warm
1) This is a built-in refrigerator with the compressor, coils, etc. at the top. Turn off the breaker to the fridge. 2) Remove the front panel off the top (just push up and pull out). 3) Removed 2 screws to the old timer and carefully remove the plug. Plug the new timer in and screw in. 4) Since our fridge was heavily frosted up, we moved everything to another refrigerator and coolers and kept the refrigerator off until all panels were room temperature. 5) If you haven't cleaned the coil in a while, vacuum it with a soft brush attachment. 6) Turned back on and the refrigerator is cooler than ever!
Was this instruction helpful to you?
Thank you for voting!