Customer:
Victor from Fort Myers, FL
Parts Used:
WR23X37285
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
light in freezer section not working
Using plyers Pulled old switch down and out. Put new one in and pushed new switch up into position. The switch plugs into the contacts, no wiring needed. Worked like a charm. You saved me 200 dollars GE repair bill. Thanks
6 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Reese from Coconut Creek, FL
Parts Used:
WR9X502
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
defrost timer was bad
repalaced the old one with the new one. easy
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edmund from Bethel Park, PA
Parts Used:
WR60X177
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Compressor fan bearing worn. Refrigerator was manufactured 9/78/
I followed the instructions verbatim as others explained. I did it step by step exactly as instructed, The timing was almost exact no more than 30 minutes. I removed the fan the night before the delivery of the new fan and used a small desk fan to cool the compressor. It worked fine in one half hour my freezer read a perfect zero. Thanks for all the help
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from St Johns, FL
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
water leaking on floor from ice maker valve
Replaced single outlet valve for the ice maker
Was this instruction helpful to you?
Thank you for voting!
Customer:
paul from east hanover, NJ
Parts Used:
WR23X37285
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
refig light did not work
per your instructions
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert L. from Eldred, PA
Parts Used:
WR60X114
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Noisy fan
Emptied freezes, turned off power, took floor of freezer out [4 screws ], took two screws out of fan mounts and replaces fan. Reassembled by reverse process. Simple
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Mechanicsville, VA
Parts Used:
WR60X177, WR60X117
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Inside of refrigerator very hot
Noticed the fan was not working properly and went online and found out that was the cause. I immediately ordered the part that night at 8:21pm and received the motor and fan blade the next day. I flipped the refrigerator on its side and removed the 3 hex bolts, took off the fan blade first and removed the wires from the motor. I put in the new motor and then added on the new blade and put the 3 hex bolts back on and the wires. The whole process took about 30 minutes. Piece of cake.
Was this instruction helpful to you?
Thank you for voting!
Customer:
eduardo from oakland, CA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
water leaking
i swaped the valve it was very easy, but that did not take care of the proble :(
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sylvia from Marrero, LA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
Ice maker stopped working, no ice made
I am a 68 year old woman that had hernia surgery (6) weeks ago so my friend did the replacement. I showed him the video of how to fix it and I felt like I could have done this myself because all you had to do was loosen a couple of screws to get into the back of refrigerator and pull out the bad part. It was like plugging in my cell phone for recharging I do everyday. Unbelievely easily. The price was great also. We priced part locally and they wanted $30.00 and your part was $18.25 plus shipping. Shipping was unbelievely quick also. It was shipped within (2) days after ordering. Very satisfied.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carlin from Willits, CA
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
ice maker wasn't working
removed old valve, installed the new one. ice maker back to making ice.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Phillip from Atlanta, GA
Parts Used:
WR57X10033
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Ice maker was not getting water
Ordered the part from "parts select". Removed old part, installed new part by unscrewing the old switch, simply cutting supply hose ...pluging in the new part and re-attaching water supply line. 10 minutes at most.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry from West Seneca, NY
Parts Used:
WR9X502
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Frezzer would freeze up, refrigerator stayed cold, solved the problem. Now the refrigerator seems to be running more than usual.
Checked the defroster coil which is located behind the rear panel in the freezer compartment, it was still working. Followed the schematics down to the defrost timer, which is located in the lower front of the refrigerator and tried that. Plugged in the new part and the problem is solved.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Albert from New York, NY
Parts Used:
WR2X8474, WR2X4754
Difficulty Level:
Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
leak causing ice build up in freezer compartment
I had to defrost large chunks of ice from the rear of the freezer compartment and tried reactivating the ice maker several times before deciding to order the replacement fill tube grommet and clamp. This was very stressful and complicated to accomplish while trying to avoid food spoilage, and consumed a lot of time. It involved removing the ice maker and various panels, plus disconnection of 2 electrical plugs, then using a hair dryer to melt ice build up. The installation of the new parts was quick and simple once they arrived in the mail, and this appears to have solved the leak problem. The fill tube slides easily into the grommet and the clamp, tightened with a screw driver, secures the water feed line on the other end. Fill tube must be carefully threaded through rear panels and into the ice maker receptacle and the grommet needs to be pushed hard and wiggled in order to seat properly in the rear surface of the refrigerator.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Dahlonega, GA
Parts Used:
WR57X10033
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench set
did not work, not sure what the problem is
water runs in now but still does not make cubes. just keeps dripping until I shut the water off.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from Spring Valley, IL
Parts Used:
WR60X177
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set, Wrench (Adjustable)
The motor was making a thumping out of balance sound.
Naturally you have to push the frig from the wall and unplug it form the wall outlet and while you are removing and installing the old motor and installing the new motor. Do not open any of the frig and freezer door untill you are finished and you plug the power cord back into the wall outlet. Remove the lower back panel with a screw driver or a 5/16th hex driver. It is a kind of carboard. Once all the screws are out of that panel pull the top out from behind the steel above and then pull it out from the bottom and set it aside. Unplug the power line off of the motor. There are 3 separate brakets holding the motor in place. 1st remove the fan from the motor by romving the finger nut off the motor shaft and then remove the 1st bracket screw from the bracket all the way. Then use a light to see the other 2 screws and you will see that you do not have to take them all the way out like the first one. Just loosen the other 2 and then turn the motor and brackets counter clockwise and then pull the motor and brackets all out as one from the right hand side of where the brackets were mounted. I took the motor and brackets to the counter and removed te brackets from the motor and installed them to the new motor making sure that the bracket with the one screw hole in it is mounted at the right place so that when you reenstall the motor and brackets will let the motor wire connector be the closest to the outside where you can replug the power cord back onto the motor. Install the fan onto the new motor with the new finger nut that comes with the new motor. replace the back panel and pkug in the power cord fot the frig and let it run. Mine ran a lot quieter after the new motor was plugged in. Have fun if you have to do it. It is worth it.
Was this instruction helpful to you?