Models > TFX24PRAXBB > Instructions

TFX24PRAXBB General Electric Refrigerator - Instructions

Jump to:

All Instructions for the TFX24PRAXBB
106 - 120 of 443
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Walter from Wyndmoor, PA
Parts Used:
WR17X4312
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker crushed all ice and would not make cubes. Pushing the switch and changing to cubes did not work.
Removed old ice bucket with auger. Unscrewed front plates that form the front of the ice bucket. Replaced the front plates on the new part (ice bucket and auger). Replaced new assemblage. It took about 20 minutes. Had to empty ice out and put in a temporary cooler for storage. Bigger problem than the repair was diagnosing what was wrong. Pushed disagnose button and it said ice maker was working normallly. Careful examination of the ice bucket removed from refrigerator showed spring out of place on long metal rod that protrudes from the back of the ice bucket and fits into a square hole in back of refrigerator. Examined other end of rod that engages with plastic parts that run the ice auger and ice crusher mechanism. A piece must have broken off. That was the problem. Refrigerator ice maker now works fine as originally designed. Push crudh the ice crusher engages and you get crused ice. Push cubes and the icemaker crusher slides out of the way and you get cubes.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
CYNTHIA from NEWARK, DE
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Wrench (Adjustable)
Refrigerator door won't close
First I removed the top hinge of the refrigerator door and then lifted it off the bottom assembly. I had to turn the door on its side to work on the bottom where the broken part was located. I unscrewed the bottom assembly and replaced the broken part with the new door cam. Put it all back together and now the door closes but must be manually pushed to close. When the door was working properly it would shut automatically when released from any position. I think I need to install an additional part - maybe a shim? to make it close automatically. That will be another story.
This was a fairly simple jog to do but since I did not have the proper tools it did take me longer than usual to remove the bolts. I'm happy I did it myself and saved a big repair bill! Thanks to the people at PartSelect.com.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kurt from Aurora, IN
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Door would close by its self.
After reading the stories here, I purchased one door closing cam. After getting into the problem area, I realized I needed 2 cam, so I put the door back together and ordered another cam. If you have this problem, buy 2 cams.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donnette from Flagstaff, AZ
Parts Used:
WR2X4901
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Door would not close due to broken closing cam
First, I was glad I read other posts on this repair as I would have only purchased one of the replacement cams when I needed two! I removed the top door hinge with a screw driver (cover) and small socket set for the door hinge. I then removed the door and removed the bottom hinge (socket set). The bottom hinge had a small rivit that held the bottom cam in place. I used a hack saw to cut off the rivit and replace the cam and secured it with a small machine bolt and nut. I then laid the door on its side and removed the top am from a bracket attached to the bottom of the door. I relaced the cam (second one) and reinserted the screws. I reattached the bottom hinge and then placed the door on the bottom hinge pin. I then held the door in place while inserting the top hinge pin bracket into place and retightening the top screws. I replace the cover with a screw drive which was the ahrdest part in trying to find the hole the small screw gets inserted into. DONE!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
steve from winthrop harbor, IL
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
door not closing corecyly
took top bracket off--then removed door--took
bottom bracket off bottom of door and replaced
door closing cam and reasembled---a piece of
cake
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ERIC from EL DORADO HILLS, CA
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
door would not shut
Like the rest of the other statements it was easy with 2 2X4 pieces of wood to block the door up. The other suggestion about buying two of the pieces was a good idea. Once I took off both the top and bottom pieces they were both worn out and it was easy to replace them both at the same time. The door is working good again and shuts on its own.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from moundville, AL
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Door wouldn't close tight.
I placed books under the door until I had enough to hold the door up about 1/2 inch higher then when it is closed. The books and the magnetic gasket will hold the door, JUST DON'T TRY TO OPEN IT TILL YOU'RE THROUGH. That's about how high the cams lift the door when opened. I removed the two screws holding the door stop. Then removed the two screws holding the lower hinge pin.

It takes two of the cams

and the bottom one is riveted to the hinge. I used a grinder to grind the rivet so I could tap the pin out holding the cam. Put the new cam on and put the pin back in. I didn't put a new rivet, just gravity should hold it. I put the second cam on the hinge pin and one of the screws on the door stop holds it in place after you slide the hinge pin back into the door and replace the screws in the bracket then the door stop.
Make sure your lower door gasket didn't get damaged while the cams weren't working because the door wasn't being lifted up when opened.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Lecanto, FL
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Door Would Not Shut
Same problems as already described .... door would not close, plastic bits on floor, angry, ready to throw-out 15 year old “dog” and blow at least $1,000 on a new appliance!

This repair is dead easy. Remove the two bolts holding the top hinge and lift off the entire door. Don’t be surprised if the original Riser Cam has virtually disintegrated, mine was a wreck. Remove two bolts that retain the old flat metal “shim” and fiber “gasket”.

Fit new Riser Cam and re-use old shim and gasket. Replace door on dome-shape bottom hinge mount and then re-fit top hinge.

If in any doubt order new shim and gasket along with the new cam riser. Or, do as I did, and “manufacture” either of these parts from scrap material found in the workshop ....
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Woodland Hills, CA
Parts Used:
WR2X4901
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set, Wrench (Adjustable)
Fridge door stopped closing.
The plastic door closing cams had broken after 17 years of use. It was tricky figuring out how the new cams fit as the old ones had disintegrated. Also you need 2 cams - not one. I first ordered only one. A detailed parts diagram would have helped. First unscrew the top door mount cover and then the top door mount. The fridge door then lifts up and off the lower door mount. Next is the hardest part - drilling off the old pop rivet which held the lower cam. The lower door mount had to be removed to get at the underneath of the pop rivet, and a bench vise was handy to hold it as I drilled off the old rivet. Then you need small stainless steel nut and bolt and split washer or lock nut to replace the rivet. Next unscrew the old upper cam from the underneath of the fridge door and replace. The large hole in the cam goes through the door hinge pins. The two plastic cams should interlock in a way that makes the door swing close. Anyway, now the door works fine.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brian from Louisville, KY
Parts Used:
WR2X4901
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Door had sagged, wouldn't close well.
At first, I noticed the refrigerator door didn't close at the same level of the freezer door. I started to adjust the hinges and noticed a chewed up black 'washer' at the base of the door hinge. Ppartselect.com was awesome, in that I easily found the schematic of my fridge, and the part I needed. Ordering was a snap, and it came to the house pretty quickly.
Installation, first raise the door up as high as you can, then scotch it with wood blocks (closed door). This takes the pressure off the bottom hinge you must remove.
Taking the hinge off is a snap, but then the problem presented itself. The old door closing cam was riveted to the hinge. I couldn’t get the old one off! I ended up taking it to the garage and breaking out the Dremmel tool with the abrasive cutter (the one that will cut through nails. I ended up cutting off the rivet. This was a pain.
I then found a small nut/bolt and put the new piece on, then put it back into place and removed the blocks. Works good as new. The toughest part by far was getting the old cam off… but there may be some easier way to get the rivet out that I’m not aware of.
Good luck.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Hawthorne, NY
Parts Used:
WR2X4901
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Wrench set
door didn't close on its own..
Removed door off hinge , remove bottom hinge, drill out rivet, lift off old cam & replace with new cam ,add new 1/4' BOLT(NOT SUPPLIED) to location where rivet was, reinstall bottom hinge & door ,check alignment, works perfect.

Thanks
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Louis from Anchorage, AK
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
door didn't close by itselt
Placed blocks under the refrigerator door to take weight off the lower hinge pin. Removed the hinge by removing two screws into the refrigerator and two screws into the bottom of the door itself. This allows the hinge to be removed so the old nylon "closer" pieces can be removed (the one attached to the refrigerator has a rivet holding it in place so that has to be drilled out and replaced with a 3/16 inch bolt and nut). After re-attaching the nylon "closer" to the refrigerator side of the hinge and placing all the shims back in place, I re-attached the hinge to the door first, then the half hinge to the refrigerator. Had to line up the holes, tighten the screws and presto, the door closes like it was new again.

The freezer door side is more difficult as there are wires and a water line to work around.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jennifer from Holt, MO
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
Door would not stay closed
BUY TWO CAMS! Just like the others, both of the cams were shot. My husband & I did this ourselves & have NEVER attempted appliance repair before.
We propped the door up high enough to access the bottom hinge piece on the fridge & removed using socket. Removed the cover from the top hinge. Slid door down off the top hinge in able to get to the cam on bottom of door. Replaced this cam 1st in order to get door back on while worked to get the old cam off hinge. As others posted, this is rivited on. Used grinder to grind off rivit & hammer & punch to punch out. Attached new cam with bolt & nut found in our tin of leftovers. Inserted hinge into door & reattached to fridge. DONE! Not hard at all & didn't even argue the whole time.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from Dallas, TX
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Broken cam pieces, top and bottom
Removed the top hinge cover held by one screw. Removed the top hinge held by two screws and them lifted the door up and off the bottom hinge. Laid the door on the floor and replaced the cam piece from the kit on the bottome of the door. That required removing one screw and losening another. Removed the lower hinge (two screws) and replaced it with the new one in the kit. The lower hinge includes the other cam piece. Lifted the door onto the lower hinge and then replaced the top hinge and cover.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rodger from Brunswick, OH
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Door wouldn't close with out help.
Removed four screws at bottom of door, while someone held the door in place replaced the upper cam (there are two) applied some silicone plumbers lube between the mating surfaces and tightened it up. Works like new bottom cam was only slightly worn. P.S. Remove everything from the door first.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TFX24PRAXBB