TBF14AGB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Jack from Lake Helen, FL
- Parts Used:
- WR57X10033
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set, Wrench (Adjustable)
Mounting bracket did not fit. Retainer for water input looked like a thread protector.
Put bracket on workbench and hit two or three times with hammer. Glad I did not remove water inlet retainer from part, it can very easily be mistaken for a thread protector.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roscoe G from ROCHESTER, NY
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from Eugene, OR
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The door activated light switch was missing.
Pulled the two wires out from the access hole in the lower part of the refrigerator. Put them in the spade connectors on the new switch, and pushed the switch into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paulette from Crandall, GA
- Parts Used:
- WR57X10033
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Had never installed one before and was not sure which was top or bottom. The piece was made different than the original
Unhooked power to valve
Removed old valve by taking out 2 screws.
Used adjustable wrench to remove water lines. Then reversed and hooked everything back up
Removed old valve by taking out 2 screws.
Used adjustable wrench to remove water lines. Then reversed and hooked everything back up
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Patricia from Sylva, NC
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Bad switch for door prevented interior light from coming on
Just as your video described, although due to the age of the fridge, it took a bit longer to remove the defective switch. Your video made this so simple, I can't imagine why we lived with a dark fridge for so long! I was ready to buy a whole new fridge, as repairmen are often nonexistent for small repairs. I am the biggest fan of your company & it's repair video. THANK YOU SO MUCH
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- larrie from punta gorda, FL
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
ice maker just stopped
part arrived on schedule,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- olin from forest city, NC
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker not working
First i shut the water valve off going to the fridge, I then removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires. Then i took the water line loose to the element, reverse the prosses and put all back on new element and installed,
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Victor from Fort Myers, FL
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
light in freezer section not working
Using plyers Pulled old switch down and out. Put new one in and pushed new switch up into position. The switch plugs into the contacts, no wiring needed. Worked like a charm. You saved me 200 dollars GE repair bill. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from West Seneca, NY
- Parts Used:
- WR9X502
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Frezzer would freeze up, refrigerator stayed cold, solved the problem. Now the refrigerator seems to be running more than usual.
Checked the defroster coil which is located behind the rear panel in the freezer compartment, it was still working. Followed the schematics down to the defrost timer, which is located in the lower front of the refrigerator and tried that. Plugged in the new part and the problem is solved.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tom from Dahlonega, GA
- Parts Used:
- WR57X10033
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
did not work, not sure what the problem is
water runs in now but still does not make cubes. just keeps dripping until I shut the water off.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from New Sweden, ME
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set
Ice maker not working
With help from this site, It was one of three things. I thought it might be what this site suggested the most common and it was. the valve in back of refrigerator at bottom. Water comming to it, but not getting past. Ordered part. Was here in a few days. Real easy to change out. A few screw / bolts and one wire that fit only one way. I did have to bend new bracket to make it fit. Now have lots of ice cubes!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- KIRK from Malibu, CA
- Parts Used:
- WR9X502
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Freezer work refierator compartment is warm
Defrost timer is hidden in the control panel in the refrigerator top middle. Turn to off and remove two screws which are hidden behind white tabs. I had to pry the old timer from the plug with a screw driver because it was tight. Try not to short across the terminals. Plug in the new timer. Replace it in the clip where you got old one and reinstall the controls. The freezer was still all frosted up so I had to remove the cover and defrost it with a hair dryer to get it to work. Then I turned it on and it works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- CURTIS from OCALA, FL
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Icemaker Froze Up/ Stopped Making Ice.
Your online instructions were easy to understand and follow. I replaced the outlet valve which took about 20 min. Then I had to dissasemble and remove icemaker to de-ice inlet tube and back wall of frezzer to defrost cooling fins. All to gether it took me about 1hr / 40 min. Frezzer now works just like new. Thanks for making it affordable and easy. Curt
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- theodore from salisbury, NC
- Parts Used:
- WR60X30349, WR60X114
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
bad fan motor
take fan out,put new in
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Huntington, NY
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Wrench (Adjustable)
Ice Maker Water inlet valve installed with the Refrigerator had a stripped threaded connection which leaked
Detached the old part from the refrigerator and disconnected the low voltage quick connect. Also disconnected the water line to the Ice Maker. Reinstalled the new part in the order it was disconnected and re attached the water line feed to the valve threaded connection. Turned water on and no problems.
Was this instruction helpful to you?
Thank you for voting!