GFE28GGKDBB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Karen from Salisbury, NC
- Parts Used:
- WR71X11045
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
I dropped The top left bin and it cracked
Popped it up and popped new one on
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- MICHAEL from MONMOUTH BEACH, NJ
- Parts Used:
- WR30X28682
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Socket set
Ice maker failure
Ordered a replacement ice maker. Simple to remove old unit one screw and one screw to remove wire cover to unplug. Replacement unit looked a little different as the left side of the new unit had various ridges which did not allow a proper fit into ice making box. After examining old unit and new I swapped the old left cover with new left cover and unit fit perfectly and it is working correctly. I suggest adding a quick note about the upgraded part as it may not fit properly and the side cover may have to swapped out.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from JACKSONVILLE, FL
- Parts Used:
- WR72X27635
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
left glide was broken
Left side was broken for about 8 years. Back of glide would fall down about every 4 months. This time the upper basket jammed up on the glide and the freezer drawer would not close. Had to break it to remove the upper basket.
From the time the parts were delivered and installed two Glide Supports, it took a total of 30 minutes. If that long. Before I ordered the part, I made sure I had the socket to fit the nut and that I was able to remove it. I removed the broken one after ordering.
PartSelect was the only website that I could find that carried the part.
From the time the parts were delivered and installed two Glide Supports, it took a total of 30 minutes. If that long. Before I ordered the part, I made sure I had the socket to fit the nut and that I was able to remove it. I removed the broken one after ordering.
PartSelect was the only website that I could find that carried the part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- elissa from ASHBY, MA
- Parts Used:
- RPWFE
- Difficulty Level:
- Very Easy
- Total Repair Time:
- More than 2 hours
Replaced thermistor 5.2 ohms of resistance
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kenneth from JUNEAU, WI
- Parts Used:
- WR55X44126
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
Door water and ice dispenser not working.
Replaced door circuit board. Vert simple to do. Problem was not solved! Replaced the main board with advice of ge tech. problem not solved. Currently waiting for the Tech to reappear. Not a happy person
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from Bartlesville, OK
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- QUOC-LOC from LYNN HAVEN, FL
- Parts Used:
- WR55X24064
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sara from White Plains, NY
- Parts Used:
- RPWFE
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
Water filter needed changing.
Snap filter into place while holding the filter slightly away from the refrig. When filter snaps into place, push it towards refrig into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Bel Air, MD
- Parts Used:
- WR55X24064
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Refrigerator and freezer drawer would not maintain set temperature
Condenser fan motor was running slow. This was not a problem included in your list of possible problems. I thought that maybe the capacitor was bad but have no way to check it. So I ordered one. when I received it, I installed it. That was not the problem. So I ordered a fan motor and installed it. That was not the problem. So finally I ordered a control board and installed it. That solved the problem. So maybe you should put "cond.fan motor runs slow" in your list of possible faults and what causes that problem. Capacitor was easy to install, simply remove the cover plate, flip off retaining wire, unplug the capacitor and replace. Fan motor was a bit more difficult. It must be removed from mount after fan scroll is removed. Remove one screw that holds scroll, bend the top down and remove. Then pull hard on fan blade to remove it. It must be installed on new motor. Two screws in frame mount can be removed with some effort if you have a 1/4" drive ratchet with a Phillips screwdriver bit. Then pull frame open and install new motor. Push fan blade on new motor shaft hard. Replacing control board was easy. I used a pair of long nose pliers with 90 degree bend to get mounting pins closed to pull board off.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Pasco, WA
- Parts Used:
- WR07X10131
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
compressor motor wouldn't start, so no refrigeration
My brother-in-law is a 15 year refrigeration technician who I called and described the problem to. He told me to put an "amp clamp" on the line side of the wires (black) that go to the starting controls on the side of the compressor. The motor has a label that has a number on it (LRA) that he used to determine the max amps it would pull. In this case, if the motor pulled 10 amps, then the motor was bad and I'd have to buy a new refrigerator. It was pulling less then 9 amps so he thought to buy a new overload, since the capacitor checked out (measured by multi-meter). As soon as the part came, I removed the back panel (4 screws removed by nut driver), removed the clip that holds the overload/capacitor assembly, detached the two wires from it, and removed the capacitor from the overload. I swapped in the new overload and repeated the above process in reverse. The only difficulty was that the new part was different in that the plug-in locations for the two wires were in different locations, and not marked. I had to disassemble the old part to figure out how it worked so I could deduce how the new one plugged in. Once that was solved, it was a quick fix. This was not a repair that just anyone could do; it required someone with a lot of experience to help me, and I am an engineer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- michael from silver bay, MN
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
Fridge Side Freezing/Too Cold
Followed the repair video, was spot on!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jason Mcgee from Catawissa, MO
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer would not defrost or maintain temperature
luckly i have a bit of experience in refrigeration im an hvac technician by trade. this repair was a bit tricky in that i did not know at first if it was a Temperature Sensor issue or the main control board. I had tested the defrost termination thermostat and the defrost heater and as i suspected they were ok. Next i wanted to test the thermistors (temp sensors) it is hard to find technical data on these fridges. I needed to test the thermistors resistance @ a certian temperature to ensure they were working properly but where do u get such data? I also wanted to know some information about the logic programmed into the board (i.e when do you initiate defrost etc. . .). I had no such luck so i figured since i tested the defrost heater and thermostat and they were ok and all of the evap fans and such were working i'd order a circuit board and new thermistors. Got the CORRECT PARTS from this site in 2 business days and my fridge is working great! changing the parts was really easy, figuring out which parts to change was the only difficult thing about this job.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michelle from Chimacum, WA
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
fridge to warm
followed part select video instructions
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chuck from TARRYTOWN, NY
- Parts Used:
- WR55X24064, WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
coils were icing up and refrigerator section was warm freezer was cold
Unplugged unit and removed vented cover over compressor section. The run capacitor is a simple fix 1 Phillips head screw and 2 spade wire connectors. For the temperature sensor I had to remove all drawers and the ice maker to remove the back cover to expose the condenser. Put a bowl at the drain stem in the rear of the unit and used a heat gun to defrost the coils on the condenser. Cut the wire about 3" from the sensor end . cut about the same off the new sensor stripped the wires put shrink wrap on each wire, attached butt connecors . heat gun for the shrink wrap and reassembled everything. Simple job that took about a half hour to do both. I will monitor the fridge for a couple of weeks to see if I need to change the control board.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brandon from Bruceton Mills, WV
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Socket set
Defroster stopped working and iced up evaporator coil
I have a GE Profile French door refrig. It's only about 4 yrs old and the defroster stopped working. I read the other repair stories and was able to narrow it down to either the temp sensor, defrost timer, or main board. The refrig section was up to about 47 degrees and freezer was around 25. I could tell it was trying to cool but couldn't. So I tried the temp sensor first. I cut and spliced the new sensor on the outlet of the Evap. Coil and it took about 15 mins. Turned refrig back on and waited. The coil started to ice over after about 5 hrs I left the back panel off so I could see if and when then heater kicked on. After about 8 hrs I looked in and saw a faint glow and water trickling down and running out the drain. Turned out the sensor was bad and wasn't telling the main board it needed to defrost. I would try the sensor if you are having the same issues before spending a lot of money on the main board, defrost heater and or timer.
Was this instruction helpful to you?
Thank you for voting!