Models > GSE25ESHCSS > Instructions

GSE25ESHCSS General Electric Refrigerator - Instructions

Jump to:

All Instructions for the GSE25ESHCSS
46 - 60 of 1422
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Larry from Georgetown, TX
Parts Used:
WR29X43990, WR17X11497
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Pieces broke off Auger and Cover cracked.
Remove and empty ice maker from freezer . Remove two screws from bottom to remove the front panel (cover bucket). Remove one screw which holds the deflector on top of the bucket.(tray which holds the ice curbs). Remove one screw that holds the clip that holds the wire actuator rod.

To remove the the ice crusher/dispenser mechanism from the bucket I used two table knives Spread one side of the bucket with one knofe and pry up with the other to get the retainer wedge free from the bucket side. Repeat on the other side. Once the retainer wedges are free the ice crusher/dispenser with the auger attached can be lifted free from the bucket.

With a spanner wrench remove the nylon nut from the shaft. NOTE: THIS IS A LEFT HAND NUT. Note the orientation and relationship of the crusher blades. They must be replaced properly for the system to crush ice and dispense cubes correctly. Remove blades and spacers from Auger.

Reassemble in reverse order. Be sure to get the actuator rod in place in the cam for the dispensor cover before sliding the crusher/dispenser mechanism totally in place. If not in the cam correctly the crusher/dispenser may have to be removed again.

Although a little difficult the first time the project is easily done by an adventourous handy person.
40 of 55 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Brentwood, TN
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
FERNANDO from MIAMI, FL
Parts Used:
WR51X10055
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Refrigerator Not Cooling due to ice buildup on coils
Removed shelves from freezer section and removed protective cover using a screwdriver and nutdriver. 5 screws.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instructions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
35 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Edgartown, MA
Parts Used:
WR17X22070
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Water if refigerator door is really slow. Ice making is really slow.
Used by pass filter and problem disappeared. Of course wayer is now unfiltered. This is a GE design flaw. Also replacement filters are outrageously expensive and do not last long. We have good water here and I'll stick with the bypass.
41 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from Cave Creek, AZ
Parts Used:
WR30X10093
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
41 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Milton, FL
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
32 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Victor from Houston, TX
Parts Used:
WR62X10055, WR17X11653, WR17X10706, WR02X10585
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The compartment behind control panel with snow
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.

I recomend these parts be replaced once time for each two years.
40 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Lodi, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
33 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
joe from raleigh, NC
Parts Used:
WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice despenser door would stick open and frost up to the point of of ice not coming out
after finding the video describing the same problem, i gave it a shot. Major problem was figuring out how to take outside trim off of the ice/water dispenser. Everything i tried did not work like the videos i had seen. Looking thru some of the posted blogs i found another way to get behind the control panel without even taking off the trim piece. i pressed a 1/8th allen wrench into the two outer holes on the bottom of the control panel which released the panel to pull out from the bottom. after that it was simple to release the three plugs from the circuit board and remove the control panel. 4 phi lips screws later the ice chute comes straight out revealing the flapper door which is held in by 2 more screws. once that assembly is out the solenoid is held by three more screws. there was nothing difficult at all about this repair once the secret was out about the first step about the three holes (use only the outer two) in the bottom of the control panel
35 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Suffolk, VA
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
30 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Clermont, FL
Parts Used:
WR29X43990
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Auger blade parts showed up in my iced tea
Dis-assembly only consisted of three screws, but for the not-so mechanically inclined, I would suggest taking a picture of the ice crusher blades before removing them from the auger shaft.
29 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Mason, OH
Parts Used:
WR23X10783
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Water dispensor would not shut off
Actually this was a two part repair of which I purchased both parts. The micro switch Pt # PS296176 and also a double outlet water valve Pt # PS304374 from Parts Select as well.

The difficult part was accessing the area to get to the micro switch.

The trim had to be removed, then the cover.

Then one unplugs the board and removed the face plate which also contains the micro switch.

Once removed the two electrical terminals had to be disconnected, the micro switch installed and terminal reconnected.

Then reverse the removal procedure.

Then on to the double outlet replacement.

Suggest watching the installation video for the replacement although it was really a straight forward repair.

Two things to remember.

1. Unplug the fridge

2. Shut off the water to the dispenser

Overall it was not bad at all.

This was my first attempt at refrigerator repair and it went well.

Good luck on yours.

John
32 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
MARYT from KISSIMMEE, FL
Parts Used:
WR72X242, WR72X240
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
the cheap plastic drawer holders broke!
Not only were the parts delivered in 2 days....but a phillips head screw driver and matching up the new rails with the old ones turned out to be a super easy and fast repair!! A monkey could do this repair!! But now I noticed the left hand top drawer rail is cracked! It stinks that the quality of the original parts are so poor...but at least I'm saving some money doing it myself!!!
31 of 44 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Tacoma, WA
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
water running slow
unscrewed old filter by hand, installed new filter.
35 of 57 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William M from Ft Myers, FL
Parts Used:
WR62X10055, WR01X37886
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Solenoid had become rusted/crank door wouldn't close
First, had to use punch tool to pop out electronic face panel. Face unit still connnect via wires. Use painters tape to hold against refrig. Next, Remove ice/water dispenser and also tape to door. This will give you access to solenoid. Remove the 3 screws holding it in place and unplug fsolenoid from Face Panel. Screw new solenoid and place and connnect to Panel. Goood idea is to unplug regrig. while doing this and put a little WD-30 on shaft of solenoid. May want to order new screws, could be rusty, that hold solenoid in place. Sounds a bit complicated but not that bad a job. You'll save over$100 over GE's service.
30 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GSE25ESHCSS
46 - 60 of 1422