Customer:
michele from North Smithfield, RI
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
my refigerator was warm but the freezer was cold and working correcttly
I went to a GE repair center to explain my problem, the service center reccomended that I have a techinician come out o look at it. $75.00 for the visit and what ever labor and materials wuld cost.

I went on line to see if there were others having this same problem and found that there were many with the same problem.

After reading some of the ways that people found out what was wrong ...it became a matter of three components, the timer, heater or thermostat.

I tried the most common component and the less expensive one first , the thermostat switch I installed it very easily snipping two wires and attaching the news using wire nuts I used the diagram on this website to pinpoint the component and there has not been a problem since.
272 of 342 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alfred from Novato, CA
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Replace water filter
Unscrew old filter and remove(counterclockwise). Line up arrow on new filter with arrow on connection housing. Turn clockwise till resistance met. Do not overtighten. Follow directions. Simple.
224 of 338 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Menomonie, WI
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
refrigerator was getting too cold
I removed the old temperature sensor by cutting the wires. I attached the wires of the new sensor with wire nuts and mounted it in the same bracket.
143 of 199 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jonathan from Lilburn, GA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Sticking Light Switch
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the catch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.
116 of 144 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
DOUG from MARYSVILLE, OH
Parts Used:
WR60X10185
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Evaporator motor sounded like wind in the trees howling
I had to remove all of the shelves.....part of the ice maker.....the rear cover over the freezer coils.....There were two wires that came from the back of the freezer that were also incorporated with the fan motor plug from the factory....This caused me to cut all of the wires from the new motor and soider them to the existing plug and shrink wrap the connections. If GE would have supplied two new ends I could have cut only those wires added the ends and inserted them into the new motor plug thus eliminating an extra hour and a soildering iron,,,,In my case not a big deal however not a project for those who have trouble with repairs using these type of tools.
111 of 137 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Romeo, MI
Parts Used:
WR60X10185
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
The evaporator fan motor stopped running, freezer was warmer than normal
First ,I placed all the frozen food from the freezer into the lower fridge compartment. Removed the main shelf. Removed the ice cube tray shelf. Removed the center plastic covers using a nut driver. Removed the complete inside back wall of the freezer to get access to the fan. Simply removed about 5 screws, and cut 3 tie straps that held the wiring in place. Unplugged the fan connector and removed fan with its brackets and placed them on the kitchen table. Then used the nut driver to remove 2 screws which hald the fan to its bracket. Simply pulled off the fan blades and pressed them onto the new motor. Mounted new motor onto the bracket. Reinstalled the fan assembly back into freezer. Reconnected the wiring and the fan began to run... BE CAREFUL NOT TO TOUCH THE FAN WITH YOUR FINGERS!
Finally replaced all the covers, panels, and shelf etc. and everything is once again nice and cold.
65 of 87 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Gainesville, VA
Parts Used:
WR60X30922, WR60X10185
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fan motor making noise due to broken fan blade
1) Unplugged fridge and removed cover over light in freezer.
2)Removed screws holding cover over motor.
3) Removed screws on bracket holding motor in place.
4) Un plugged motor and used razor blade to cut grommet holding wires in place.
5) Plugged in new motor and routed wires through grommet. Then used zip ties to hold grommet together.
5) Re-attached motor bracket and installed new fan.
6) Reinstalled cover over motor.
64 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Murfreesboro, TN
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
fridge side freezes some items
went to your website and viewed exploded view to find the sensor( there are two I just picked one to replace for now), pried the cover off carfully and pulled out the sensor. I snipped the wire in the middle leaving plenty to work with. I shortened the wire on the new piece, spliced the wires together and with some 3M rubberized, tape wrapped them up, replaced the sensor back into the cover and snapped in place.
54 of 75 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Mancos, CO
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
freezer cold / fridge warm
put fridge into test mode, failed One sensor. Took it out, Tested it, Ordered part also picked up splice kit from electric store spliced it truned on and good to go
46 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Madison, CT
Parts Used:
WR60X10185
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
The freezer was whining and growling like a baby
I replaced the motor that runs the fan in the freezer compartment. Had to remove a number of shields to get to the fan and then some wires and screws to get at the motor. It came with a plug with 4 wires in it and I was supposed to pull 2 wires out of the old plug and place them in the new plug. Long story short the pins would not extract from the plug and the wiring harness was molded in solid plastic, so I ended up cutting the 4 wires to the motor and splicing in the new one and taping them with electrical tape. So far no more moaning and the ice cream is still hard, so I think we nailed it.
43 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from Edgartown, MA
Parts Used:
WR17X22070
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Water if refigerator door is really slow. Ice making is really slow.
Used by pass filter and problem disappeared. Of course wayer is now unfiltered. This is a GE design flaw. Also replacement filters are outrageously expensive and do not last long. We have good water here and I'll stick with the bypass.
41 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Milton, FL
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
32 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Suffolk, VA
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
30 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Tacoma, WA
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
water running slow
unscrewed old filter by hand, installed new filter.
35 of 57 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from College Station, TX
Parts Used:
WR60X10185, WR02X10668
Difficulty Level:
Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Freezer and fresh food compartments too warm
After having replaced the main control board and three thermistors, the fridge was still having difficulting getting cold enough - it wouldn't get colder than 15F / 42 F. Uniform frost on the evaporator coil ruled out a sealed system leak, so the remaining culprits were the either the evaporator fan motor or the compressor.

I read that a failed control board is almost always the fault of a bad evaporator fan motor, so this item was the most likely suspect.

To get to the evaporator fan motor, I had to remove, in this order:

1) Icemaker
2) Auger motor and brackets
3) Icemaker bracket
4) Freezer lights and bulb sockets
5) Evaporator panel
6) Evaporator plenum cover
7) Evaporator fan motor bracket

The greatest difficulty lay in swapping the new fan motor harness. Two pins in the harness connector were used for the evaporator thermistor.

I had to carefully cut through the old connector (using a Dremel) to extract the crimped-on pins for the thermistor, then reuse them on the new connector.

The fridge is now maintaining -5 F / 35 F in the freezer / fresh food sections.
25 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!