CNS23SSHAFSS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Harry from DURYEA, PA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paul from ENDICOTT, NY
- Parts Used:
- WR55X24064
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
freezer stoped freezing
my freezer quit freezing, it would freeze for one day, thaw the next, so I went online, found PARTS SELECT, LOOKED UP MY MODEL #, come to find out it needed three parts to keep my freezer to freeze, first part was a thermistor a small PART took me longer to remove all the covers, and shelving, PULLED THE OLD OUT, CUT THE WIERS TO SIZE, AND REINSTALLED, IT WELL! THAT WASN'T ENOUGH THE FREEZER STILL DIDN'T FREEZE IT THOUT IT WAS A COOL WORMING OVEN, HAD TO INSTALL THE THERMISTOR I, SO I DID, TEN MIN, NOW I THOUGHT THAT WAS IT BECAUSE IT STAYED FROZEN FOR A WEAK, HAVE YOU EVER EATEN SOUPY ICE CREAM? SO BACK TO PARTS SELECT, THIS TIME I BOUGHT ONE MORE PT, THE RUN CAPACITOR, FIVE MIN, THAT/S ALL IT TOOK TO INSTALL. I DID NOT KNOW AT THE TIME YOU NEED THE THREE OF THEM TO RUN THE FREEZER ONE TO KEEP THE TEMP., ONE TO KEEP THE FAN RUNNING THE WAY IT SHOULD, AND THE THIRD TO MAKE SURE THE OTHER TWO KEEP RUNNING. NOW I CAN SET IT AT 4- 5 AND. FREEZE.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Douglas from LAFAYETTE, LA
- Parts Used:
- WR02X11331
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Squeky Evaporator Fan
I made my wife fix it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mary from WESTON, CT
- Parts Used:
- WR30X10093
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker stopped working
Installation could not have been easier!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Hugh from LADSON, SC
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ice Maker stopped making ice.
Did the repair just as the instruction said, once I read it. The part I didn't read was that if the plug was under the ice maker, you had to take the wire out of the clip on the side. So, had to dismount ice maker, unclip wire, remount maker, plug it in. Still under 30 minutes. Thank you.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frank from VERO BEACH, FL
- Parts Used:
- WR55X24064
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
The Refridgerator and Freezer were not cooling.
Installing the part repaired the fridge and freezer immediately.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Wyckoff, NJ
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker stopped making ice
I had made a dry run at the repair after watching the instructional film provided by part select and it seemed easy enough.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
The only problem was that i needed to use the electrical cord extender (provided) to adapt to my plug type. That presented a problm because it needed to be tucked up out of the way to allow the ice bin to clear. Just needed to be creative in how you wrapped the cord behind the ice maker unit before snugging the attachment screws.
Cranking out ice like crazy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from ROSEMOUNT, MN
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fred from LA QUINTA, CA
- Parts Used:
- WR17X22070
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Replace water filter with bypass plug - filter is redundant with home osmosis system
If you have a reverse osmosis system for filtered water system in your home that also feeds the refrigerator, using another water filter in the refrigerator is redundant, so GE makes a Water filter Bypass Cap that allows you to run using the already filtered water without needing to expensive water filter. FIRST - using a phillips screw driver remove the toe kick plate at the bottom front of the refrigerator - two screws - one on each side of the plate that extends the entire width of the refrigerator. SECOND - Locate the water line (should be right in front) and the valve to turn off the water. Turn valve clockwise (right) until completely closed. Then test by attempting to fill a glass with water using the dispenser on the door. If any water continues to come out, continue turning the valve (without forcing it) clockwise until it has been turned as much as possible. If water still comes from dispenser, locate the source of the water line - most likely from under the kitchen sink. There should be another valve under the sink, or simply turn off (turn the cold water valve clockwise) until water cold water completely turned off. Test again as required. THIRD - clear the top right hand back shelf directly under the water filter screwed into the ceiling of the refrigerator in the rear top right side of the refrigerator. Place a small towel under the water filter, and slowly turn the filter 1/4 turn clockwise without using force. Continue turning until the full 1/4 turn is complete and the filter will drop down without pulling. Place the old filter upside down in the sink, thereby allowing the filter to drain any water present in the filter. FOURTH - remove the filter plug from package, notice notches in top of plug that align with gaps in the area where a filter would typically be screwed into the filter location in the ceiling above the top right shelf in the refrigerator. After aligning notches in the bypass plug with gaps in the screw mechanism, carefully turn the bypass plug 1/4 turn counter- clockwise - at which time the bypass plug should be firmly installed. FIFTH - Reverse step SECOND, and turn valve Counter-Clockwise until valve is completely open. Test to ensure no water is leaking from the Bypass Plug. SIXTH - Finally reverse step FIRST by reattaching the toe kick plate using the two phillips screws removed in Step FIRST. NOTE: The Bypass Plug is quite inexpensive, but after adding shipping from Canada - the cost is about the same as purchasing a new filter for the refrigerator. :-(
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paypal_shipping_address from Ripon, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Myrtle Beach, SC
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Yearly replacement of filter
Moved stuff out of my way on the top shelf, reached in and turned old filter to remove. Filled new filter with water, lined up and turned to lock in place. Whew, never thought I would get that job done. :-)
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Roscoe G from ROCHESTER, NY
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Anaheim, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
The icemaker quit making ice and the water started forming on the bottom of the ice bucket.
First I removed the electrical plug from the back of the freezer that plugs into the icemaker. I then removed the two hex head screws that hold the icemaker to the wall of the freezer and removed the icemaker. I removed the plastic cover, which incidentally protects the gears, by prying it off with a srewdriver. I removed three small nuts(7mm) which holds the internal cam in place. I removed the cam by pulling it off the shaft. Once I got the part from you folks I reversed the procedure that I just mentioned, and put the icemaker back together. It works great. The part with shipping was around $16.00. A new icemaker was roughly $159.00. If I would have called a technician it would have cost around $300.00 to repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Stewartsville, NJ
- Parts Used:
- WR57X33326, WR02X11330
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Wrench set
water leak from water line and value housing
Unplugged unit. Removed back cover plate. Used 5/16 water line. Cut old broken line. Used water tube union and attached new line. Removed electrical contacts. Note very easy removeand replace the red and white hookups. Next remove water line at the old vale with1/2 wrench. Hook up water line to new valve. Icemaker line was not damaged so I removed from old valve and trimmed the end. Really installed line to valve. Plugged in fridge and turned water supply back on. Check for leaks. Had trouble locatingthe 5/16 water line but found bulk. PARTS SELECT had the guest connector and the replacement valve. I received the correct parts and saved me $$$$. Plus my wife happy right before the holidays! !!,
Was this instruction helpful to you?
Thank you for voting!