Myrna from Wyalusing, PA
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
the cams on bottom of door wore out with age- 20 years
Replaced the old cams with new ones, door works perfect now.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Portland, OR
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Door closing cams were both broken
Remove screw at hinge cover, top of door.
Remove two screw/nuts at hinge and remove hinge while holding door in place.
Lift door off of lower hinge
remove two nut/screws at bottom of door and replace closing cam. Be sure the pivot pin hole in the cam is lined up with the hole in door.

Next drill out rivet holding cam to lower hinge on the refer. Install cam with a pan head screw and nut (to replace rivet). It will help if you remove the plastic grille cover at the bottom of the frige.

Set door back on the lower pin and shut so the the magnetic strip holds the door in place. Re-install the upper hinge loosely. Adjust the door for an even gap and tighten the screw/nuts. Re-install the cover.

A very easy fix.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Shirley from Toccoa, GA
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
Cam wore out and the door would drop down. To close the door I had to lift it up and close it.
First of all, It was Christmas and no extra money to pay a repairman.
i got on the computer and started looking for a parts breakdown for an older GE side by side.
I finally found it and located the part I thought we needed.
I looked at several parts dealers and yours had the best price.
anyway it arrived in just 2 days. My son helped me remove the door and we put the new part on and I just saved the cost of a service call.

Thank You
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Pradip from Maperville, IL
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
doors were not aligned in height so door was not closing proper and lossing lots of cold air from refrigerator
Door needed to be supported before hinge assembly was removed. After replacing broken cam doors aligned and doors closing properly.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
gregory from ellerslie, MD
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
door was uneven and wouldn't close tight
removed the door, installed the cam riser, and reattached the door. It took longer to remove the contents in the door than it did to install the cam riser.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Grand Blanc, MI
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Door closing cam worn out
Removed refrigerator door and replaced bottom door pivot with the included mating cam and the door closing cam on the bottom of the door.

I didn't know that there were two mating cams and only ordered the door closing cam which I read online was the problem. It was the number one part on the part select list. The number two part was a kit including the door closing cam and the pivot with mating cam attached. It would have been helpful if there had been some notes that said check condition of both cams before ordering the part. So I have a spare door closing cam and paid an extra $19 including $8 shipping which negated a return.

The repair is easy - getting the right parts the first time is the trick.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robin from North Plainfield, NJ
Parts Used:
WR2X4901
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Door Cam And Cam On Refridgerator Were Damaged
I did not realize I needed 2 cams to complete repair. Door cam was riveted in. I had to drill out rivet and replace with nut and bolt. Otherwise it went quite sommothly. At first I just replaced the cam on bottom of refridgerator but door was not quite right when closing. Further inspection showed the door had the other half of cam that also needed replacement. Needed 2 orders. Paid for 2 shippings.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
david from pocatello, ID
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
plastic cams on the door broke so the door wouldn't close
Why don't they just tell you that you have to buy 2 cams. I have now replaced the cams on both doors. The other door broke about 4 years ago. Fortunately the first time I read the user commetns or I would've bought just one. It is a quick easy fix. The longest step is drilling out and replacing the rivet. Everything else is done with a nut driver.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Burmingham, AL
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Problem closing door, would not shut easily.
My wife and I gave an old, but really good refergerator to our son (a Major in the Army). Upon taking it into his house he had to remove the doors of the refergerator. While he put the doors he lost the "cam" for the door, making if difficult to close (actually had to lift the door up and then close it). I ordered the replacement part, and unless I am mistaken, it arrived the same day. I still cannot figure out how this happened, but it was great!!
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
vincent from mahwah, NJ
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
door was not closing properly
Your vidio was Brilliant !!i just followed your instructions
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Upper Malboro, MD
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
Door would not shut by itself.
I followed the directions on the computer and everything went just as the video said it would. This was one of the easiest repairs I have ever done. Usually, it does not go as planned.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Manuel from Winnetka, CA
Parts Used:
WR17X4312
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
I do not have an Ice Bucket.
I neeeded an ice bucket for a refrigerator that was given to me. I wish if I could have oder the whole part as a whole.So, this is what I did. I order the Auger and Ice Bucket Assembly.Later, I realize when I received the part that I also needed the Cover bucket assembly and the Ice storage door.Now I do not know if when I get the rest of the parts if it also comes with the screws that hold the cover bucket on or if I have to order the screws separate.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles M from Concord, NC
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Wrench (Adjustable)
Door Closing Cam broke
The bottom of the door was 5 " off the floor. A 2x4 block and a 4x4 block were pushed under the door and supported it while the water line was disconnected the hinge removed and the cam replaced. It was a simple fix and reading other people's experience made the repair so much easier.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Arrroyo Grande, CA
Parts Used:
WR30X256
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Hole in bottom of ice bucket
Transferred ice supply to another freezer. Removed ice maker unit from freezer and studied assembly. Removed the 5 screws holding the bucket in place while keeping track of which screw went where. The only positional component to remember was the motor control pivot retainer. Wiggled and fiddled to remove the old bucket. Wiggled and fiddled to put the new bucket in place. Replaced the 5 screws, dumped the reserved ice back into the bucket, and returned the ice maker unit to the freezer.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chad from Wichita, KS
Parts Used:
WR17X4312
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Ice bin rusty and replaced thermostat and defrost timer
the ice bin was a cinch with the complete part ordered from Partselect.com. Just had to replace the old faceplate onto the new part put the ice bin back in the freezer and voila. Didn't really need to replace the thermostat but did anyway with the defrost timer and then the thing started keeping temperature again. Thanks a bunch! I just hope the refrig will hold up a few years longer!
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TFX24EJB