Models > ZIS360NRG > Instructions

ZIS360NRG General Electric Refrigerator - Instructions

Jump to:

All Instructions for the ZIS360NRG
91 - 105 of 442
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Theodore from Carteret, NJ
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Water Leak behind Refrigerator
Shut water behind the refrigerator, unplugged the unit. Unscrewed the back tin panel and simply unscrewed the brace scew for the Double Outlet Water Valve. Disconnected the hoss - inspected the hosed for wear. Next detached the hoses and power source to the unit... reconnected both hoses & power source, plug the refrigator back in and inspected for any water leaks. Simple!
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Royce from Pasadena, TX
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Nothing to tell it was a replacement
Nothing to tell it was just a replacement part that the old part was removed and the new one inserted. Works like a dream Thanks
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marie from Philidelphia, PA
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
replace filter
just had to unscrew old one put the new one in
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Coto de Caza, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Interior Light did not go on due to faulty switch
I ordered two switches, replaced both with a knife in 10 minutes. Interior light works, thanks.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Katherine from Converse, TX
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
Was very helpful to have a video giving you instructions
Of course being a women to say I repair my refrigirator is very self gratifying specially when share with other womens like me divorce,having to do on their own, great site, very simple explain on the video with words I could understand, no surprices right to the penny. I save a lot of money, thank you so much, i recomend the site to anybody.
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from WATERLOO, NY
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set, Wrench set
Ice maker working but water dispenser not working
The very first symptom here is important! The door water dispenser is not working but the ice macine is working. You may only have a frozen water tube in the door so do the following before diagnosing that your solenoid valve is bad: 1) the tube usually runs under the front of the refrigerator and usually has a quick disconnect. Undo the connection and press the dispenser. If water comes out of the tube you have a frozen or blocked tube in the door. 2) Immediately adjust the temperature in the freezer and warm the freezer compartment as much as you can without destroying the freezer contents. Wait 24 hours. This will usually unfreeze the line. Do not waste your time with a hair dryer. NOW, if this doesn't work and you are convinced you need to order and replace the solenoid, follow these steps. Assemble your tools first. I needed a good ratchet set and a screwdriver. A shop towel is helpful for spilled water. A light is handy. Pull out the refrigerator to gain access to the rear of the unit. Unplug the power and close the water valve (older homes, you may need to actually shut the house water supply). Remove the screws which hold the cover over the lower half of the refrigerator. On the left you will see the solenoid. It's always good to see that your new part matches the one you feel needs replaced. They may not match perfectly due to changing design but they should be very similar. One screw holds this part in place and access is very simple. Now simply unplug the electrical connections. In my case, one blue "blade" type connection (powering the water) and one red "blade" type connection powering the ice maker. They are not the same size and this coupled with the coloring means you will not accidently switch them. pull the tubes clear of the solenoid. This is simple and needs no explanation. Grab your new solenoid and reattach both the electrical and water lines (two, remember, ice maker and drink dispencer). Replace the single screw. Re-attach the rear, lower refrigerator cover and go to the front of the unit to check the water. You can listen carefully and hear the power engage from the new part bringing you water. Clean up, replace the refrigerator back to its place and look really tired when your wife sees that you worked "so hard"! You probably saved at least $50-$80 from a service call.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from PLYMOUTH, MA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Ice maker needed replacement
Unplug refridge then loosened two bolts holding old ice maker. Lower then unplug and removed. Plugged in new harness and tightened two bolts to secure new ice maker. Plug in frig and wait for ice.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from SCOTTSDALE, AZ
Parts Used:
WR55X10025
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lynn from MOUNTAIN HOME, ID
Parts Used:
WR30X10093
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Made ice would not eject from ice holder bin
removed broken bin , slid new ice bin in closed door. I bought the complete part.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
clyde from RIALTO, CA
Parts Used:
WR60X24484, WR60X10209
Difficulty Level:
Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from ORO VALLEY, AZ
Parts Used:
WR49X10283
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Socket set
Compressor would not kick on and condenser fan ran constantly
Remove back panel on bottom of fridge to access compressor area. Remove screws from water solenoid and water valve and push to the side so the side of the compressor can be accessed. Then locate the inverter box. You will find a Phillips head screw on the bottom of the inverter. This is the only screw that hold the inverter in place. Remove the screw and tilt the inverter box forward away from the compressor, then lift the box out of the the holder. You may have to wiggle it a bit to get it out. Remove the plug that attaches to the compressor and then with the power on check your voltage coming to the compressor. It should read 120 volt. If it doesn’t your inverter is bad. Remove the other plug on the inverter box and pull the box out.
Reinstall the unit in reverse order. Use the appropriate jumper to plug into the wire connection going to box and then plug it into the connection off the fridge.
Once everything is reinstalled and before you put the back panel on plug your refrigerator back in and you should be able to hear the compressor working or feel the top of it to make sure. If it’s working you are good and can reinstall the back panel.
It will take 4-5 hours to come back to temp if it’s been off for any length of time.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
ROBERT from OCALA, FL
Parts Used:
WR49X10283
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Wrench set
Not Cooling
-Pulled refrigerator out to access back.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
-Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mike from Aguilar, CO
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Karen from SAN ANTONIO, TX
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker filled too full and ice froze in the basket and a piece was broke on the icemaker itself.f
My son did it , and showed me what he did when he was finished.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerda from RIO RANCHO, NM
Parts Used:
WR57X33326
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Wrench (Adjustable)
water was dripping in freezer (ice maker)
We actually followed the instructions of the video for the installation of the dual inlet valve and it was incredibly easy to perform. The fridge works perfect again!
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ZIS360NRG
91 - 105 of 442