Models > MSX25DPBAAA > Instructions

MSX25DPBAAA General Electric Refrigerator - Instructions

Jump to:

All Instructions for the MSX25DPBAAA
91 - 105 of 248
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
George V. from PITTSBURGH, PA
Parts Used:
WR17X3489
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Freezer Light Shield Cracked at mid fastening point
replaced the broken one with the new part
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from PARKVILLE, MO
Parts Used:
WR02X10098
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Had a 'ticking' sound
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side of the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from SUN VALLEY, CA
Parts Used:
WR17X2061
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Original part cracked allowing crushing fingers to grab plastic guide jamming it.
Part attaches to metal plate near crushing fingers which attaches to ice holding bin. Remove about 6 screws total on each side of plate. You must disassemble the auger & other parts so you can reassemble it in the proper order. Not many parts but i always take pics to cut down on time. New part is at the other end of the auger and acts as the holde of the auger shaft. Picture a crankshaft with a bearing on each end so the auger rotates between new part and the other end of auger shaft. That's it.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Wendell Hayes from Dillob, SC
Parts Used:
WR60X187
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Fridge wasn't cooling and half freezing
Part was perfect fit .Removed fan .three screws.replaced that s it
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Walter from SANDIA PARK, NM
Parts Used:
WR17X3670
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
On the water dispenser line, the heat from the compressor unit had cracked the feed line, resulting in a leak.
I removed the plate covering the water valve for the ice maker and water dispenser, removed the nut holding the 5/16" tubing to the valve and took off the tubing and nut. I did not need to turn off the water supply or unplug the unit. I removed the kick panel in the bottom front of the refrigerator, replaced the existing plastic fitting with a new push-on fitting, then spliced the tubing coming from the water chiller to the valve where the leak was thus bypassing the broken tubing with new tubing. I reassembled the valve using the original plastic compression nut, replaced the cover and ran the water dispenser while checking for leaks. The water dispanser works great with no leaks.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Louis from LEAGUE CITY, TX
Parts Used:
40A15
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Change bulb
Easy
3 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Phil from MADISON, WI
Parts Used:
WR30X256
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Broken plastic on ice hopper that helped stabilize the auger
Emptied hopper
Removed screws to remove auger from existing
This was so easy I impressed my wife
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JACOB from COLLEGEVILLE, PA
Parts Used:
WR62X23154
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Only crushed ice. No cubed.
Found a step by step video on YouTube made replacement very easy. Cubed ice is back. Time for a cocktail to celebrate!
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Al from River Edge, NJ
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice maker discharge was slow and jammed with ice and frost. The cause was a distorted flapper that did not seal properly, admitting warm air into the dispenser chamber.
Excellent video was available on the Parts Select website. It was simple. The selector panel pulled out by hand from the bottom. The subpanel was removed with the four screws. The flapper snapped out of the holder with two clips. The new one was inserted in reverse order.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
joselito from riverview, FL
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice Building Up In The Ice Dispenser Chute
Under the control panel there are three small holes. Insert ballpen or small flat screw driver on both outer holes to push a tab lock that holds the control panel in place. Then pull out control panel and three set of wires will be exposed and disconnect wire connectors (connectors have different sizes so you wont get confused in reconnecting). Unscrew four screws on each corner that holds the ice dispenser assembly (a part where you push your glass against to dispense ice or water. The flapper is exposed and easy to replace.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ken from Wesley Chapel, FL
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
froze in freezer
unclipped and replace with new part.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hillary from MONTCLAIR, NJ
Parts Used:
WR02X11330
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Leaking from connector every time water was used
I watched the instructional video on this website and did everything that it said. There is no more leak when I use the in door water. Was as easy as it looks in the video and I am very happy!
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GARY from LIVONIA, MI
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice Maker Clogging up from frost build-up
Turn off power
Remove operator faceplate by pullling out on outer lower corners
Disconnect wire connectors from circuit board
Remove four screws from dispenser and pull out dispenser assy
Replcae Door ASsembly
Put everything back in place
Power up
Job Done
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
EDWARD from DALZELL, SC
Parts Used:
WR57X10012
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
leaking dual inlet valve
remove and replace valve, by removing access panel in back of refrigerator. loosing inlet and outlet water lines,and remove one screw holding valve. very easy. installed valve in reverse order.
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Castlewood, VA
Parts Used:
WR02X11330, WR17X2891
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Wrench (Adjustable)
Water tubing lines runs very close the compressor. Over time the heat caused the line to become brittle. Result was broken line and lots of water under the unit.
Cut the line inside the regiferator behind the bin and used the tube union to attach new 5/16" tubing to run to the solenoid valve assy in the back of the refigerator. Location of the valve assy makes connecting very difficult. But was able to complete repairs.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the MSX25DPBAAA
91 - 105 of 248