MTX17KABNRWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- denis from freedom, NH
- Parts Used:
- WR60X203
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
was not defrosting
first i removed all the screws inside the freezer compartment took out theback and bottom to get to the evap motor,unpluged the wires and removed the evap motor ,removed the fan from old unit and put it on the new unit them mounted it to the back wall of the fridge,,, and put back top and bottom
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mackenzie from Williston, ND
- Parts Used:
- WR09X20002
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Compressor would randomly not turn on. Fridge too warm sometimes.
Replace temperature control. That fixed it. Also, removed plastic bag obstructing air vent in freezer which added performance. Fridge works good now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Boyd from Blaine, WA
- Parts Used:
- WR09X20002
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Could not adjust temperature
Replaced temp controller
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Fred from FLUSHING, NY
- Parts Used:
- WR60X10168
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
The freezer just cool but could not freeze the water and the front of door is quite hot to touch.
First I observe that the compressor motor is running since the freezer is cooling. The purchase of the condenser fan is initiated and when the part arrive it is just easy to reinstall the replacement condenser fan.
The problem on the front of the freezer door remains hot to touch and the compressor runs for a while and stop. The freezer is cold but still could not freeze the water. Inspection of the condenser fan reveals that it is not running. The order for the condenser fan from PARTSELECT came in a few days. Cleaning of the condenser of lint was first done and the process of removing the defective fan is just easy so with the installation.
The refrigerator as of now is running in perfect condition!
The problem on the front of the freezer door remains hot to touch and the compressor runs for a while and stop. The freezer is cold but still could not freeze the water. Inspection of the condenser fan reveals that it is not running. The order for the condenser fan from PARTSELECT came in a few days. Cleaning of the condenser of lint was first done and the process of removing the defective fan is just easy so with the installation.
The refrigerator as of now is running in perfect condition!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jose A from WEST PALM BCH, FL
- Parts Used:
- WR09X20002
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Was getting too cold
Was only two screws after that carefully took the part away unplugging the wires at the same time was plugging in to the new part and was done after 5 or 7 min
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Herbert from POCONO LAKE, PA
- Parts Used:
- WR60X10168, WR02X10098
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
the condenser fan motor was intermittently verynoisy. obvious sign of a (possibly imminent) failure
1 unplug the appliance
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor
2. remove the rear cardboard cover, giving access to the compressor and condenser area
3. remove the two (condenser motor bracket) mounting screws, then with the motor assembly in your hand remove the the fan blade which is friction mounted to the motor shaft( note the exact position of the fan blade on the motor shaft so you can replace it in the same position when you reassemble), remove the two wires connected to the motor. Also remove the rubber resilient mounting grommets on the motor mount frame as these can harden with age and cause excessive vibration.
4 install the new motor into the mounting frame with the new grommets
5 reconnect the two wires to the new motor (non polarized)
6 secure the mounting frame (with the installed new motor) back in place
7 slide the fan blade onto the new motor shaft
8 screw the rear access panel back in place
plug in the refrigerator. the next time the compressor and condenser fan cycle on, verify operation of the new condenser fan motor
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from PARKVILLE, MO
- Parts Used:
- WR02X10098
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Socket set
Had a 'ticking' sound
Separately (from a different site) purchased new compressor fan and motor. I purchased the grommets here because the other site listed the grommets as temporarily out of stock. I did watch one of the videos on PartSelect about the grommet replacement. Repair was pretty simple, biggest challenge was getting to the screw on the far side of the motor. Removed the two screws holding the fan motor into place. Removed motor and blade. Reinstalled with new fan blade, new grommet and new motor.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- paula from KEY BISCAYNE, FL
- Parts Used:
- WR51X444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Wrench set
Defrost Heater too old
I disconnected the old defrost heater removing 2 small screws and the electrical connectors, afterward I attached the new part, reconnecting back the electrical connectors and screwing the removed 2 screws.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brad from SPRING MILLS, PA
- Parts Used:
- WR02X10098
- Difficulty Level:
- Very Difficult
- Total Repair Time:
- More than 2 hours
Noisy
I didn’t do the repair because I ordered two grommets. When they arrived, one of the packages was empty! Instead of just sending me another one, they refunded the part so I still need one. By the way, I was not refunded half the shipping either which was more than the part itself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from DEPEW, NY
- Parts Used:
- WR60X10030
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Broke fan blade cleaning unit
Ordered part came in 3 days. Removed plug and rear cover. Pulled off old fan . Installed new fan by pushing it on to shaft. Plugged unit back in to check operation, installed rear cover. Done. Part fit perfect. Thanks to this site you folks are great !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- THOMAS from MEBANE, NC
- Parts Used:
- WR60X10168
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Noisy Fan Motor
Simple. Rolled the refrigerator out , unplugged the 120 volts AC outlet.(1) Unplugged the wiring from the cabinet to the fan (white (three pin connector)). (2) Removed the two 5/16 inch screws holding the rear motor bracket . (3) Removed the fan blade from the motor shaft by applying slight pressure, pulling if off the old motor shaft. (4) removed the rubber isolator from the frame and from the rear of the old motor. (5) placed the rubber isolators back on the motor and frame. (6) Pushed the new motor back into the frame and re-installed the fan assembly. (7) remounted the fan with the rear support and the two 5/16 inch screws. Reconnected the three wire connector. Just checked the fan blade assembly to make sure they were not hitting the fan shroud. Fan blades should sit just partially inside the shroud to make sure it produces maximum airflow.
(8) Reconnected the 120 volt AC and waited for the compressor to cycle back on... Nice quite fan... Thanks
(8) Reconnected the 120 volt AC and waited for the compressor to cycle back on... Nice quite fan... Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Catherine from SEATTLE, WA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
The light inside the oven had burned out
0. As a safety precaution, unplug the range or hit the relevant fuse breaker before you start. You might also want to grab a flashlight. Definitely do not try to do this while the oven is hot.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
1. Pinch the wire over the light bulb cap to remove it. This is inside the oven at the back.
2. Pop off the hemispherical glass cap.
3. Unscrew the old light bulb, and screw the new light bulb in its place.
4. Put the cap back.
5. Secure the cap by putting the wire back in its slots on the cap.
No tools needed, the cap is just held in place with pressure from the wire.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from BAKERSFIELD, CA
- Parts Used:
- WR60X10030
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Old fan had broken blade, needed to be replaced
Unplugged the refrigerator then used the cordless drill to remove the 6 screws on the access panel on the back of the fridge to be able to get to the fan. Was able to pull the fan off by hand and push the new fan on by hand. Plugged the refrigerator by in and watched the fan run for a few minutes then replaced the access panel. Really quick and easy repair.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Louis from LEAGUE CITY, TX
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Change bulb
Easy
Was this instruction helpful to you?
Thank you for voting!