Customer:
Michael from Portland, OR
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Door closing cams were both broken
Remove screw at hinge cover, top of door.
Remove two screw/nuts at hinge and remove hinge while holding door in place.
Lift door off of lower hinge
remove two nut/screws at bottom of door and replace closing cam. Be sure the pivot pin hole in the cam is lined up with the hole in door.

Next drill out rivet holding cam to lower hinge on the refer. Install cam with a pan head screw and nut (to replace rivet). It will help if you remove the plastic grille cover at the bottom of the frige.

Set door back on the lower pin and shut so the the magnetic strip holds the door in place. Re-install the upper hinge loosely. Adjust the door for an even gap and tighten the screw/nuts. Re-install the cover.

A very easy fix.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Shirley from Toccoa, GA
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
Cam wore out and the door would drop down. To close the door I had to lift it up and close it.
First of all, It was Christmas and no extra money to pay a repairman.
i got on the computer and started looking for a parts breakdown for an older GE side by side.
I finally found it and located the part I thought we needed.
I looked at several parts dealers and yours had the best price.
anyway it arrived in just 2 days. My son helped me remove the door and we put the new part on and I just saved the cost of a service call.

Thank You
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Pradip from Maperville, IL
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
doors were not aligned in height so door was not closing proper and lossing lots of cold air from refrigerator
Door needed to be supported before hinge assembly was removed. After replacing broken cam doors aligned and doors closing properly.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Springfield, MA
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Door wouldn't close by itself. Cam part found on floor.
I removed two screws at the top of the door, lifted the door off. I got lucky: the broken cam was the one on the door (easy to remove), not the one on the body of the refrigerator (tough to remove).
There is a shim which was also broken - no way to know that ahead of time. I bent a 5/8" lock washer flat and it served acceptably as a shim.
It would be helpful if PartSelect.com could include with its listing of the cam, the fact that (1) the shim will probably be needed, and (2) there's a very good chance that you'll need TWO of the cams as well.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eugene from Macedon, NY
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
door dropped when opening and wouldn't stay partially opened
removed top plate and raised the door off. I removed the L bracket from the fridge then noticed the part was rivited onto the L bracket. I cut the rivit and replaced the cam and used a small bolt and nut to sdecure it. Replaced the L bracket, the door, and the upper support. Only problem was the surprise rivit
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
david from pocatello, ID
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
plastic cams on the door broke so the door wouldn't close
Why don't they just tell you that you have to buy 2 cams. I have now replaced the cams on both doors. The other door broke about 4 years ago. Fortunately the first time I read the user commetns or I would've bought just one. It is a quick easy fix. The longest step is drilling out and replacing the rivet. Everything else is done with a nut driver.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Myrna from Wyalusing, PA
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
the cams on bottom of door wore out with age- 20 years
Replaced the old cams with new ones, door works perfect now.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bobby from Danville, VA
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
door dropped down and draging, would not close
Buy ( 2 ) cams !!!! removed hinge cover and hinge on top of the door, ( 2 screws )...lift door off of the bottom hinge and lay door on the floor, remove broken cam on bottom of door with nut driver, ( 2 screws ) , install new cam..... remove the bottom hinge off of the front of the refrigerator with nut driver, (2 screws ).... saw rivit off and remove old cam, install new cam and secure with new bolt and nut,... reinstall hinge back on bottom front of refigerator.....replace door back onto the bottom hinge.....install top hinge back onto the top of the door....replace hinge cover......done !
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lynn from Naples, FL
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Wrench set
Fridge door was not self-closing
Followed step-by-step instructions in previous post. Note that there are TWO approaches, both of which work.

Option 1) Order TWO cams (PS297995), drill out the rivet holding the frame's cam, and replace it with a nut and bolt. (See post on 07/19/09.)

Option 2) Order the entire hinge assembly (PS290199), which includes the door's cam and an assembled frame hinge and cam. (See post on 10/29/08.)

We opted for Option 1 which was pretty easy. Option 2 would be even easier and take less time but costs about $9 more.

Thanks to previous posters for excellent instructions!
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
phyllis from owensville, MO
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Old Cam Had Deteriorated, And Was Breaking Into Pieces And Falling Off.
We taped the door with 3 pieces of duct tape, then put boards under it. Used socket set to remove cam and then cut off rivet so we could just use a screw to keep in place. . . Just for your information, I ordered 2 cams, and was glad I did as I need 2 to make the repair. . . Didn't read about this online or on order recommendation. The cams go 1 up and 1 down thanks for the installation repair stories, it inspired us to "do it ourselves " and we saved about $75 to $100. 00
1 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Chevy Chase, MD
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator door didn't close without a big push.
Took door off. Replaced two cams at bottom of door, referencing those on the bottom of the freezer door. Also followed a video on the net. Worked like a jewel!
Was this instruction helpful to you?
Thank you for voting!
Customer:
Carol J from Alexandria, KY
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Door would not close properly at the last few inches, now it closes good at this time but now need to be raised up to the 5/8 inch as the book says, haven't done that yet
the door closing cam works fine.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from Reno, NV
Parts Used:
WR2X4901
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
Refrigerator door would not close completely.
1. Watched the video on how to make the repair. 2. Used the tools recommended. 3. Followed easy instructions as demonstrated on video, and Viola! It was repaired.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Wheaton, IL
Parts Used:
WR2X4901
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Door didn't shut cleaning, by itself
I watched the video online, and said, "hey, I can do that." And yep, I did. I'm pretty comfortable with handyman work - but had never tackled a frig door before. The door closing cam that had completely come apart turned out to be straight forward to fix with the replacement part.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JOHN E from BRIDGEWATER, NJ
Parts Used:
WR49X392
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Heater not working caused the freezer to freeze up.
Took out old heater and put new one in. That was it.