GST22IBPCWW General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Edward from Florida, MA
- Parts Used:
- WR51X10101
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Freezer was not freezing foods completely or making ice properly. It was running almost 24/7. It was not defrosting and ice was building up on the back wall. The refrigerator food drawers were freezing fruits and vegtables.
Great Service! Received the part the NEXT DAY!
We originally called a service technician. He came the next day and said the mother board was no good. He order a new one and replaced it a week later. Total part & labor cost: $185.00 (Remember we're without a working refrigerator the whole time the part is on order)
Two days later the freezer is doing the same thing. We call the tech again and he seems confused and says it could be the heating element, he'll order one at no charge and replace it for us free. He never comes back with the part and does not answer our 2 dozen phone calls. I checked the element myself and saw that the tube had been scorched, like a burnt out light bulb. Searched for parts on internet and found this great site. "Partselect.com"
REPAIR:
Refrigerator had been unplugged for a few days to defrost ice build up in freezer. First, I removed the shelves from freezer compartment, removed the back panel and removed screws holding heater element in place, I unplugged the two electrical leads and plugged in new part. AS EASY AS THAT !!!!! I reinstalled the screws to hold the element, installed the back panel and replaced the freezer shelves. I plugged the refrigerator back in and within hours the freezer started making ice again. It's been about 3 weeks and we have not had a problem since.
Fantastic Service and instructions and Inexpensive !!!! I will use this site again, if needed, and will recommemd to anyone who needs parts.
We originally called a service technician. He came the next day and said the mother board was no good. He order a new one and replaced it a week later. Total part & labor cost: $185.00 (Remember we're without a working refrigerator the whole time the part is on order)
Two days later the freezer is doing the same thing. We call the tech again and he seems confused and says it could be the heating element, he'll order one at no charge and replace it for us free. He never comes back with the part and does not answer our 2 dozen phone calls. I checked the element myself and saw that the tube had been scorched, like a burnt out light bulb. Searched for parts on internet and found this great site. "Partselect.com"
REPAIR:
Refrigerator had been unplugged for a few days to defrost ice build up in freezer. First, I removed the shelves from freezer compartment, removed the back panel and removed screws holding heater element in place, I unplugged the two electrical leads and plugged in new part. AS EASY AS THAT !!!!! I reinstalled the screws to hold the element, installed the back panel and replaced the freezer shelves. I plugged the refrigerator back in and within hours the freezer started making ice again. It's been about 3 weeks and we have not had a problem since.
Fantastic Service and instructions and Inexpensive !!!! I will use this site again, if needed, and will recommemd to anyone who needs parts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- HUAHUI from NEW HYDE PARK, NY
- Parts Used:
- WR51X10101
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Refrigerator cannot generate cool air
I bought the GE Refrigerator about 4 years ago for about $1500. The defrost Heater failed about one year ago. Then I called local repair guy, he replaced the Defrost Heater and charged me about $250. Now it happened again. I think we should try it to fix it by myself. I found the parts from partselect.com, it costs me $50 with 2-3 days shipping. After it replaced, it works fine again.
Note: Symtom: cannot make cool air, Frozen area with frost on the wall. Regeriator "leaking water" on floor since iced food started to melt...
Solution: open the cover of the wall inside of frozen zone, use hot water to defrost it gradually. removed the failed Defrost Heater and replaced it with new one.
Note: after you defrost the area inside of the wall, your refrigerator will work normally without the Defrost heater without any issue about week while you are waiting for the parts coming.
Note: Symtom: cannot make cool air, Frozen area with frost on the wall. Regeriator "leaking water" on floor since iced food started to melt...
Solution: open the cover of the wall inside of frozen zone, use hot water to defrost it gradually. removed the failed Defrost Heater and replaced it with new one.
Note: after you defrost the area inside of the wall, your refrigerator will work normally without the Defrost heater without any issue about week while you are waiting for the parts coming.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Philip from Los Alamos, NM
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Cabinet very hot on sides, freezer not 0, running continuously.
Diagnosis of symptoms was condenser fan not running, due to faulty main board.
First: removed the cover over the main board, which was too hot to touch. Bad design flaw, no ventilation for the board, which I believe made it fail. We got another year of service with the cover removed.
Second: after reading people's experiences here, ordered the board and popped it in. (Note: needed a pliers to compress each of the 4 plastic studs holding the board in.) Works like a champ.
Third: did NOT replace the cover. At our altitude the air can't conduct enough heat to prevent cooking the board. Need to allow circulation.
First: removed the cover over the main board, which was too hot to touch. Bad design flaw, no ventilation for the board, which I believe made it fail. We got another year of service with the cover removed.
Second: after reading people's experiences here, ordered the board and popped it in. (Note: needed a pliers to compress each of the 4 plastic studs holding the board in.) Works like a champ.
Third: did NOT replace the cover. At our altitude the air can't conduct enough heat to prevent cooking the board. Need to allow circulation.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Akron, PA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Compressor Would not come on. Found the relay on the Main Board burned up. There was no electrical power to the compressor .
Ordered a new Main circuit Board. It arrived next day. Unplug the fridge to take away electrical power. Unscrewed the panel on the back of the fridge near the top. I then pulled the wire connectors off the circuit board. Gently pull the board off the plastic tabs. Push the new board onto the tabs. Reconnect the wire connectors. Screw the panel back on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from Ellicott City, MD
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Refrigerator ran too much, condensor fan not running
Removed cover plate on rear of unit - 3 screws
Removed connectors and ground wire
Removed board (use needle-nose pliers to compress plastic mountig posts)
Replaced board, inserted connectors, attached ground wire, put cover on
Everything worked properly
Removed connectors and ground wire
Removed board (use needle-nose pliers to compress plastic mountig posts)
Replaced board, inserted connectors, attached ground wire, put cover on
Everything worked properly
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Barrington, IL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Freezer never kept a consistant temperature. One night heard a clicking noice which was followed by the temperature display showing temps like -31. Researched to find other with the same issue and ordered the replacement board to repair.
I must admit - I thought I'd attempt to do this repair and end up calling a service guy to finish it. I'm not mechanically inclined AT ALL but thought I'd give it a shot after reading others experiences. I'm glad I did. The fix was easy, but there was initial anxiety while reading the instructions that came with the part - as they mentioned the possible need to cut some wires. Fortunately that was not necessary..... Removed three screws from the rear plate to expose the part needing to be replaced. Remove the fittings from the old board (needed plyers to do that - be gentle), take the old board out by using needle nose pliers to squeeze the white plastic tabs and pull the board free. Reconnect fittings to new board and you are done. Works better now than ever - obviously the old board had an issue that GE should have recalled, as many others had the same problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rene from HEBER, CA
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
condenser icing refrigerator warm freezer ok
follow the easy instructions replace 3 temperature sensors cut the wires and crimp them with new sensor and it works like new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Sharon from West Winfield, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers
The fridge was making a clicking sound, and not cooling the food
The back panel was unscrewed, we read the directions with the circuit board and followed them. It was very easy to unplug the old faulty unit and plug in the new replacement part. It was done in 4 minutes flat. Very easy to do yourselves!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- anthony from Hampton, NJ
- Parts Used:
- WR50X10068, WR55X10025
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Defrost cycle would not cycle off
Replaced Defrost Thermostat. Tricky removal of light fixture cover and evaporator cover. Light cover screw removal is not intuiitive and the eveaporator cover tabs are not easy AT ALL to remove.Once they are removed, simply 2 screw removal of rear panel.
Had to unscrew screws holding cooling coils to gain access to thermostat mounted on a coil in rear.
Simkple matter to cut wires, remove old thermostat and splice replacement back on. Found it simpler to re-mount thermostat on top coil greatly simplifying process.(Why didn't they place the original unit in this much more accesible place?)
Re-attach coils to rear wall replace rear panel, light fixture cover and evaporator cover.
Refrigerator has been running fine this past week.
Received parts NEXT DAY! FANTASTIC!
Had to unscrew screws holding cooling coils to gain access to thermostat mounted on a coil in rear.
Simkple matter to cut wires, remove old thermostat and splice replacement back on. Found it simpler to re-mount thermostat on top coil greatly simplifying process.(Why didn't they place the original unit in this much more accesible place?)
Re-attach coils to rear wall replace rear panel, light fixture cover and evaporator cover.
Refrigerator has been running fine this past week.
Received parts NEXT DAY! FANTASTIC!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eileen from Coto de Caza, CA
- Parts Used:
- WR23X37285
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers
switchlight on my refrigerator was not working
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Glenn from PORT JEFFERSON, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Ghostly Sounds From Fan Motor - Variable Speeds All Night - Motherboard Problem
Simple directions were provided. It took more to clean and vaccuum than the actual repair. Yes I replaced the motherboard in a referigerator. Just keep not of the connectors and were they came off from on the original board. Dont just rip them off because the new board has some different connections. So follow the directions and take your time if your not sure. But really it a cinch. No more whoooo sheeesh and howling noises from the referigerator. Thank goodness.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- james from vista, CA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
Making an owl sound from the icemaker side
Simple; Removed the panel, unplugged the cable connections to the mother board with a rat nosed plier.
Then to remove board you must squeeze closed the 4 plastic retainer clips in each corner, or they can accidentally be pulled off with the board.
Removed the board, re-attached the new board on the clips, then the cable connectors, then the panel.
Plugged in the refrige and it has been silent ever since.
Follow the instructions and anyone can do it.
Then to remove board you must squeeze closed the 4 plastic retainer clips in each corner, or they can accidentally be pulled off with the board.
Removed the board, re-attached the new board on the clips, then the cable connectors, then the panel.
Plugged in the refrige and it has been silent ever since.
Follow the instructions and anyone can do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Desiree from Greensburg, PA
- Parts Used:
- WR60X10220
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Ref was not freezing correctly
took back cover off. swept the rear with a vacuum cleaner to get rid of dust.found that the fan would not turn. ordered part with your really great ordering technique. Part was suppose to be here in 3-5 days and was here the next day!!!.Removed 2 bolts pulled out the plastic clip that held the wire on. and worked the fan blade off shaft. removed and replaced in the same order as taking simple Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jennifer from Highlands Ranch, CO
- Parts Used:
- WR71X38317
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Dairy door broke
Put the new one in--simple!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Wylie, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Not cooling, Defrost issues, whining loud noises
Unbolted the back cover, pulled out old board, replaced with new bored and powered back on. It is working great now.
Was this instruction helpful to you?