Customer:
Scott from SMITHS GROVE, KY
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Replaced Dispenser Solenoid Assembly
We had problems with the ice dispenser chute building up frost from condensation freezing due to the flap not closing properly. It would clog up completely and often. I had already replaced the flap and spring years ago but it didn't help much. I Googled this problem for my model and found a video detailing how to check and change the solenoid. Sure enough, the solenoid was completely corroded and crumbled in my hands as I removed it. I ordered the replacement part and made the repair myself. The video was perfect in describing. If your refrigerator is well used as ours is, you'll be shocked by the buildup and cleaning that will be necessary as you make this repair. I ended up taking much more of the dispensing assembly apart so I could clean it with warm soapy bleach water. Be mindful as you disassemble or take photos / videos with your smartphone to help put it back together. It took longer to clean than replace the solenoid. Also, be careful if you have an island or other cabinetry close by. If you have to pull the refrigerator out to unplug it, the handles can chip granite edges or the top corners can scratch wood work. We have cherry cabinets that surround ours. I chipped the edge of the granite when I pulled it out and I scratched the wood as I pushed it back in place. Minor repairs but can save you some frustration. Good luck!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from VANCOUVER, WA
Parts Used:
WR01X37886
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Water dispenser bulb burned out and needed to be replaced
Unscrewed old bulb, inserted and screwed new bulb into place
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from TYLER, TX
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Your video was wrong. Your step was to remove exterior frame on ice/water outlet. No need to remove.Wasted too much time trying to remove.
Remove control panel.
Remove four screw in control panel bracket.
Remove to bottom screws at bottom of solinid loose top screw.
Replace all screws.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
george from MIAMI, FL
Parts Used:
WR01X37886
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
light bulb at water dispenser not working.
unscrewed old bulb and screwed in new bulb. checked and new bulb works great. less than five minutes to complete.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from MORENO VALLEY, CA
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Water dispensed at a trickle
I only had to remove the old filter and install the new one - all by hand. I then ran about 1 to 1and1/2 gallons of water through the filter to clear it.
A WORD OF CAUTION - HOLD YOUR GLASS CLOSE TO THE WATER DISPENSER FOR THE INITIAL FILLING - IT WILL SPIT UNTIL THE AIR IS PURGED FROM THE SYSTEM!!!
An extremely easy repair.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from W Berlin, NJ
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice forming around shoot. Flapper door not shutting letting warm air in.
I followed they instructions from the other "do it your selfers" but only replaced the solenoid. This was the cause. Rust was keeping solenoid plunger from moving and this held the flapper door open. Very easy to repair!
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Sandy Hook, CT
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice chute wouldn't open or shut correctly - rusted solenoid
Replaced rusted solenoid.

Popped front button panel off from the bottom using flat head screwdriver; Removed 4 screws holding electronics board and disconnected wires. Unscrewed 3 phillips head screws on old solenoid and replaced with new part. Reconnected wires to board, screwed back in, and pushed panel back into to place.

Thumbs up to PartSelect - fast, straightforward service and fast delivery.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jeff from stillwater, OK
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
solenoid quit working
repair was easy, just removed control panel and removed screws from solenoid, switched out with new, was done in minutes
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Newburg, MO
Parts Used:
WR17X11267, WR17X11170
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Water didn't always shut off when you removed your cup. Thought it was just the spring but on disassembly found broken plastic that was preventing the spring from working properly.
- With a plastic thin putty knife remove the trim panel around the water dispenser. There are plastic clips along each side that just need to be slid inward slightly to release the trim. The thin plastic putty knife worked great for this.
- Remove the electronic panel by pushing the top of the panel down slightly to pull out at the top. The bottom will then come out easily. Remove all electrical connections so the board can be detached completely.
- Unscrew the four screws at the corner of the Dispenser Housing Shield. Before removing, note the position of the wire runs for re-installation.
- Take some pictures of how the old Ice Funnel is attached then remove it and reinstall the new Funnel.
- Make sure wires are in their proper place before screwing the Dispenser Housing Shield back in place with the four screws.
- Connect wires to back of electrical panel and angle the panel into the proper place at the bottom and then pull down slightly to go in the top.
- Reattach the trim by gently pressing the plastic tabs into each slot.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from AVON, OH
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flap on ice maker would not close
First tried just replacing flap/spring and mounting. Still did not work so then order a new solenoid with piston that attaches to mounting. That solved problem completely. Corrosion around piston prevented fluid movement of flap. Easy fix after watching video. Saved a bundle I'm sure. Thanks !!!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
david from LANSING, NC
Parts Used:
WR62X10055
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
broken Ice maker dispenser
with a philips screw driver and that's all it was that easy
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from FORT MYERS, FL
Parts Used:
WR62X10055
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The flapper on the ice dispenser would not close after you dispensed ice cubes
Removed face plate, which holds the circuit board. Removed the next section be removing the 4 screws that hold it in place. Then removed the old solenoid, and replaced it with the new one.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Brian from BOZEMAN, MT
Parts Used:
WR02X12008, WR02X10540
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Noisy Freezer Evaporator
Find a video on youtube. Remove 6 screws. Pull the Styrofoam part up before removing the panel. Unplug and Remove the fan assembly.
You will need a NUT DRIVER to take the bracket off the backing plate.
I ordered the red grommet and the red bumper. You need TWO of the red grommets if that is the problem. My freezer was about 8 years old, and the grommets were worn and compressed, the bumper was not. Replacing these parts DID NOT FIX the problem. I needed a new motor.
I probably disassembled and reassembled this stuff about 7 times before I got all the parts and tools. Each time I had to unload the freezer.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kent from Bartlesville, OK
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Colin from Saint Helena Island, SC
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Bad Solenoid Not Closing Ice Dispenser Door
Followed the on line video. Clear, concise & easy. Thanks.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!