James E from SYRACUSE, NY
Parts Used:
WR17X11497
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Was dispencing way too much ice all over the floor.
Like I said I was getting too much ice. Typed it in on google and this site was one of the listings. I went to your site and found out the ice crusher cover was broken. The broken pieces in my glass with the ice cubes was another indication but I didn't know what it was called. I watched the video before ordering and I figured I could do this so I ordered the part. 3 days later it was here so I took the ice bin out of the freezer and let it get warmed up like the guy said in the video. I watched the video while the part warmed up. Now its time to start. I kepted the video on the computer screen just in case. I took my time and about 30 min I was making ice again. "WATCH THE VIDEO" Thanks for having this for me to watch. Made the job a piece of cake!
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JOHN from west End, NC
Parts Used:
WR01X10315
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
Stripped threads auger nut
removed ice bucket from frig. removed screws to dis assemble the box to get to the auger assembly,removed stripped nut replaced reassembled be care not to let the rest of the assembly fall from auger there are a lot of blades and spacers to try to get back to proper position.
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from MC GRANN, PA
Parts Used:
WR17X10703
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Ice deflector was broken
took off the front panel, removed the auger and front piece, removed the pin and spring and installed them on to the new piece and then put everything back together
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Jacksonville, FL
Parts Used:
WR17X11497
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Excessive Ice Flow
Once the icebin is removed, the disassembly is pretty straight forward:
-Remove all ice and allow the ice bin to reach room temperature, because frozen plastic will crack easily.
-Remove the 2 philips screws on the bottom front and release the 2 tabs on the top of the cover unit.
-Disengage the steel rod, but first make note of the spring position.
-Lift the inner assembly out from the main front bin unit, which will remove the ice screw in the process.
-Disengage the ice screw and carefully twist the crusher plate around the screw.
-Manipulate the new crusher plate around the flanges of the screw, be patient, as this can be a time consuming endeavor until you finally find the right twisting location to enable the new crusher plate to clear the flanges of the screw.
-Once in position, reattach the entire assembly and rod back into place.
-Just take your time and make note of all removed component locations.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from CHARLESTON, SC
Parts Used:
WR29X10085
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
The left three tines bind and break off because they don't match the part removing the ice.
The right side of the three left three tines must be shaved about 1/8" to allow the ice remover blades to pass unimpeded.The part should be manufactured better.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Harry from DURYEA, PA
Parts Used:
WR55X10025
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Lewisville, TX
Parts Used:
WR17X11505
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice drawer crusher dispenser cover lid broke and allowing ice to freely drop from dispenser
Ordered ice crusher dispenser cover removed 3 screws and face plate of ice crusher was easily replaced and again working like new
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bryan from Fairfax, VA
Parts Used:
WR62X10055
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer frosting up around ice dispenser chute.
Ordered new solenoid so the flap would close. That did the trick.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kyoko from Bellevue, WA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
frost/ice buildup in icemaker chute in the freezer door
The only difficult part was not knowing which parts had to be removed to gain access to the flapper to replace it. It appeared as if the frame around the control panel would have to be removed as well as the door handle; we tried but were not able to remove the frame. It turned out that the panel just popped out with the frame in place. Once we had access to the flapper, it was easy to replace it. The repair fixed the problem.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter M. from Lincoln Park, NJ
Parts Used:
WR02X10540
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from Kennesaw, GA
Parts Used:
WR17X11653, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Ice Maker Door Leaking Air Causing Inside To Ice Up.
The allan wrench pushes into the holes nder the front control plate and it pops off. Unplug the wires and set aside. Four screws removes the next piece and the "flaper" door is visable.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from ROSEMOUNT, MN
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rick from VACAVILLE, CA
Parts Used:
WR17X11653, WR17X10706, WR02X10585
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
ice door not closing
looked at the video you supplied for repair.. that made it so easy to repair the problem. I felt quite confident in myself after the video.The repair went smoothly and the refridgerator wotks super thank you so much Rick
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Robins, IA
Parts Used:
WR62X10055, WR17X11653, WR23X10783, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Pliers, Screw drivers
Ice chute flapper would not close all the way
Following the advice of others on this site, I popped out the control panel by pushing up through the 2 outer-most holes on the under-side of the panel (the middle hole is unused). I installed the new solenoid exactly as shown in the PartSelect video. The new crank, spring, and flapper installed easily as well; I did apply a little grease to the hinge points on the crank to ensure no binding. I also installed a new microswitch. The wires are best removed from the old switch with a needlenose pliers. The old switch looked like it had some grease on the switch (where it makes contact with the cup lever) so I put some grease on the new switch as well. All-in-all, very easy and the frig works like new. It's nice to hear the flapper slam shut 4 seconds after dispensing ice.
4 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Milford, NH
Parts Used:
WR62X10055, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
flapper movement both directions
Replacing was easy. Cleaning took the longest. Order screws with parts, I could not find them at the hardware store. I suggest a coat of oil (3 in one) on the solenoid/piston surfaces. I probably did not have to replace them. The rust was inhibiting the piston movement. Some steel wool and oil would have probably fixed it. If the flap closing starts sounding softer, I'm going to take it apart and clean it first.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the RCE25RGBBFKB