Models > GTH18GCDDRWW > Instructions

GTH18GCDDRWW General Electric Refrigerator - Instructions

Jump to:

All Instructions for the GTH18GCDDRWW
16 - 30 of 395
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Joe from Brentwood, TN
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.

Other than the two-screw problem, it was easy.
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from Cave Creek, AZ
Parts Used:
WR30X10093
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
ice maker leaked water slowly and froze the cubes together
The replacement ice maker that GE supplies for my old refrigerator is a little different than the original. The electrical plug changed from a round plug to a square one. They include an adapter for it, but DON'T USE IT. There's not enough room for the bulky cord and connector. I got a much cleaner installation by taking apart the old and the new ice maker, and then splicing in the old connector into the new ice maker. You need to carefully unscrew a circuit board inside to wire it in, and it'll be more secure if you solider 3 wires instead of using crimp connectors. The instructions also tell you to use your old 'ice breaker', but it won't fit on the new ice maker. I just left the new ice maker's ice breaker on, and it seems to work perfect.
41 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
thomas from richmond, VA
Parts Used:
WR57X10033
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
not making ice
when the ice maker runs through its cycle, you should be able to hear the solinoid valve open, letting water into the ice maker. this was not happening for me. you can dissconnect the plug on the valve and put the two probes from a multimeter in the plug and set for AC volts. when the ice maker runs its cycle, at the end you should see the meter jump as power is applied to the valve then turns off. this means you do have power to the valve so the valve is defective. turn off water supply to the valve, disconnect the water supply tube to the valve, remove the screw holding the valve, disconnect supply tube to icemaker then hook up supply tube to bottom of valve, screw braket back to refrig, install suppy back to valve, turn water back on and check for leaks and your ice maker should be working properly again.
these guys were really fast on delivery too!
33 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Dallas, TX
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Wrench set
water appearing under refrigerator
Unplugged the refrigerator and turned off the water to the ice maker valve. Removed the water line at both ends (small crescent wrench). Removed the cover from the water valve area (two Phillips head screws). Removed the valve (two screws - small nut driver) and pulled off the two electrical connections.

Installed the new valve with the reverse procedure though the holding screws didn't line up with the existing holes in the refrigerator metal frame. I let it go with one screw holding ... didn't have a drill with me to make a second screw hole.

Replaced the old water line (from the wall to the valve) with a steel-reinforced hose.

Cut the female metal connector from the old water line up to the freezer and it fit nicely into the push-in outlet from the new valve. Turned everything back on and waited for the ice maker to cycle.
To my dismay, the leak had been coming from the plastic line that goes from the valve up to the ice maker. It had split, spraying water. Replaced that and everything works fine.

Lesson learned: Don't assume water near the icemaker valve actually is from the valve or its water connections. Watch the whole system cycle a couple of times to see what's really happening. Glad to have a new valve but the basic problem was the icemaker tubing.
31 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Lodi, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice was melting and freezing in bucket
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
33 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lucinda from Yucca, AZ
Parts Used:
WR60X31522
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The lower half of the refrigerator was not cold, the fan was not blowing
First I removed the 4 screws in the back of the freezer. I then pulled the connection from the fan , I replaced the fan to the connection, replaced the 4 screws and I was done! I still can't believe how simple it was.
27 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Germantown, TN
Parts Used:
WR09X20002
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Everything was freezing in the bottom and top
Pulled out the control sensor on the ceiling of the fridge. (2 screws) Took a picture with phone on how everything was installed. Unplugged all wires and pulled out Control Temp sensor. Installed new one and attached all wires. Installed back in fridge and plugged it back in. Everything works like new.
23 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
GARY from PARRISH, FL
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Wrench set
Failed Icemaker
Shut off power to the refrige. Removed old icemaker, using large hammer. Installed new unit.
34 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from worthington, OH
Parts Used:
WR9X502
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
refrigerator would not defrost
Look were timer was located, in my refigerator is next to the dial to ajust the temperature. used a screwdriver to get panel off. replaced timer then used a straight screwdriver to advance timer to turn on compessor . monitor temperature . checked out.
21 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from GENEVA, OH
Parts Used:
WR60X31522, WR02X12008
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Loud freezer fan motor
Removed old worn out freezer fan motor and replaced with a new one. Piece of cake. Sooo easy and saved money too!
21 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Glendale, AZ
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
21 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raymond from Concord Twp., OH
Parts Used:
WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set, Wrench (Adjustable)
water valve didn't shut off completly
The valve is not a direct replacement,seems they
are not available,had to bend mtg. brkt. so valve
would mount in same position and cut off screw
type pressure fitting so could slide discharge
tube into new type connection, no instructions
come with replacement valve,asked several
places for info wanted to be sure before cutting
off end of discharge tube. Now valve shuts off
but water still in base of refrigerator must be a
leak in inlet tube behind freezer compartment.
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Islamorada, MD
Parts Used:
WR17X11492, WR02X11437, WR57X10033
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Water leak caused by earlier tube replacement destroying retaining washer in valve
This was a simple parts replacement. I had replaced the cracked plastic tube a few weeks earlier and destroyed the retaining star washer inside the solenoid valve while removing the old one. It worked for a while and then started to leak when the tube had partially worked its way out. The star washer is not a replaceable part so this repair was simply replacing the valve with a new one. It is very straight forward - disconnect the electric plug, remove the old valve, insert the tube in the new valve (it goes through the plastic bushing in the valve - do not remove the bushing - it can easily be mistaken for a shipping plug) and reattach the supply line being careful to avoid kinking it. Reattach the valve, the electric plug and support clips for both the supply line and the plactic line to the ice maker.
18 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jania from Novato, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Simi Valley, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!