Customer:
Tracy from Yuba City, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Stripper on the icemaker broke into pieces.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sharon from Glendale, AZ
Parts Used:
WR29X43990, WR17X11505
Difficulty Level:
Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The Ice Bucket Was Cracket And The Auger Also Broken.
I was able to order the correct parts . Needed my son in law (who in an engineer) to put it together. It was sort of a challenge forhim too. W the persons that I spoke to were very helpful and very nice and the parts came quickly. Thank heavens for the internet. The part that was broken was inside the freezer part of my frig.
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Meridian, MS
Parts Used:
WR17X11168
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench set
Icemaker supply hose leaking at freezer entrance
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Martin from Mount Pleasant, SC
Parts Used:
WR17X11269
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The rubber ice deflector fell off becasue the funnel failed
After removing the front cover to the control panel, I removed the 3 connectors. Then I removed the 4 screws and pulled out the assembly with the funnel.

The I had to lift the plastic tabs on the left and right to release the funnel. Reinstalling the funnel was a little tricker, trying to get the two plastic tabs, the spring and the tab that works the switch all in place at the same time. Then I installed the rubber deflector onto the funnel (the original problem.)

Finally reinsert the assembly, install the 4 screws, attach the 3 connectors, slide the panel back into place starting at the top and then the bottom
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
D from ZELLWOOD, FL
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Heather from Pennington, NJ
Parts Used:
WR51X10101
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
loss of refrigeration
After mopping up the floor - the whole freezer that was iced up melted - that's how I found out about the problem...

Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering the top screw.

With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.

With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.

With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.

Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...

NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherry from Auburn Hills, MI
Parts Used:
WR02X11330
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from Alamosa, CO
Parts Used:
WR60X10220
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Condenser Fan Motor stopped turning
1. Unplugged the fridge. 2. unplugged the fan connection and removed the wire holding clip. 3. removed the 2 screws holding the motor bracket in place and removed the bracket. 4. Pulled gently back on the motor so that the fan pressed against the front bracket until the fan slid off the motor shaft. 5. Pulled the rubber motor mounts off of the old motor and placed on the new motor. 6. Slide the new motor in place pressed the fan all the way onto the shaft. 7. Placed the rear motor bracket in place and started the screws by hand making sure the ground wire was attached to the furthest away screw. 8. tightened the screws down. 9. Pushed in the wire holding clip into the clip hole. 10. Plugged back in the fan. 11. Plugged back in the fridge. 12. Turned down the temp on the fridge to kick on the compressor and checked to assure the fan was operating and then set the temp back to normal. 13. Vacuumed the condenser coils to get them all clean and ready for more years of service!
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
danny from west potsmouth, OH
Parts Used:
WR17X11653, WR17X23191, WR17X10706, WR02X10585
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Ice auger was broke and ice was freezing in the recess door
all parts worked and were easy to install. probably saved me from having to buy a new fridge. ice maker is working fine and recess door flap is closing correctly. very satisfied.
21 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cristina from Los Angeles, CA
Parts Used:
WR30X10093
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jason` from Colchester, CT
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Hanford, CA
Parts Used:
WR01X10315
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Ice Maker auger blade broken
The ice machine auger blade broke a chunk off. I decided to try to replace it myself. I bought the new auger blade and then sat there and stared at it and the ice machine for a few, trying to figure out how to change out the part. Turns out it was a qute lengthy process. The auger is threaded on one end and the ice chopping blades are on it. So I had to take each blade off the old one and put it on the new one. The blades have to be positioned just right on the shaft so it's best to just draw a line down over all the blades so as to put them on the new auger successfully. The problem I had was the end cap that screwed on the end of the shaft. It was the part I ordered here. It is made of plastic with plastic threads and at first I couldn't figure out to get it off. Turns out the threads are opposite normal. By the time I figured that out, I had just about destroyed the cap using pliers to try to unscrew it. There is a washer and half moon clip that fastens on this end nut so if you mess the nut up, chances are you won't be able to get the half moon clip to go back on. I finally did it right and now how the ice maker working right again. A hard part for me was figuring out how to set the spring shaft that works a lever to either give cubed ice or crushed. I had to keep fiddle with it before I finally got that right. At first I was only getting crushed ice even with the cubed setting and then only getting cubed ice with the crushed ice setting. After some fiddling, I got both to work but to this day can't figure out what changes from the crushed setting to the cubed setting.
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Republican City, NE
Parts Used:
WR62X10055, WR17X11653, WR2X8818, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker door failed to close letting ice melt
Removed the front panel on the door that has the ice maker controls. Removed the screws and parts. Reassembled the parts and it works better than new. Ice door closes firmly and holds tight.
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
calvin from annapolis, MD
Parts Used:
WR62X10055, WR17X11653, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers
when dispensing ice the flap door would not open properly and was open most of the time causing the door to ice up...cause solenoid was rusted badly
I removed the screws for the inner door and removed inner lining. Then took out the ice dispenser in the door. Took off control panel on the front of the ice panel. Removed the rusted parts and put in new parts. Put all parts back the way it came apart. In retrospect.... I could have possibly replaced the parts from the front panel but by taking apart the door...I had to thaw out the inner panel and insulation with in the door.
19 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sheila from Robeline, LA
Parts Used:
WR02X11941, WR62X23154
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Wrench (Adjustable)
ice auger drive stripped out, solenoid burned out
removed ice tray, removed drive unit. removed solenoid and replaced, screwed on auger drive. reinstalled drive assembly. replaced ice tray. job done.
21 of 38 people found this instruction helpful.
Was this instruction helpful to you?