joseph from HAMPTON, VA
Parts Used:
WR01X37886, WR17X11267
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Broken dispenser engager
Pretty easy to repair. Only took a few minutes.
16 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Ramona, CA
Parts Used:
WR17X11655
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
The grill flew off going down the freeway.
I took the part out of the package and placed it in the recessed water dispenser/ice maker cavity. Done!
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Kalispell, MT
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Noisey evap motor
I tried to quite the noisey evap motor with special liquid motor grease from Radio Shack. It did not work, so I ordered the evap motor. My freezer motor was wired slightly different than the motor I received. The replacement motor had a male plug attached to the four wires, the original motor was different, so I cut the wires and spliced them into the original freezer wires (colors were the same). Remounted motor. Works great, and no more groaning motor
Peter
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
M Alan from Lebanon, TN
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice maker door didn't open and close properly
I removed the outer plate by sticking a very small screwdriver in the small holes at the bottom of the plate and pulling the plate toward me.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Mahopac, NY
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice maker solenoid failure
several times I had to remove the ice maker door solenoid due to it sticking. I ordered a new one from parts select. Problem solved!!!
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Phillip from Springfield, VA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Ice chute frosted up
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Virginia Beach, VA
Parts Used:
WR49X10233, WR02X12948, WR62X10055, WR17X11653, WR17X10706
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Ice maker not delivering ice, shoot freezing up with condensation.
Your video shows how to make the necessary repairs. Solenoid was the main issue, other parts were replaced to bring assembly to "like new" condition. Over kill but thats how I fix things. All and all a very easy fix. Thanks for the info and parts.
8 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from Elkridge, MD
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Ice Flapper warped and clogged up the Ice Shoot
I bought a Flapper replacement part from Parts Select. I installed it following their very complete on-line video directions. Their complete and easy to follow directions made my job very easy, and the work was completed without any problems and just as good as if it were done by a professional repair person. I am proud of my work, it couldn't have been done without their video insructions. Also I got delivery of the part within two days of my order. I will alway look for Parts Select any time I need an applicance repaired. Thanks to Parts Select!
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Anthony from Miramar Beach, FL
Parts Used:
WR62X10055, WR01X37886
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Frost In Frezer Compartment Where Chute Meets Ice Cube Maker
Removed front panel (using small screw driver) by popping it out, disconnected wire from solenoid, removed solenoid which was rusted, 3 small philip head screws held it in place insereted new solenoid,connected wire snapped front panel back in. Clapper valve closes tightly and no frost in frezzer, saved my self a bunch of money.
10 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from SILVER SPRING, MD
Parts Used:
WR60X24484, WR60X10209, WR02X10520
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Noise coming from rear of fridge
Remove rear plate. Remove fan bracket. Replace fan gaskets, blade and motor. Replace bracket. Replace rear plate. Very simple. Fixed the problem.
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from FARMINGVILLE, NY
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
refrigerator not cold
removed freezer door / shelf /ice maker pulled back panel off and removed fan
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from FRANKLIN SQ, NY
Parts Used:
WR23X10725
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
light not working
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Lincoln, CA
Parts Used:
WR01X37886
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
light burned out
unscrewed lamp and replaced it with new one!
10 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Austin from New Portland, ME
Parts Used:
WR01X37886
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
ice door light bulbs burned out
found the correct bulbs, the hardest part.
un screwed old bulb.
Screwed in new bulb.
Waa La,
There was light.
7 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Federal Way, AL
Parts Used:
WR23X10725
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Difficulty in removing the old switch
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around. If i had ordered the replacement before and not afterwards I would have seen this before hand.
5 of 8 people found this instruction helpful.