ZIS420NXB General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Jack B from Walnut Creek, CA
- Parts Used:
- WR02X12948, MWFP
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Red Spring Broke - Refrig Sect. Door Closure
I found that I did not have the strength to stretch the new spring enough to install it initially. Using a 1/8 or 5/32 inch allen wrench I removed the pivot for the arm that the spring applies tension to. This allowed the spring to be easily attached to the hole in the arm and to the post in the bottom of the refridgerator. I then used a small pliers to grab the arm in front of its pivot hole and pull it against the spring into position to replace the pivot. Replacing the filter was surprisingly easy. I turned the water supply valve off under the sink and easily unscrewed the old filter (about a quarter turn). I filled the new filter with water and srewed in in. No wrenches required. I turned the water back on under the sink and everything works great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christian from chandler, AZ
- Parts Used:
- WR57X10024
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Coroded Water Valve-no longer dispensing water, then leaked water from bottom of fridge
Ordered the replacement parts-both water valves, printed the schmatic, then removed and replaced both parts. Was fairly straight forward, rmeember to unplg the fridge before you start. Problem solved, should be good for another 10 yrs.
Hard water prob caused the corrosion. Also replaced the water hose while I was back there, water tastes 100% better.
Hard water prob caused the corrosion. Also replaced the water hose while I was back there, water tastes 100% better.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Edward from SILVER SPRING, MD
- Parts Used:
- WR60X24484, WR60X10209, WR02X10520
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Noise coming from rear of fridge
Remove rear plate. Remove fan bracket. Replace fan gaskets, blade and motor. Replace bracket. Replace rear plate. Very simple. Fixed the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from NEW YORK, NY
- Parts Used:
- WR02X10520
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Noisy refrigerator
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the grommet facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Peter from Kalispell, MT
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Noisey evap motor
I tried to quite the noisey evap motor with special liquid motor grease from Radio Shack. It did not work, so I ordered the evap motor. My freezer motor was wired slightly different than the motor I received. The replacement motor had a male plug attached to the four wires, the original motor was different, so I cut the wires and spliced them into the original freezer wires (colors were the same). Remounted motor. Works great, and no more groaning motor
Peter
Peter
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ron from ORANGE, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from Keller, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Chip from Mandeville, LA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dean from Folsom, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
The Icemaker failed to make ice
I pulled the refrigerator away from the wall and turned off the water to the refrigerator and unplugged it from the wall. After removing the icebucket from the freezer I located the mounting screws, loosened them, unplugged the electrical connection below the icemaker and carefully removed it from the freezer. I unpacked the replacement icemaker, matched it against the original and attached the electrical connection adapter. Using the slots provided on the new icemaker I placed it over the mounting screws after aligning the water inlet pipe properly. I tightened the mounting screws while maintaining the icemaker in a level position. I plugged in the electrical connector. Then I replaced the icebucket, plugged in the refigerator back into the 110VAC outlet, turned on the water and repositioned the refrigerator in it's normal position.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from FARMINGVILLE, NY
- Parts Used:
- WR60X10185
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
refrigerator not cold
removed freezer door / shelf /ice maker pulled back panel off and removed fan
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- clyde from RIALTO, CA
- Parts Used:
- WR60X24484, WR60X10209
- Difficulty Level:
- Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ROBERT from OCALA, FL
- Parts Used:
- WR49X10283
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench set
Not Cooling
-Pulled refrigerator out to access back.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
-Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
-Removed compressed paperboard cover.
-Found compressor running by the feel.
-Removed metal cover to control board.
-Found ~5V coming from control board to inverter (variable frequency drive) board assembly attached to compressor.
-Found ~120 going to inverter board.
-Removed inverter board assembly from compressor.
-Found equal resistance (~7 ohms for mine) at all three contacts of inverter (DC) compressor.
-Ordered inverter assembly, plus one extra and control board for possible future use so not to loose all my food again; I might order a compressor so I have it before price goes up.
-Installed inverter when arrived.
-Used air compressor to blow out accumulated dust on condenser coil.
-Closed up and cleaned up (C^2).
-Fridge cooled and back to proper temperature the next day.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from San Marcos, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
no ice made
Performed self test.turned off ice maker switch four 5 minutes.Then turn on switch,within 10 seconds,pushed ice paddle 3 times,with 1 second in between each push.Push all the way back and release. Ice maker should cycle and squirt water. My ice maker did neither.I unplugged cord from fridge.So i replaced the ice maker.After a couple of screws had ice again !
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Karen from SAN ANTONIO, TX
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice maker filled too full and ice froze in the basket and a piece was broke on the icemaker itself.f
My son did it , and showed me what he did when he was finished.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Marie from Elk Grove Village, IL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
My ice breaker started leaking and making noise anf the stripper broke.
I ended up needing to order a new ice maker because the one I had is discontinued. I'm a 65yr old grandma and I did it myself!!!! The hardest part was finding the tool to loosed the nuts. I took the old one out and just put the new one right in it's place. Easy as pie.
Was this instruction helpful to you?
Thank you for voting!