Shelly from WATERLOO, IN
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The ice flapper would not go close .
remove the front of were the ice and water comes out
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Roger from Colleyville, TX
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
No water through door dispenser
Replaced flapper valve per website instructions. GE factory technician took two weeks to get here, charged over $100 for the call and told us we needed a new refrigerator door at a cost of over $500 to fix the problem. We sent him packing. After visiting the PartSelect website, the $5.88 PartSelect flapper valve fixed the problem. Amazing.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Damascus, VA
Parts Used:
WR01X37886
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
ice dispenser light wouldn't light
remove old bulb by screwing it out/install new bulb by screwing it in.
5 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Benjamin from Goldsboro, NC
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice flap in door wouldn't close
Take the face (the part with the buttons on the outside) off, disconnect wired connectors (three), take the screws out of the part behind that (4), and then find the solenoid value (on the right). It's attached with three screws. Mine was rusted beyond belief. I knew this was the problem, ordered a new solenoid valve, put it back in place with three screws (use new screws that fit, not the old rusty ones if possible). When testing, make sure you give the flap a couple of seconds to close. There is a delay, and I initially wasn't patient enough so I had to disassemble and assemble an extra time because of this.

Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Fred from LA QUINTA, CA
Parts Used:
WR17X22070
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Replace water filter with bypass plug - filter is redundant with home osmosis system
If you have a reverse osmosis system for filtered water system in your home that also feeds the refrigerator, using another water filter in the refrigerator is redundant, so GE makes a Water filter Bypass Cap that allows you to run using the already filtered water without needing to expensive water filter. FIRST - using a phillips screw driver remove the toe kick plate at the bottom front of the refrigerator - two screws - one on each side of the plate that extends the entire width of the refrigerator. SECOND - Locate the water line (should be right in front) and the valve to turn off the water. Turn valve clockwise (right) until completely closed. Then test by attempting to fill a glass with water using the dispenser on the door. If any water continues to come out, continue turning the valve (without forcing it) clockwise until it has been turned as much as possible. If water still comes from dispenser, locate the source of the water line - most likely from under the kitchen sink. There should be another valve under the sink, or simply turn off (turn the cold water valve clockwise) until water cold water completely turned off. Test again as required. THIRD - clear the top right hand back shelf directly under the water filter screwed into the ceiling of the refrigerator in the rear top right side of the refrigerator. Place a small towel under the water filter, and slowly turn the filter 1/4 turn clockwise without using force. Continue turning until the full 1/4 turn is complete and the filter will drop down without pulling. Place the old filter upside down in the sink, thereby allowing the filter to drain any water present in the filter. FOURTH - remove the filter plug from package, notice notches in top of plug that align with gaps in the area where a filter would typically be screwed into the filter location in the ceiling above the top right shelf in the refrigerator. After aligning notches in the bypass plug with gaps in the screw mechanism, carefully turn the bypass plug 1/4 turn counter- clockwise - at which time the bypass plug should be firmly installed. FIFTH - Reverse step SECOND, and turn valve Counter-Clockwise until valve is completely open. Test to ensure no water is leaking from the Bypass Plug. SIXTH - Finally reverse step FIRST by reattaching the toe kick plate using the two phillips screws removed in Step FIRST. NOTE: The Bypass Plug is quite inexpensive, but after adding shipping from Canada - the cost is about the same as purchasing a new filter for the refrigerator. :-(
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward N from Boyds, MD
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker Door flap would not close all the way
Went on this site, found out many others like me had the flap door stuck open problem, it would not shut after you went for ice. I needed a new solenoid that opens when the ice is dispenced and closes afterwards not allowing the warm ambient air to come up the shoot which frosts the ice and melts it. It shipped QUICK and now I have a working ice maker dispenser from the outside. Its been 2 YEARS of opening the door and reaching into the ice maker bin for ice! Thanks PartSelect
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Los Angeles, CA
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Door flapper would not self-close
I replaced the original solenoid, which had rusted into one solid piece. OMG how easy was that!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
susan from hartford, WI
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Bad tasting ice cubes
Took the old filter out and put the new one in.
Easy Breezy!!
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alex from Cary, NC
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Frost buildup in freezer by the ice maker
Replaced dispenser door flapper by following the do it yourself video in this site. It was really easy. Just be careful when removing the dispenser black bezel. I broke one of the little tabs when taking it off.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rudy from CITRUS SPGS, FL
Parts Used:
WR17X11653
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Had a drip which filled up the tray and leaked on the floor from water dispenser
There are Great videos on YouTube!!! Turned off power,Removed trim ring, Pushed a philips head screwdriver in one of the holes underneath the electrical panel with the selector push buttons. This releases the electrical panel. There are Three wire sets with plugs. I removed the plugs and took the electrical panel out. Removed four Phillips head screws and pulled out the big paddle switch. This then exposes the flapper. Replaced flapper with new one and reassembled everything. When I had everything apart, I cleaned with window cleaner. It was pretty moldy from the water leaking. Turned power back on and tested everything to make sure I didn't mess anything up. Works great
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from FORT MYERS, FL
Parts Used:
WR62X10055
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The flapper on the ice dispenser would not close after you dispensed ice cubes
Removed face plate, which holds the circuit board. Removed the next section be removing the 4 screws that hold it in place. Then removed the old solenoid, and replaced it with the new one.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from MORENO VALLEY, CA
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Water dispensed at a trickle
I only had to remove the old filter and install the new one - all by hand. I then ran about 1 to 1and1/2 gallons of water through the filter to clear it.
A WORD OF CAUTION - HOLD YOUR GLASS CLOSE TO THE WATER DISPENSER FOR THE INITIAL FILLING - IT WILL SPIT UNTIL THE AIR IS PURGED FROM THE SYSTEM!!!
An extremely easy repair.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Justin M from Cypress, TX
Parts Used:
MWFP, WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice door gasket warped would not seal
Pop off the control board for the ice selector/water. Remove power / signal connections. remove four phillips screws, Remove plastic hopper. Pop off Ice door gasket, pop in new one and put back together. If you fridge was sounding like it was speeding up and slowing down, this will correct this problem as well.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from VANCOUVER, WA
Parts Used:
WR01X37886
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Water dispenser bulb burned out and needed to be replaced
Unscrewed old bulb, inserted and screwed new bulb into place
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
george from MIAMI, FL
Parts Used:
WR01X37886
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
light bulb at water dispenser not working.
unscrewed old bulb and screwed in new bulb. checked and new bulb works great. less than five minutes to complete.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!