- Customer:
- michael from west bend, WI
- Parts Used:
- WR17X11170, WR49X10233
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
The unit will not dispense water, but does make and dispence ice.
I replaced that part, but I still have the same problem, no water is dispensed. I believe I may need a circuit board. The problem was not the parts I replaced.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Auburn, AL
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice machine wasnt making ice
First I turned the refrigerator and water line off. Then moved to the freezer section, followed the directions, removed the two screws. Directions state to not remove them but I had to in this case. Unplugged the ice maker and removed it from the freezer. I installed the two mounting screws then tried to plug the electrical connection back in but had to use the adaptor cord furnished in the kit. The cord was a little long but I tucked it in and mounted the ice maker. Turned it on then turned the refrigerator and water back on and in a few hours had ice! Very easy to do!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- robert from bensalem, PA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken ice maker
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Somers Point, NJ
- Parts Used:
- WR23X37285
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
10 minutes total.
10 minutes total.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ernest W. from Charlotte, NC
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker Stripper lost a tooth
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the new stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- mike from Aguilar, CO
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas R. from Lexington, NC
- Parts Used:
- WR57X10023
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Socket set, Wrench (Adjustable)
Valve was leaking at end-cap
Shut off water supply to refrigerator. Unplugged electrical supply. Removed waterline from valve and valve from refrigerator. Disconnected electrical connections to valve. Disconnected water supply from valve to refrigerator. Repeated the process in reverse order using the replacement valve. Checked water in refrigerator door for proper operation and monitored area around valve for leaks before rolling refrigerator back into cabinet space.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Graeme from Sarasota, FL
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Icemaker flap not closing, frosting up
Watched video, however could not get outer casing off. Under the panel are three small holes, pushed up with an Allen key, used a small screwdriver to wedge out, came out easily, followed instructions from video on removing and replacing solenoid
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- GEORGE from ELIOT, ME
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Will not make ice
Bing , Bang, Boom.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Anthony from CAMBRIDGE, MA
- Parts Used:
- WR49X10283
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Frig stopped working
Tested the circuits then the inverter and found that to be no good. There was no 277 voltage leaving the inverter. Ordered new and replaced. The frig is now working fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tim from The Woodlands, TX
- Parts Used:
- WR17X11653
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- scott from lake orion, MI
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
Ice maker door not opening
Removed panel from front of freezer door by pushing up on three spring loaded screws located in the opening where the ice door opens and closes. they are about 1 inch apart on the bottom of the opening. Push up to free ice maker panel. Remove three screws from solenoid, located at the top right. Remove wire, replace with new and that is it. Fixed the problem!! Our ice maker hadn't worked for months. Be careful if you remove the round ice maker door to clean. There is a spring that located on the left side of sprocket. The spring fell off and took me a while to figure where it came from. Recieved package in three days and the job took minutes. Works great! Very easy to complete.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Greg from Eden prairie, MN
- Parts Used:
- WR57X10023
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Socket set
Water Leaking from behind refrigerator
Turn off water to the refrigerator and unplug from wall outlet remove the defective inlet valve replace with new inlet valve. Now is a great to clean use a air compressor and vacuum and your old crusty frige will be good as new ! Special thanks to Parts Select fast shipping and original ge parts!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Tampa, FL
- Parts Used:
- WR57X10023
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
leaked
replaced water valve for 50 dollars, saved about 200 dollars by doing it myself
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Charles from ORO VALLEY, AZ
- Parts Used:
- WR49X10283
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers, Socket set
Compressor would not kick on and condenser fan ran constantly
Remove back panel on bottom of fridge to access compressor area. Remove screws from water solenoid and water valve and push to the side so the side of the compressor can be accessed. Then locate the inverter box. You will find a Phillips head screw on the bottom of the inverter. This is the only screw that hold the inverter in place. Remove the screw and tilt the inverter box forward away from the compressor, then lift the box out of the the holder. You may have to wiggle it a bit to get it out. Remove the plug that attaches to the compressor and then with the power on check your voltage coming to the compressor. It should read 120 volt. If it doesn’t your inverter is bad. Remove the other plug on the inverter box and pull the box out.
Reinstall the unit in reverse order. Use the appropriate jumper to plug into the wire connection going to box and then plug it into the connection off the fridge.
Once everything is reinstalled and before you put the back panel on plug your refrigerator back in and you should be able to hear the compressor working or feel the top of it to make sure. If it’s working you are good and can reinstall the back panel.
It will take 4-5 hours to come back to temp if it’s been off for any length of time.
Reinstall the unit in reverse order. Use the appropriate jumper to plug into the wire connection going to box and then plug it into the connection off the fridge.
Once everything is reinstalled and before you put the back panel on plug your refrigerator back in and you should be able to hear the compressor working or feel the top of it to make sure. If it’s working you are good and can reinstall the back panel.
It will take 4-5 hours to come back to temp if it’s been off for any length of time.
Was this instruction helpful to you?
Thank you for voting!