Customer:
Richard from Coppell, TX
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice dispensor door would not open all the way and did not close
I used a mirror to locate the two small plastic tabs located on the underside of the ice dispenser light. I used a small flat blade screwdirver to push the plastic tabs forward to release the ice/water selector unit. I read about someone that did not see the tabs and ended up removing the inside of the freezer door, a two hour task! The ice and water control unit then slides out. remove the four rusty screws holding the dispensert and ice chute, the selenoid isthen easy to see.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Benjamin from Goldsboro, NC
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice flap in door wouldn't close
Take the face (the part with the buttons on the outside) off, disconnect wired connectors (three), take the screws out of the part behind that (4), and then find the solenoid value (on the right). It's attached with three screws. Mine was rusted beyond belief. I knew this was the problem, ordered a new solenoid valve, put it back in place with three screws (use new screws that fit, not the old rusty ones if possible). When testing, make sure you give the flap a couple of seconds to close. There is a delay, and I initially wasn't patient enough so I had to disassemble and assemble an extra time because of this.

Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bryan from Fairfax, VA
Parts Used:
WR62X10055
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer frosting up around ice dispenser chute.
Ordered new solenoid so the flap would close. That did the trick.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randall from NORTHFIELD, MN
Parts Used:
WR17X11267
Difficulty Level:
Very Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The indoor water occasionaly stops working due to the waterline in the door freezing.
I applied heat to the area with a hair drier. Used a little too much heat and deformed the ice funnel which also controls the water spigot. Ordered a new ice funnel from PartSelect. Part arrived in about a week and included a schematic of the mechanism which made disassembly and reassembly very easy. In a short time everything was working like new.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Los Angeles, CA
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Door flapper would not self-close
I replaced the original solenoid, which had rusted into one solid piece. OMG how easy was that!
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward N from Boyds, MD
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker Door flap would not close all the way
Went on this site, found out many others like me had the flap door stuck open problem, it would not shut after you went for ice. I needed a new solenoid that opens when the ice is dispenced and closes afterwards not allowing the warm ambient air to come up the shoot which frosts the ice and melts it. It shipped QUICK and now I have a working ice maker dispenser from the outside. Its been 2 YEARS of opening the door and reaching into the ice maker bin for ice! Thanks PartSelect
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from st aug, FL
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
the cecular door for the ice was geting stuck opened
with a small screwdriver push in tabs in upword movement to remove the face cover for the three botons of ice crushed ice and water .
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter M. from Lincoln Park, NJ
Parts Used:
WR02X10540
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jay from Oceanside, CA
Parts Used:
WR23X10783
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Water dispenser would not fill a glass completely
The trouble with DIYers is that they don't have very much experience with and the benefit of several repairs on the same appliance. So they must rely on their mechanical abilities and the youtube help of Steve. So they must resort to eliminating the variables as their diagnostic approach. In my case I was unable to find the exact description of my problem, so I began with what seemed like the most likely and the least expensive replacement. So after I had replaced the water valve, the micro switch and the main board I finally found the problem was the water filter by ordering and installing a water bypass valve which I did not have readily available at the start.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Fishers, IN
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice Maker Door fails to close
1. Remove outside panel (snaps off)
2. Remove Control panel 4 screws
3. Remove Solenoid by taking out 2 bottom screws
4. Remove solenoid weight from crank lever
5. Place new solenoid weight from crank lever
6. Insert weight in solenoid
7. Place back 2 bottom screws solenoid
8. Place back Control panel screws
9. Snap back into place outside panel
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
jeff from stillwater, OK
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
solenoid quit working
repair was easy, just removed control panel and removed screws from solenoid, switched out with new, was done in minutes
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
JAMES from MORENO VALLEY, CA
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Water dispensed at a trickle
I only had to remove the old filter and install the new one - all by hand. I then ran about 1 to 1and1/2 gallons of water through the filter to clear it.
A WORD OF CAUTION - HOLD YOUR GLASS CLOSE TO THE WATER DISPENSER FOR THE INITIAL FILLING - IT WILL SPIT UNTIL THE AIR IS PURGED FROM THE SYSTEM!!!
An extremely easy repair.
3 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Sandy Hook, CT
Parts Used:
WR62X10055
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice chute wouldn't open or shut correctly - rusted solenoid
Replaced rusted solenoid.

Popped front button panel off from the bottom using flat head screwdriver; Removed 4 screws holding electronics board and disconnected wires. Unscrewed 3 phillips head screws on old solenoid and replaced with new part. Reconnected wires to board, screwed back in, and pushed panel back into to place.

Thumbs up to PartSelect - fast, straightforward service and fast delivery.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from W Berlin, NJ
Parts Used:
WR62X10055
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Ice forming around shoot. Flapper door not shutting letting warm air in.
I followed they instructions from the other "do it your selfers" but only replaced the solenoid. This was the cause. Rust was keeping solenoid plunger from moving and this held the flapper door open. Very easy to repair!
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
susan from hartford, WI
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Bad tasting ice cubes
Took the old filter out and put the new one in.
Easy Breezy!!
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ZISS42GDXASS