ZSEP480DYASS General Electric Refrigerator - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Richard from Kingsport, TN
- Parts Used:
- MWFP
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Scheduled replacement
Turned the old filter loose, removed the adapter from it, put the adapter on the new filter and turned the new filter back into place.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Secretary, MD
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Ice chute door not closing
I read instructions in all of the other repair stories everything went smooth no problems. Went and examined freezer door too see which type of door I had front or rear access. Popped off front LED panel, unpluged wires, removed 4 screws holding ice chute, removed 3 screws holding solenoid, slipped off solenoid pin, replaced all items in reverse order. This is one great site.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wanda from FRANKLINTON, LA
- Parts Used:
- WR01X37886
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Dispenser light bulb
Screwed bulb in and Light works!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Don from DYERSBURG, TN
- Parts Used:
- WR17X22070
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Slow water flow from water dispenser.
Took out the MFW filter.
Screwed in the MFW bypass.
Dispensed several gallons of water.
Saw good flow of water.
Removed MFW bypass.
Replaced MFW filter.
Our water flow was back to normal.
Screwed in the MFW bypass.
Dispensed several gallons of water.
Saw good flow of water.
Removed MFW bypass.
Replaced MFW filter.
Our water flow was back to normal.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Thomas from Lake George, NY
- Parts Used:
- WR62X10055, WR17X10706, WR02X10585
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The ice dispenser door would not open or close.
It was actually very easy. You simply remove the display cover (you just want to be careful removing the display cover so as not to damage the lower part which secures it to the door), unplug the wires, remove the inner cover (4 screws) to gain access to the solenoid. Remove the 4 screws on the solenoid replace with the new one, put the inner cover back in with the 4 screws that were previously removed, plug the wires back in and then replace the display cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kent from Bartlesville, OK
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JACOB from COLLEGEVILLE, PA
- Parts Used:
- WR62X23154
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Only crushed ice. No cubed.
Found a step by step video on YouTube made replacement very easy. Cubed ice is back. Time for a cocktail to celebrate!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Howard from Shelby Twp., MI
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Flap to ice dispenser would not close
I followed the video provided, and followed the advice of bill from cleveland hts. ohio, and did not have to remove the trim to access everything. The video made it so simple, a monkey could have learned how in 5 minutes. Thank you very much for all the help on this website. I will recommend it to all.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Colin from Saint Helena Island, SC
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Bad Solenoid Not Closing Ice Dispenser Door
Followed the on line video. Clear, concise & easy. Thanks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- james from apex, NC
- Parts Used:
- WR62X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
replaced the ice flap solenoid
I followed the instructions posted by previous custmers and they were accurate and simple
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Clifford from Goose Creek, SC
- Parts Used:
- WR62X10055
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Sticky ice maker chute door
The model we have, the front panel snaps into place. It was removed for access and the electrical connectors unplugged. Four screws and the chute assembly was removed. Removing three screws and opening the chute door allowed the solenoid assembly to be removed without removing the door assembly. All parts and area were cleaned and the assemmbly was the process in reverse.
Guideline to prolong recurrance: always put ice into glass first to reduce splashing of ice falling into liquids causing the solenoid armature to rust and stick.
Guideline to prolong recurrance: always put ice into glass first to reduce splashing of ice falling into liquids causing the solenoid armature to rust and stick.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- brian from Holland, OH
- Parts Used:
- WR17X10706, WR02X10585
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Ice door stuck open
The ice shute frosted up after the selonoid rusted. 1: Small flat screwdrvier to pop off control panel
2: phillips screwdriver to remove 4 screws to control backing plate.
3: Phillips screwdirver to remove seloniod and flap door.
4: replace selonoid, flap door, spring and crank door. Consider replacing screws due to rust.
I would replace all these parts at one time to save on shipping as any of them could cause the frosting. THe shipping is more than most parts! VERY EASY and QUICK!
2: phillips screwdriver to remove 4 screws to control backing plate.
3: Phillips screwdirver to remove seloniod and flap door.
4: replace selonoid, flap door, spring and crank door. Consider replacing screws due to rust.
I would replace all these parts at one time to save on shipping as any of them could cause the frosting. THe shipping is more than most parts! VERY EASY and QUICK!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from Elk Grove Vill, IL
- Parts Used:
- WR62X10055, WR02X10585
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Ice Dispenser Door Sticking Open
Removed access panel on freezer door, removed circuit board, removed and replaced solenoid, reinstalled previously removed parts
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Warren from Merrimack, NH
- Parts Used:
- WR62X10055
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Ice dispenser door not closing after dispensing ice
First remove trim surrounding ice/water dispenser assembly. Use a flat spackle knife to obtain space between door and trim. Be careful not t scratch refrigerator door. Then pry trim off. This was the most difficult part of repair. The front plate of the dispenser is held to the back of the dispenser by two friction fastners and in the case of my refrigerator a phillips screw (some don't have screw in middle). Use a small round tool like an allen wrench to push up on the 2 fastners to release them. Next push the front assembley aside and remove the 4 screws holding the back part of the dispenser. Push that assembly aside. Remove the defective solenoid assembly by removing the 3 mounting screws. The solenoid base can be worked out by slipping it out of the solenoid assembly plunger still attached to the dispenser door assembly. Next slide the plunger off of the dispenser door assembly. Install new solenoid assembly by reversing this procedure.
Hint - I found the ice door assembly (wr17x11653) also needed replacement and it is well worth the effort to replace both at the same time.
Hint - I found the ice door assembly (wr17x11653) also needed replacement and it is well worth the effort to replace both at the same time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Everett from Wylie, TX
- Parts Used:
- WR60X10185
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
whining noise from freezer
had to remove ice maker and several panels to get to the fan. wires for fan encapsulated so had to cut old and new wires then solder them together while working inside the small freezer area. not too bad all in all took about an hour to get it done. no more wind thru the trees noise and is working fine
Was this instruction helpful to you?
Thank you for voting!