dwight from phoenix, AZ
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
slow water flow in dispenser
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
14 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laura from Manchester, NH
Parts Used:
WR02X11330
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Somers Point, NJ
Parts Used:
WR23X10725
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Matty from CROTON HDSN, NY
Parts Used:
WR14X10305
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Door gaskets rippef
Removed old gaskets, replaced with new gaskets. Using my fingers.

I let the gaskets relax overnight before installing
6 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
M &M Aviation from ESCANABA, MI
Parts Used:
WR55X10025, WR02X10668, WR02X10647
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Refrigerator side freezing food
Replaced both temp sensors worked good for 2 days then began freezing food. Looked into it further on line. Found small motorized door broken that controls the cold air from the freezer
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Kalispell, MT
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Noisey evap motor
I tried to quite the noisey evap motor with special liquid motor grease from Radio Shack. It did not work, so I ordered the evap motor. My freezer motor was wired slightly different than the motor I received. The replacement motor had a male plug attached to the four wires, the original motor was different, so I cut the wires and spliced them into the original freezer wires (colors were the same). Remounted motor. Works great, and no more groaning motor
Peter
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Amy from Bryan, TX
Parts Used:
MWFP, WR02X11330
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
union connector leaking
replaced with new connector and it worked great. also replaced the water filter and that was super easy!
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from INDIANAPOLIS, IN
Parts Used:
WR49X10211
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
plastic wall support ports broken Door closing hard to not at all.
replaced divider wall. Removed shelf and drawers from freezer unit.
Removed old screws. Attached shelf rail to new divider wall and reinstall. A magnetic nut driver helped a bunch. Did not need to remove the door. Still concerned about design of part but that is not due to parts select but rather to GE. Really should have a metal support where screws go into the top of the freezer. attached to the divider wall This will probably break again same place. Caused by overloading drawers or shelf such that they pull on the horizontal support bar when opening. breaks the plastic screw support brackets. This provides for horizontal support of the divider wall as does a small hole in the horizontal bar. I reinforced that with a zip tie and a hole in the divider wall made with drill before installation. the fit of the plastic was sloppy on the bottom of the divider wall.
7 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bert from SAN JOSE, CA
Parts Used:
WR60X30922
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
INTERMITENT LOUD NOISE FROM EVAPORATOR FAN IN FREEZER
The repair did not go exactly the way it was described in the YouTube video, but basically it was similar. After unplugging the power cord, emptying the freezer, removing the shelves and the ice reservoir, I removed the ice maker assembly by unscrewing a Philips head screw and unplugging the power connector. The connector had little retaining tabs on each side that I pried open with a straight blade screwdriver. Then the ice maker lifted right out. Next I removed one screw holding the auger motor assembly, unplugged the power connector, and lifted out the assembly. This where things got difficult. After flailing around a bit, I removed the panel on the back wall of the freezer below the evaporator fan assembly, exposing the evaporator coil. I saw that the fan assembly was attached with two screws at the top and two screws at the bottom. The top screws were easily removed, but when I removed the bottom screws, which were situated in very tight quarters, I DROPPED BOTH SCREWS DOWN BEHIND THE EVAPORATOR COIL. Be prepared with a magnetic nutdriver so this doesn't happen to you. I could not retrieve the lost screws, but fortunately it appears that the top screws hold the assembly securely enough. The assembly was loose, but it was still attached by a power cord that I could not disconnect. I removed the tracks on the side walls for the ice bucket, and then I could maneuver the fan motor assembly just enough that I could reach over the top of it, grab and pull off the old fan blade, and slide the new fan blade onto the shaft. Reassembly was straightforward, replacing each part (except two lost screws) in reverse order to disassembly. After getting everything put back in and plugging in the power cord, I was amazed at how quiet it ran.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joseph from FARMINGVILLE, NY
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
refrigerator not cold
removed freezer door / shelf /ice maker pulled back panel off and removed fan
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from FRANKLIN SQ, NY
Parts Used:
WR23X10725
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
light not working
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Federal Way, AL
Parts Used:
WR23X10725
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Difficulty in removing the old switch
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around. If i had ordered the replacement before and not afterwards I would have seen this before hand.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from Crown Point, IN
Parts Used:
WR23X10725
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Refrigerator light wouldn't come on.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Marie from Philidelphia, PA
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
replace filter
just had to unscrew old one put the new one in
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Royce from Pasadena, TX
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Nothing to tell it was a replacement
Nothing to tell it was just a replacement part that the old part was removed and the new one inserted. Works like a dream Thanks
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!