Models > PFCE1NJYADSS > Instructions

PFCE1NJYADSS General Electric Refrigerator - Instructions

Jump to:

All Instructions for the PFCE1NJYADSS
106 - 120 of 250
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Deborah from BRADLEYVILLE, MO
Parts Used:
WR23X37285
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Broken light switch
This was so easy I think it took me 2 minutes. I am not very mechanically inclined but that didn't matter! Works perfect thank you!
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dan from COLUMBIA, SC
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from El Dorado, AR
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Bottom of refrigerator wouldn't coool
I removed the top vent and unplugged the ice machine ,took the back cover off the freezer.Removed the old fan which was pretty easy(unplugged it after I took the housing out for easy access) I plugged the new fan in and put everything back in the order I took off, and yada yada yada we have cooling.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Brentwood, CA
Parts Used:
WR60X10185
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Screw drivers, Wrench (Adjustable)
My son's Refrigerator
I started out replacing a bad thermostat, no problem,
when I hooked up the water, I found that the water resovior had a leak.
I replaced the resovior, easy fix, but I had to buy two 5/16 brass couplers.
then I found that the box would not get below 10 degrees, and the suction pressure was very low.
I figured that the fan motor was burned out, so I opened up the access covers, the fan motor was hanging there with broken mounts, so I replaced the motor, and repaired the mount.
Everything works great now, The parts shiping was very fast, I was impressed.
I thought I was going to get away without fixing everyones
HVAC problems when I retired.
Friends and family still remember that you are the HVAC man.
Tom
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Everett from Wylie, TX
Parts Used:
WR60X10185
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
whining noise from freezer
had to remove ice maker and several panels to get to the fan. wires for fan encapsulated so had to cut old and new wires then solder them together while working inside the small freezer area. not too bad all in all took about an hour to get it done. no more wind thru the trees noise and is working fine
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rene from Lancaster, CA
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Water flow from in-door dispenser was a trickle
We didn't think the dispenser problem was related to the filter - we were wrong! It took less than two minutes, including opening the box and unwrapping the filter. I'll definitely be changing my filter more often - and buying it through PartSelect. Your ordering was so easy and delivery was unbelievably fast!
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Hillary from MONTCLAIR, NJ
Parts Used:
WR02X11330
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Leaking from connector every time water was used
I watched the instructional video on this website and did everything that it said. There is no more leak when I use the in door water. Was as easy as it looks in the video and I am very happy!
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from DYERSBURG, TN
Parts Used:
WR17X22070
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Slow water flow from water dispenser.
Took out the MFW filter.
Screwed in the MFW bypass.
Dispensed several gallons of water.
Saw good flow of water.
Removed MFW bypass.
Replaced MFW filter.
Our water flow was back to normal.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Edward from Jenks, AL
Parts Used:
WR17X1948
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
ice maker pump and water line leaking
I replaced both the punp and water line. the website depicting the repair parts was the best i ever worked with. The parts were high quality delivered on time and easy to install. Total job cost $30 as opposed the cost of of a service man or a new refrig.
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kent from Bartlesville, OK
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Kingsport, TN
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Scheduled replacement
Turned the old filter loose, removed the adapter from it, put the adapter on the new filter and turned the new filter back into place.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from WEST HARTFORD, CT
Parts Used:
WR50X10069
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Temperature
I couldn’t repair the problem because the part that came did not have the clips to crimp on the end that go into the modular connection,
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William c.. from Barberton, OH
Parts Used:
MWFP
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
water leak
got new filter
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rose from Dorr, MI
Parts Used:
WR60X30922
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Broke the fan blade when replacing the Evaporator motor
Took cover off, pushed blade on, and replaced cover
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alan from Redmond, WA
Parts Used:
WR60X10185
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
The fan in the freezer was making a high pitched whining noise.
Unplugged the freezer. Then I gained access to the fan: remove the top freezer rack, remove the ice tray, remove the air flow manifold(needed to unscrew some screws), remove the manifold over the fan and cooling element. I unscrewed the fan mounting bracket. The fan motor's wires are plumbed through some plastic that i would have had to remove, so I decided instead to cut the wires and splice in the new fan motor. Then I put everything back together - the new motor works fine and doesn't make the whining noise.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PFCE1NJYADSS
106 - 120 of 250