- Customer:
- William from Harrington Park, NJ
- Parts Used:
- WR02X11666
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Rails on the lower pan frame snapped off.
There were no directions provided. Several pieces had to be removed from the broken frame and reinstalled on the new frame. Comparing the new frame to the old frame provided a road map for what parts had to reused and transferred. As all the parts are plactic, this had to be done carefully so as to avoid damaging the plastic during removal and installation. The only tool required was a screw driver which was used to pry the needed parts off the old frame.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Stephen from Spring, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
"Moaning Myrtle" syndrome. Refrigerator makes a whooing sound for hours at a time
Checked the internet for reports of similar problems and concluded that it was probably the main control board. Not being particularly handy, I would never have attempted to change the board myself if I had not read the comments and instructions from people on this site. Thanks.
The job was as straight forward as others have described. The only time I had a problem was pushing in the white tab to be able to pull the old board out. That was a bit of a fiddle.
The only thing I found different was the grounding wire. On the original board, this wire was at the bottom of the board and hooked into a wire that ran into the refrigerator. On the new board, the wire was at the top of the board and had a metal loop on it. If I understand it correctly, with the new grounding system the wire is pushed into the space above the board. Then when the back plate is reattached the metal loop makes contact with it , thus grounding the refrigerator.
I chose to run the grounding wire through the original wire into the refrigerator. That meant cutting off the metal loop, slicing in an extra piece of wire to connect the grounding wire on the board to the grounding wire into the refrigerator.
I also now use a surge suppressor for the refrigerator. The “Moaning Myrtle” syndrome started after Hurricane Ike. I suspect the surge when the power was restored damaged the control board. And as so many people seem to have this “Moaning Myrtle” problem, I suspect the control board has little or no surge protection.
The job was as straight forward as others have described. The only time I had a problem was pushing in the white tab to be able to pull the old board out. That was a bit of a fiddle.
The only thing I found different was the grounding wire. On the original board, this wire was at the bottom of the board and hooked into a wire that ran into the refrigerator. On the new board, the wire was at the top of the board and had a metal loop on it. If I understand it correctly, with the new grounding system the wire is pushed into the space above the board. Then when the back plate is reattached the metal loop makes contact with it , thus grounding the refrigerator.
I chose to run the grounding wire through the original wire into the refrigerator. That meant cutting off the metal loop, slicing in an extra piece of wire to connect the grounding wire on the board to the grounding wire into the refrigerator.
I also now use a surge suppressor for the refrigerator. The “Moaning Myrtle” syndrome started after Hurricane Ike. I suspect the surge when the power was restored damaged the control board. And as so many people seem to have this “Moaning Myrtle” problem, I suspect the control board has little or no surge protection.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Milford, UT
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
fridge wouldn't cool, frozen food thawed
First my wife and i took the panel off the back, unscrewed the old mainboard, unplugged all the switches from it and prayed that the new one would work. We were without a fridge for 2 weeks beginning 2 days before Christmas!!!!! Gingerly, we put the new board in place, screwed it into the fridge, connected the switches, attached the ground wire, and held our breath as we plugged it back in. Within seconds, the familiar sound of water filling the icemaker was hear and there were cheers all around!!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Leo from TWIN FALLS, ID
- Parts Used:
- 40A15
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Troy, NY
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
freezer and fridg would not hold the temp correctly. Getting too warm
I had Sears comre and check it out. They wanted $188. for the part and wanted $211 to put it in. They had the part in the truck. The fridg is a GE Profile and only 2 years old. Told them to forget it. Took me literally less than 10 minutes. They did a diagnostics, cost me $77. they told me the problem. I ordered the part here. It came in 3 days and the directions included were awesome. straight forward. Nice to know there is a place to go to avoid getting the shaft from appliance giants. Thank You !
The details: removed the 3 screws, took a picture of the board, didn't need it, unplugged the 6 plugs. pushed 3 clipds holding the board, unscrewed the ground, removed the board, lined up the 3 clips and snapped the new board in place, replugged the plugs and screwed in the ground. Plug the fridg in, done. Literally that easy.
The details: removed the 3 screws, took a picture of the board, didn't need it, unplugged the 6 plugs. pushed 3 clipds holding the board, unscrewed the ground, removed the board, lined up the 3 clips and snapped the new board in place, replugged the plugs and screwed in the ground. Plug the fridg in, done. Literally that easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Goshen, KY
- Parts Used:
- WR23X21444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Broken freezer light switch
Part arrived very fast as ordered..need to pry old switch out from top..use care to push the retainer down..after old switch was 1/2 out, I used a putty knife for better leveridge.Remove wire connector...after plugging in the wire connector to the replacement switch, make sure the switch is properly positioned so the switch will depress when door shuts.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Luther from Navarre, FL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers
Freezer thawing then re-freezing
The refrigerator was staying in defrost too long allowing the temperature to rise to the point that part of the ice (probably some of the food too) to melt then re-freeze. I first changed out the temp sensor and thermostat because I wanted to try the cheap stuff first but that didn't fix it, I should have gone with the mainboard first as it was the most likely cause. After putting in the new mainboard in the thing has worked perfectly since. The board was extremely easy to change, take the metal cover off with a nut driver. Carefully unplug the wires from old board and remove the board. The board is mounted on some plastic standoffs that expand after passing through the board, some of these came out while i was disconnecting the wires but some were there to stay until I figured out that I needed to squeeze the top of them to release the board. After getting the old board out just put the new one on the standoffs and connect the wires. Put the cover back on and DONE!
NOTES: The new board had some extra connectors that my old one did not, but the correct connectors were still in the old locations. The instructions that came with the board did talk about making some modifications to the refrigerator wiring on certain models, but that didn't apply to me. If I remember right the models requiring modification were all bottom freezer type. But even if you do have to do this the instrucions looked easy, just cut a couple of wires, no splicing or anything.
NOTES: The new board had some extra connectors that my old one did not, but the correct connectors were still in the old locations. The instructions that came with the board did talk about making some modifications to the refrigerator wiring on certain models, but that didn't apply to me. If I remember right the models requiring modification were all bottom freezer type. But even if you do have to do this the instrucions looked easy, just cut a couple of wires, no splicing or anything.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Redlands, CA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver
Motherboard burned out
I ordered the part on Sunday and had it by Tuesday. It only took a few minutes to install. Basically, I unplugged the unit and removed the cover over the motherboard with a nutdriver. The wires were easy to unplug and reinstall. There was no way to incorrectly install since they could only fit in the correct position. I reinstalled the panel pluged it back in and now the fridge is working great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Yulee, FL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
It started out with the door buttons not working and then the timer stopped working so it wouldn't allow the fan or the compressor to run replaced the board and everything started working
Took the three screws out of the cover, took the six plugs off of the board and removed board.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- mike from Aguilar, CO
- Parts Used:
- WR55X10025
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Linda from Montgomery, AL
- Parts Used:
- WR57X10033
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Leaking Valve on Ice Maker
I ordered the part and it got here very quickly. Being a novice home repair person, it took me awhile to get the courage to start. It was practically uneventful, but it did take some time to figure it out exactly. I did have to bend the piece some, which is always a little nerve wracking. However, the part is working beautifully and I feel good about myself.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from Chicago, IL
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Water under refrigerator, leaky ice maker water supply solenoid valve
This is a relatively simple repair, but requires a bit of running around your house and sitting in a likely cramped space on the floor behind your refrigerator. These steps assume you have verified the valve is leaking and not the lines. 1. Locate where the water line to the fridge connects to the house plumbing. Close the next valve in the house plumbing upstream of this connection. Open some fixture (likely the cold on the kitchen sink) to relieve water pressure in this section of plumbing. Water should flow briefly, then dribble and stop on its own. 2. Unplug your fridge. There are moving parts (a fan) close to the valve that may injure you while you are working. 3. Pull your fridge away from the wall enough so you can scoot behind and sit behind. 4. Gather your tools and parts and squeeze behind the fridge. 5. Remove the felt paper dust cover. Carefully collect the screws. 6. Take a picture of the electrical connection to the valve or make a mental note. 7. Carefully unclip lines from the fridge and remove screws holding valve to fridge body. Slicing a line will create a new problem to fix. Carefully collect the screws. 8. Remove electrical connection. Grasp the connector and pull firmly. Do not yank the wires. 9. Over the bucket, disconnect old valve from lines. Some residual water will flow out. If the stream is steady, double check that Step 1 is completed correctly. Set old valve aside. 10. Examine new valve to determine water input and outlet. There may be an arrow indicating flow direction. 11. Seat the input line in the valve input firmly and connect. Mine was a nut I tightened with a small crescent wrench. 12. Seat the outlet line in the valve outlet firmly and connect. Mine was a push in quick connect. 14. Rest the valve over the bucket. Get up and turn the water back on. Verify your connections are not leaking. 15. Review your picture and reconnect the electrical connection. 16. Install the new valve onto the fridge body. Mine was a different geometry that required some gentle bending of the mounting bracket. Reclip lines to fridge. 17. While you're down there, vacuum underneath your fridge. 18. Reinstall felt paper dust cover. 19. Plug fridge back in. Clean up. 20. Monitor your ice maker, verify good operation. When satisfied, push fridge back. Recycle(?) old valve. 21. Success!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Pamela from Whitesboro, NY
- Parts Used:
- WR17X11586
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
door bin was cracked
took out old door bin & put in new door bin
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Boca Raton, FL
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Difficult
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Ice Dispenser not working
As it turned out much of the electronics is driven by 13.5 volts off the Main Control Board. The Ice Dispenser caused the problem because it over currented the depleted board power. You could hear a clicking noise from the board which was the main relay short cycling and not staying energized. While waiting for the replacement board I unpluged the condenser fan which is a DC motor and uses the Board power. In place of that fan I use a small table top fan to keep the condenser cool. As it turned out I only needed it for 3 days because Parts Select did a super quick job of delivering the new board. Thanks for the super service!!!!!! Removal of the board only required unpluging the electrical connections squezing the retaining board pins with pliers and pulling the board out, pushing on the new board and connecting the electrical plugs. If the board locks like mine did, just unplug the main board power plug, let the memory clear and replug the power plug. The unit should then start and run with no problems.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kirk E from GRASS VALLEY, CA
- Parts Used:
- WR55X24064
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor.
Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I searched and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I searched and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.