Refigerator quit running
Removed back cover from unit. unpluged wirring harness installed new control board and refigerator runs lik new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joseph from Marrero, LA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Main Board failed
Part arrived 2 days before anticipated. I was able to keep my fridge running long enough to get the new part in, which took no time at all. The Main Board relay would start clicking and the compressor would shut down. By unplugging the top right plug for a minute and plugging it back in I was able to keep it running for a few hours at a time. Good enough to keep my food from going bad. Thr part was an easy plug in replacement, was a good price, and works great.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Rich from san marcos, CA
- Parts Used:
- WR23X21444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
No ice from door, but did have water
I got the wrong switch before so just need to put the right 1 in. Super easy, pop off old, plug in new, click back into place. Done. REALLY REALLY EASY for anyone to do
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Greg from Damon, TX
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Fan was not running to circulate the air; found resistors burned on main board
Removed the board cover from the back, removed old board, installed new board, installed cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Phyllis from Minneapolis, MN
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
ice maker was leaking
thats what I did is remove the teo screws and took the old single outlet valve out. And put the new one in and put the screws back in. First turned off the water and put the water back on after I was threw and no leaks.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- jaime from SYLMAR, CA
- Parts Used:
- WR55X10942C
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
No Cooling on either freezer or refrigerator
Everything seemed to be working right, but no cooling, so I tried turning on and off the switch that turns the light on 5 times within two seconds, refrigerator did not shot. so I removed the main board and I notice a short had taken place on one of the relay legs. I ordered the main board and replaced it. The main board is on the back of the freezer covered with a sheet metal panel about 8"x8" and is secured with hex sheet metal screws. Everything is working now. Please make sure to unplug the unit from power before removing the main board.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from WINTERVILLE, GA
- Parts Used:
- 40A15
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
lights blown out
replaced lights in refrigirator and freezer
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Norma from NEWPORT NEWS, VA
- Parts Used:
- WR30X10050
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The shelf was broken and the ice tray would not go all the way in.
I took out the broken shelf and slid in the new one. No tools took all of 15 seconds.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barbara from NEW LONDON, CT
- Parts Used:
- WR14X10177
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
A broken freezer door gasket
Removed the old gasket, cleaned off any residue and snapped the new gasket into the track and easy! The longest time was taking the freezer door off.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Doug from COPE, CO
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Refridgerator stopped making ice
Removed the old water valve from back of refrigerator by using a screwdriver. Pulled water line off old valve that runs into the fridge and inserted it into the new part. I used a pair of pliers to take off water line that runs into the water valve from the house. Screwed the water line back onto the new valve. Took about 10 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cliff from ROCKVILLE, VA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Wrench set
The old solenoid was slow to shut off causing the icemaker to overfill.
Unplug refrigerator and turn water supply off to the ice maker. Remove the screws holding the bottom cardboard-like cover from the lower back of the refrigerator. Remove the water supply line to the old solenoid with 1/2 inch wrench. Unplug the two power supply wires to the old solenoid. Remove the screw that holds the solenoid to the back panel of the unit. After the solenoid is pulled out, remove the output hose with a 1/2 inch wrench. The configuration of the replacement solenoid is likely a little different than the original, but it seems to be rather universal and will fit back into place and perform properly. The new solenoid does not use a compression type nut to secure the output line. It's just a simple push-in connection. The wires may have to be rerouted a little, just keep them clear of the evaporator fan blades Reverse the removal procedure and you're done.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randall from Cumming, GA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Wrench set
Water valve for ice maker leaking
Other than having to bend the bracket 90 degrees it was an easy install.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Margaret from Virginia Beach, VA
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers
Ice maker would only make very small and very few ice cubes.
After determining that the ice maker on this relatively new refrigerator would make ice cubes if it received the proper amount of water. Ordered the valve and received in a couple days. Using a nut driver, removed the cardboard cover from the back of the refrigerator. Removed one screw holding the valve bracket to the fridge and removed another screw holding the water supply line and the water line to the ice maker in place. Pulled plug on fridge and removed 2 wires from valve. Removed inlet and outlet lines from old valve and reversed the process installing the new valve.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Mark from ROSEMOUNT, MN
- Parts Used:
- WR55X10025
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Donald from Jacksonville, FL
- Parts Used:
- WR57X10033
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Ice Maker Did Not Work
Tried replacing water valve since no water in ice cube tray. Exact part not available due to age of refrigerator, but I got the equivalent replacement part for $18. Mounting holes different, but I made it work. Also one connect on new one slip connect whereas both compression fittings on old valve. I put it back together and icemaker now works great.
Was this instruction helpful to you?
Thank you for voting!