Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Phillip from Springfield, VA
Parts Used:
WR17X11653
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Ice chute frosted up
Procedure for Replacing the Ice Chute Plate
1. Turn off the power.
2. Snap off the outside trim ring. Use a plastic screwdriver to avoid scratching the cabinet.
3. Locate the three small holes below the control panel facing, just above ice chute. The center hole is not used. With a small, blunt, object (wire – blunted nail) that is slightly smaller than the holes, push up rather firmly up through the outer holes to release front control panel.
4. Remove the three wire connectors from printed circuit board. Firmly pull/pry them straight out of retaining clip. Use caution: Excessive force will break clips.
5. Release the secondary panel by removing four screws (one in each corner).
6. Remove the flap assembly.
7. Clean all accessible areas with 1/10 bleach water to sanitize. Rinse the cleaned area with clear water and thoroughly dry everything before re-assembling the panel.
8. Install the new flap assembly.
9. Re-installed everything in the reverse order and check the functionality.
10. Order a spare ice chute flapper to be ready for the next event.
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Amanda from HUMBLE, TX
Parts Used:
WR50X10065
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Fridge was hot and freezer was still cool
Watched a parts.com video on how to change defrost thermostat and followed the instructions
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from Elkridge, MD
Parts Used:
WR17X11653
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Ice Flapper warped and clogged up the Ice Shoot
I bought a Flapper replacement part from Parts Select. I installed it following their very complete on-line video directions. Their complete and easy to follow directions made my job very easy, and the work was completed without any problems and just as good as if it were done by a professional repair person. I am proud of my work, it couldn't have been done without their video insructions. Also I got delivery of the part within two days of my order. I will alway look for Parts Select any time I need an applicance repaired. Thanks to Parts Select!
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Clifton, VA
Parts Used:
WR32X26198
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Broken Drawer
All I had to do was slide it in. But that's not what made me so thrilled with your site. What won my devotion was your site's ease of use (I couldn't find what I was looking for on GE's site) and the promptness of delivery. I will certainly use you again and recommend your services to my friends!
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from Anaheim, CA
Parts Used:
WR29X10085
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
piece broke off on stripper causing ice to jam
tab on right top, flat insert on left. Pull up, toward you and to the right. It pops off. No tools needed.
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sharon from PEORIA, AZ
Parts Used:
WR12X10625
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
broken plastic freezer shelf front.
Emptyed shelf of food. Aligned new plastic front piece. Pressed front. Went right into place.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joe from PITTSBURGH, PA
Parts Used:
MSWF
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Water Filter Replacement
GE Side by Side Refrigerator Water Filter Replacement
1. The trick is to purchase the correct Filter.
2. We use GE MSWF, some filters just don’t fit.
3. The “RESET FILTER” will light when the filter needs replaced.
4. Remove the old filter and throw away.
5. Insert the new filter, turn ¼ turn to the right.
6. Get a tall glass, set “WATER”.
7. Dump water in the sink, repeat, flush for 5 minutes.
8. Hold “RESET FILTER” button for 3 seconds to reset.
9. Enjoy!
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
clyde from RIALTO, CA
Parts Used:
WR60X24484, WR60X10209
Difficulty Level:
Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
freezer drop temp to 12 degrees.recommended temp zero.
Replace the motor fan on condenser and clean the condenser
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Lawerence, MI
Parts Used:
WR17X11505
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Ice would fall after removing glass.
I took the ice drawer out and turned it upside down. Then removed two philips screws holding the drawer front on. Then with a small straight edge screwdriver pry out the sides to release the locking tabs and remove the auger and crusher assembly. Then on the end of the auger remove the e-clip, slide the auger out and remove the broken part of the crusher dispenser and replace with new. Easier than it sounds. Parts Select was great to deal with. Had my parts in two days.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Centennial, AL
Parts Used:
WR23X31507
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light switch broke when I dropped a jar of jam on it.
The three bulbs would then remain on, so I loosened them to keep them off. I didn't know that the cooling system also would stop when the door was open, so for two days only the side freezer was operational. When I discovered that, I hot glued the switch button off, while I searched for a replacement part. The replacement part was an exact duplicate. A simple prying out of the old switch - using a screwdriver, and the reconnection of the two wires connectors to the new part, and clicking back in place ... done. Seriously, it took two minutes.
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
George from Sugar Hill, GA
Parts Used:
WR12X10625
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
broken handle
Handle just snaps on.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bert from SAN JOSE, CA
Parts Used:
WR60X30922
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
INTERMITENT LOUD NOISE FROM EVAPORATOR FAN IN FREEZER
The repair did not go exactly the way it was described in the YouTube video, but basically it was similar. After unplugging the power cord, emptying the freezer, removing the shelves and the ice reservoir, I removed the ice maker assembly by unscrewing a Philips head screw and unplugging the power connector. The connector had little retaining tabs on each side that I pried open with a straight blade screwdriver. Then the ice maker lifted right out. Next I removed one screw holding the auger motor assembly, unplugged the power connector, and lifted out the assembly. This where things got difficult. After flailing around a bit, I removed the panel on the back wall of the freezer below the evaporator fan assembly, exposing the evaporator coil. I saw that the fan assembly was attached with two screws at the top and two screws at the bottom. The top screws were easily removed, but when I removed the bottom screws, which were situated in very tight quarters, I DROPPED BOTH SCREWS DOWN BEHIND THE EVAPORATOR COIL. Be prepared with a magnetic nutdriver so this doesn't happen to you. I could not retrieve the lost screws, but fortunately it appears that the top screws hold the assembly securely enough. The assembly was loose, but it was still attached by a power cord that I could not disconnect. I removed the tracks on the side walls for the ice bucket, and then I could maneuver the fan motor assembly just enough that I could reach over the top of it, grab and pull off the old fan blade, and slide the new fan blade onto the shaft. Reassembly was straightforward, replacing each part (except two lost screws) in reverse order to disassembly. After getting everything put back in and plugging in the power cord, I was amazed at how quiet it ran.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Barry from Miami, FL
Parts Used:
WR17X11459
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Broken cup drive
I disassymbled the cover bucket bottom from the bucket ice dispenser then found that the auger helix dispenser had broke thru the bucket. It seems the auger nut got cross threaded, this provided a problem to remove the auger. the only way to remove because the nut was wedged was to cut thru the bucket to the auger. The easy part was replacing the cup drive which was the problem along with the auger nut.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mike from hatboro, PA
Parts Used:
WR62X10055, WR17X11653, WR23X10783, WR17X10706, WR02X10585
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Flapper is stuck open
There are three holes under the front panel in which you push a very small screwdriver in and the front panel comes off.In back of the panel is another panel with 4 screws .1 at each corner.Remove the 4 screws and that will come off exposing the working parts that need to be replaced.This is also a good time to clean anything you can get to in that area.It is very important to remember how everything came out.
6 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
charles from SCOTTSDALE, AZ
Parts Used:
WR55X10025
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Defrost not working coil iced up
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!